Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy

7 p.

Autores:
Quintero, Jorge Eduardo
Manotas, Gioanny Francisco
Galeano, Yuber Alejandro
Tellez, Diego Mauricio
Tipo de recurso:
Article of journal
Fecha de publicación:
2014
Institución:
Universidad de Santander
Repositorio:
Repositorio Universidad de Santander
Idioma:
eng
OAI Identifier:
oai:repositorio.udes.edu.co:001/3577
Acceso en línea:
https://repositorio.udes.edu.co/handle/001/3577
Palabra clave:
Faradic currents
Electrotherapy
Neuromuscular stimulation
Facial palsy
Biphasic pulses
Corrientes farádicas
Electroterapia
Estimulación neuromuscular
Parálisis facial
Pulsos bifásico
Rights
openAccess
License
Derechos Reservados - Universidad de Santander, 2014
id RUDES2_916c20d3449a4d37d53fa7ec5c035425
oai_identifier_str oai:repositorio.udes.edu.co:001/3577
network_acronym_str RUDES2
network_name_str Repositorio Universidad de Santander
repository_id_str
dc.title.eng.fl_str_mv Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy
dc.title.alternative.spa.fl_str_mv Diseño y desarrollo de un equipo de estimulación eléctrica transcutánea para rehabilitación neuromuscular en personas con parálisis facial
title Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy
spellingShingle Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy
Faradic currents
Electrotherapy
Neuromuscular stimulation
Facial palsy
Biphasic pulses
Corrientes farádicas
Electroterapia
Estimulación neuromuscular
Parálisis facial
Pulsos bifásico
title_short Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy
title_full Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy
title_fullStr Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy
title_full_unstemmed Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy
title_sort Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy
dc.creator.fl_str_mv Quintero, Jorge Eduardo
Manotas, Gioanny Francisco
Galeano, Yuber Alejandro
Tellez, Diego Mauricio
dc.contributor.author.spa.fl_str_mv Quintero, Jorge Eduardo
Manotas, Gioanny Francisco
Galeano, Yuber Alejandro
Tellez, Diego Mauricio
dc.subject.proposal.eng.fl_str_mv Faradic currents
Electrotherapy
Neuromuscular stimulation
Facial palsy
Biphasic pulses
topic Faradic currents
Electrotherapy
Neuromuscular stimulation
Facial palsy
Biphasic pulses
Corrientes farádicas
Electroterapia
Estimulación neuromuscular
Parálisis facial
Pulsos bifásico
dc.subject.proposal.spa.fl_str_mv Corrientes farádicas
Electroterapia
Estimulación neuromuscular
Parálisis facial
Pulsos bifásico
description 7 p.
publishDate 2014
dc.date.issued.spa.fl_str_mv 2014-07-30
dc.date.accessioned.spa.fl_str_mv 2019-08-14T13:39:14Z
dc.date.available.spa.fl_str_mv 2019-08-14T13:39:14Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.content.spa.fl_str_mv Text
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.doi.eng.fl_str_mv 10.18180/tecciencia.2014.16.4
dc.identifier.issn.spa.fl_str_mv 2422-3670
1909-3667
dc.identifier.uri.spa.fl_str_mv https://repositorio.udes.edu.co/handle/001/3577
identifier_str_mv 10.18180/tecciencia.2014.16.4
2422-3670
1909-3667
url https://repositorio.udes.edu.co/handle/001/3577
dc.language.iso.spa.fl_str_mv eng
language eng
dc.relation.ispartof.spa.fl_str_mv Tecciencia
dc.relation.ispartofseries.spa.fl_str_mv Tecciencia;Vol 9, No 16, 2014
Revista ESAICA;Vol. 1 Núm. 1 (2015)
dc.rights.spa.fl_str_mv Derechos Reservados - Universidad de Santander, 2014
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.creativecommons.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)
dc.rights.uri.spa.fl_str_mv https://creativecommons.org/licenses/by-nc/4.0/
rights_invalid_str_mv Derechos Reservados - Universidad de Santander, 2014
Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)
https://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.source.eng.fl_str_mv http://www.scielo.org.co/pdf/tecci/v9n16/v9n16a05.pdf
https://revistas.udes.edu.co/esaica/article/view/265
institution Universidad de Santander
bitstream.url.fl_str_mv https://repositorio.udes.edu.co/bitstreams/b12f1a08-1ec3-4a7c-a664-132a7e109d31/download
https://repositorio.udes.edu.co/bitstreams/7b0475e0-8d61-4f51-9952-2b6fa2d61132/download
https://repositorio.udes.edu.co/bitstreams/de9df63c-a3aa-46a9-b2d6-dd07c9c9fbd8/download
https://repositorio.udes.edu.co/bitstreams/28e517db-1289-4202-8500-631db07e2d78/download
https://repositorio.udes.edu.co/bitstreams/bf0fadbb-bc91-408d-b7f5-eccd17d77f31/download
https://repositorio.udes.edu.co/bitstreams/cdfa8213-9be9-473f-adb3-25954f9b8140/download
bitstream.checksum.fl_str_mv 5759dcb2a000131d1dfe0261a36cee9a
38d94cf55aa1bf2dac1a736ac45c881c
a3f963df15dc594f382309fd3ed716a6
1c64cc82b99ee295099fd004f1bb6026
3fe9c51536286d5f577317bf9a1d8bc2
10f2d332417d7c869e8deb82222cfbfd
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Universidad de Santander
repository.mail.fl_str_mv soporte@metabiblioteca.com
_version_ 1808490856763621376
spelling Quintero, Jorge Eduardof3cfc11f-6a67-4099-85c2-9b8c0902443a-1Manotas, Gioanny Francisco02658e41-72f7-433b-8e95-17a1e9f3c943-1Galeano, Yuber Alejandro091d4e58-aadb-4c76-ba9d-7e265bc37120-1Tellez, Diego Mauriciocf854428-8a34-4125-8b08-75174ddcc754-12019-08-14T13:39:14Z2019-08-14T13:39:14Z2014-07-307 p.Peripheral facial palsy is a relatively common pathology that is usually unilateral. Multiple causes generate it, producing aesthetic and functional deformity, as well as emotional, social, and professional alterations. We developed electronic equipment for transcutaneous electric stimulation, which will be applied in neuromuscular rehabilitation treatments of individuals who have suffered peripheral facial palsy. Electrotherapeutic energy is generated through current sources, whose waveforms consist of rectangular biphasic pulses, which can be adjusted in their duration or width, frequency, and intensity. For patient electrical safety, the equipment is powered with batteries. The waveforms generated and the therapeutic parameters are controlled through a microcontroller. What differentiates this equipment from the few found in the market, for this rather specific application, is that it was designed with four independent channels for passive therapy, which permits stimulating more than one neuromuscular package at the same time, and also has one channel for active therapy, which is dynamically applied by the therapist by moving the active electrode over the surface of the face.La parálisis facial periférica es una patología relativamente frecuente que habitualmente es unilateral. Las causas que la generan son múltiples, produciendo una deformidad estética y funcional, así como alteraciones emocionales, sociales y profesionales. Se ha desarrollado un equipo electrónico de estimulación eléctrica transcutánea, que se aplicará en tratamientos de rehabilitación neuromuscular de personas que han sufrido parálisis facial periférica. La energía electroterapéutica se genera mediante fuentes de corriente, cuyas formas de onda consisten en pulsos bifásicos rectangulares, a los cuales se les puede ajustar la duración o ancho del mismo, la frecuencia y la intensidad. Por seguridad eléctrica para el paciente el equipo se alimenta con baterías. Las formas de onda que se generan y los parámetros terapéuticos se controlan mediante un microcontrolador. Lo que diferencia a este equipo de los pocos que se encuentran en el mercado, para esta aplicación tan específica, es que se diseñó con cuatro canales independientes para terapia pasiva, permitiéndole estimular más de un paquete neuromuscular al mismo tiempo, y dispone también de un canal para terapia activa, que lo aplica dinámicamente el terapeuta al mover el electrodo activo por la superficie de la cara.application/pdf10.18180/tecciencia.2014.16.42422-36701909-3667https://repositorio.udes.edu.co/handle/001/3577engTeccienciaTecciencia;Vol 9, No 16, 2014Revista ESAICA;Vol. 1 Núm. 1 (2015)Derechos Reservados - Universidad de Santander, 2014info:eu-repo/semantics/openAccessAtribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)https://creativecommons.org/licenses/by-nc/4.0/http://purl.org/coar/access_right/c_abf2http://www.scielo.org.co/pdf/tecci/v9n16/v9n16a05.pdfhttps://revistas.udes.edu.co/esaica/article/view/265Faradic currentsElectrotherapyNeuromuscular stimulationFacial palsyBiphasic pulsesCorrientes farádicasElectroterapiaEstimulación neuromuscularParálisis facialPulsos bifásicoDesign and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsyDiseño y desarrollo de un equipo de estimulación eléctrica transcutánea para rehabilitación neuromuscular en personas con parálisis facialArtículo de revistahttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1Textinfo:eu-repo/semantics/articlehttp://purl.org/redcol/resource_type/ARTinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/version/c_970fb48d4fbd8a85PublicationORIGINALDesign and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy.pdfDesign and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy.pdfapplication/pdf468345https://repositorio.udes.edu.co/bitstreams/b12f1a08-1ec3-4a7c-a664-132a7e109d31/download5759dcb2a000131d1dfe0261a36cee9aMD58LICENSElicense.txtlicense.txttext/plain; charset=utf-859https://repositorio.udes.edu.co/bitstreams/7b0475e0-8d61-4f51-9952-2b6fa2d61132/download38d94cf55aa1bf2dac1a736ac45c881cMD53TEXTDiseño y desarrollo de un equipo de estimulación eléctrica transcutanea para rehabilitación neuromuscular en personas con parálisis facial.pdf.txtDiseño y desarrollo de un equipo de estimulación eléctrica transcutanea para rehabilitación neuromuscular en personas con parálisis facial.pdf.txtExtracted texttext/plain19093https://repositorio.udes.edu.co/bitstreams/de9df63c-a3aa-46a9-b2d6-dd07c9c9fbd8/downloada3f963df15dc594f382309fd3ed716a6MD54Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy.pdf.txtDesign and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy.pdf.txtExtracted texttext/plain22939https://repositorio.udes.edu.co/bitstreams/28e517db-1289-4202-8500-631db07e2d78/download1c64cc82b99ee295099fd004f1bb6026MD56THUMBNAILDiseño y desarrollo de un equipo de estimulación eléctrica transcutanea para rehabilitación neuromuscular en personas con parálisis facial.pdf.jpgDiseño y desarrollo de un equipo de estimulación eléctrica transcutanea para rehabilitación neuromuscular en personas con parálisis facial.pdf.jpgGenerated Thumbnailimage/jpeg2033https://repositorio.udes.edu.co/bitstreams/bf0fadbb-bc91-408d-b7f5-eccd17d77f31/download3fe9c51536286d5f577317bf9a1d8bc2MD55Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy.pdf.jpgDesign and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy.pdf.jpgGenerated Thumbnailimage/jpeg1958https://repositorio.udes.edu.co/bitstreams/cdfa8213-9be9-473f-adb3-25954f9b8140/download10f2d332417d7c869e8deb82222cfbfdMD57001/3577oai:repositorio.udes.edu.co:001/35772023-10-11 13:22:24.347https://creativecommons.org/licenses/by-nc/4.0/Derechos Reservados - Universidad de Santander, 2014https://repositorio.udes.edu.coRepositorio Universidad de Santandersoporte@metabiblioteca.comTGljZW5jaWEgZGUgUHVibGljYWNpw7NuIFVERVMKRGlyZWN0cmljZXMgZGUgVVNPIHkgQUNDRVNPCgo=