Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy
7 p.
- Autores:
-
Quintero, Jorge Eduardo
Manotas, Gioanny Francisco
Galeano, Yuber Alejandro
Tellez, Diego Mauricio
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2014
- Institución:
- Universidad de Santander
- Repositorio:
- Repositorio Universidad de Santander
- Idioma:
- eng
- OAI Identifier:
- oai:repositorio.udes.edu.co:001/3577
- Acceso en línea:
- https://repositorio.udes.edu.co/handle/001/3577
- Palabra clave:
- Faradic currents
Electrotherapy
Neuromuscular stimulation
Facial palsy
Biphasic pulses
Corrientes farádicas
Electroterapia
Estimulación neuromuscular
Parálisis facial
Pulsos bifásico
- Rights
- openAccess
- License
- Derechos Reservados - Universidad de Santander, 2014
id |
RUDES2_916c20d3449a4d37d53fa7ec5c035425 |
---|---|
oai_identifier_str |
oai:repositorio.udes.edu.co:001/3577 |
network_acronym_str |
RUDES2 |
network_name_str |
Repositorio Universidad de Santander |
repository_id_str |
|
dc.title.eng.fl_str_mv |
Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy |
dc.title.alternative.spa.fl_str_mv |
Diseño y desarrollo de un equipo de estimulación eléctrica transcutánea para rehabilitación neuromuscular en personas con parálisis facial |
title |
Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy |
spellingShingle |
Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy Faradic currents Electrotherapy Neuromuscular stimulation Facial palsy Biphasic pulses Corrientes farádicas Electroterapia Estimulación neuromuscular Parálisis facial Pulsos bifásico |
title_short |
Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy |
title_full |
Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy |
title_fullStr |
Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy |
title_full_unstemmed |
Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy |
title_sort |
Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy |
dc.creator.fl_str_mv |
Quintero, Jorge Eduardo Manotas, Gioanny Francisco Galeano, Yuber Alejandro Tellez, Diego Mauricio |
dc.contributor.author.spa.fl_str_mv |
Quintero, Jorge Eduardo Manotas, Gioanny Francisco Galeano, Yuber Alejandro Tellez, Diego Mauricio |
dc.subject.proposal.eng.fl_str_mv |
Faradic currents Electrotherapy Neuromuscular stimulation Facial palsy Biphasic pulses |
topic |
Faradic currents Electrotherapy Neuromuscular stimulation Facial palsy Biphasic pulses Corrientes farádicas Electroterapia Estimulación neuromuscular Parálisis facial Pulsos bifásico |
dc.subject.proposal.spa.fl_str_mv |
Corrientes farádicas Electroterapia Estimulación neuromuscular Parálisis facial Pulsos bifásico |
description |
7 p. |
publishDate |
2014 |
dc.date.issued.spa.fl_str_mv |
2014-07-30 |
dc.date.accessioned.spa.fl_str_mv |
2019-08-14T13:39:14Z |
dc.date.available.spa.fl_str_mv |
2019-08-14T13:39:14Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.coarversion.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.doi.eng.fl_str_mv |
10.18180/tecciencia.2014.16.4 |
dc.identifier.issn.spa.fl_str_mv |
2422-3670 1909-3667 |
dc.identifier.uri.spa.fl_str_mv |
https://repositorio.udes.edu.co/handle/001/3577 |
identifier_str_mv |
10.18180/tecciencia.2014.16.4 2422-3670 1909-3667 |
url |
https://repositorio.udes.edu.co/handle/001/3577 |
dc.language.iso.spa.fl_str_mv |
eng |
language |
eng |
dc.relation.ispartof.spa.fl_str_mv |
Tecciencia |
dc.relation.ispartofseries.spa.fl_str_mv |
Tecciencia;Vol 9, No 16, 2014 Revista ESAICA;Vol. 1 Núm. 1 (2015) |
dc.rights.spa.fl_str_mv |
Derechos Reservados - Universidad de Santander, 2014 |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.creativecommons.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0) |
dc.rights.uri.spa.fl_str_mv |
https://creativecommons.org/licenses/by-nc/4.0/ |
rights_invalid_str_mv |
Derechos Reservados - Universidad de Santander, 2014 Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0) https://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.source.eng.fl_str_mv |
http://www.scielo.org.co/pdf/tecci/v9n16/v9n16a05.pdf https://revistas.udes.edu.co/esaica/article/view/265 |
institution |
Universidad de Santander |
bitstream.url.fl_str_mv |
https://repositorio.udes.edu.co/bitstreams/b12f1a08-1ec3-4a7c-a664-132a7e109d31/download https://repositorio.udes.edu.co/bitstreams/7b0475e0-8d61-4f51-9952-2b6fa2d61132/download https://repositorio.udes.edu.co/bitstreams/de9df63c-a3aa-46a9-b2d6-dd07c9c9fbd8/download https://repositorio.udes.edu.co/bitstreams/28e517db-1289-4202-8500-631db07e2d78/download https://repositorio.udes.edu.co/bitstreams/bf0fadbb-bc91-408d-b7f5-eccd17d77f31/download https://repositorio.udes.edu.co/bitstreams/cdfa8213-9be9-473f-adb3-25954f9b8140/download |
bitstream.checksum.fl_str_mv |
5759dcb2a000131d1dfe0261a36cee9a 38d94cf55aa1bf2dac1a736ac45c881c a3f963df15dc594f382309fd3ed716a6 1c64cc82b99ee295099fd004f1bb6026 3fe9c51536286d5f577317bf9a1d8bc2 10f2d332417d7c869e8deb82222cfbfd |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Universidad de Santander |
repository.mail.fl_str_mv |
soporte@metabiblioteca.com |
_version_ |
1818101397477916672 |
spelling |
Quintero, Jorge Eduardof3cfc11f-6a67-4099-85c2-9b8c0902443a-1Manotas, Gioanny Francisco02658e41-72f7-433b-8e95-17a1e9f3c943-1Galeano, Yuber Alejandro091d4e58-aadb-4c76-ba9d-7e265bc37120-1Tellez, Diego Mauriciocf854428-8a34-4125-8b08-75174ddcc754-12019-08-14T13:39:14Z2019-08-14T13:39:14Z2014-07-307 p.Peripheral facial palsy is a relatively common pathology that is usually unilateral. Multiple causes generate it, producing aesthetic and functional deformity, as well as emotional, social, and professional alterations. We developed electronic equipment for transcutaneous electric stimulation, which will be applied in neuromuscular rehabilitation treatments of individuals who have suffered peripheral facial palsy. Electrotherapeutic energy is generated through current sources, whose waveforms consist of rectangular biphasic pulses, which can be adjusted in their duration or width, frequency, and intensity. For patient electrical safety, the equipment is powered with batteries. The waveforms generated and the therapeutic parameters are controlled through a microcontroller. What differentiates this equipment from the few found in the market, for this rather specific application, is that it was designed with four independent channels for passive therapy, which permits stimulating more than one neuromuscular package at the same time, and also has one channel for active therapy, which is dynamically applied by the therapist by moving the active electrode over the surface of the face.La parálisis facial periférica es una patología relativamente frecuente que habitualmente es unilateral. Las causas que la generan son múltiples, produciendo una deformidad estética y funcional, así como alteraciones emocionales, sociales y profesionales. Se ha desarrollado un equipo electrónico de estimulación eléctrica transcutánea, que se aplicará en tratamientos de rehabilitación neuromuscular de personas que han sufrido parálisis facial periférica. La energía electroterapéutica se genera mediante fuentes de corriente, cuyas formas de onda consisten en pulsos bifásicos rectangulares, a los cuales se les puede ajustar la duración o ancho del mismo, la frecuencia y la intensidad. Por seguridad eléctrica para el paciente el equipo se alimenta con baterías. Las formas de onda que se generan y los parámetros terapéuticos se controlan mediante un microcontrolador. Lo que diferencia a este equipo de los pocos que se encuentran en el mercado, para esta aplicación tan específica, es que se diseñó con cuatro canales independientes para terapia pasiva, permitiéndole estimular más de un paquete neuromuscular al mismo tiempo, y dispone también de un canal para terapia activa, que lo aplica dinámicamente el terapeuta al mover el electrodo activo por la superficie de la cara.application/pdf10.18180/tecciencia.2014.16.42422-36701909-3667https://repositorio.udes.edu.co/handle/001/3577engTeccienciaTecciencia;Vol 9, No 16, 2014Revista ESAICA;Vol. 1 Núm. 1 (2015)Derechos Reservados - Universidad de Santander, 2014info:eu-repo/semantics/openAccessAtribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)https://creativecommons.org/licenses/by-nc/4.0/http://purl.org/coar/access_right/c_abf2http://www.scielo.org.co/pdf/tecci/v9n16/v9n16a05.pdfhttps://revistas.udes.edu.co/esaica/article/view/265Faradic currentsElectrotherapyNeuromuscular stimulationFacial palsyBiphasic pulsesCorrientes farádicasElectroterapiaEstimulación neuromuscularParálisis facialPulsos bifásicoDesign and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsyDiseño y desarrollo de un equipo de estimulación eléctrica transcutánea para rehabilitación neuromuscular en personas con parálisis facialArtículo de revistahttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1Textinfo:eu-repo/semantics/articlehttp://purl.org/redcol/resource_type/ARTinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/version/c_970fb48d4fbd8a85PublicationORIGINALDesign and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy.pdfDesign and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy.pdfapplication/pdf468345https://repositorio.udes.edu.co/bitstreams/b12f1a08-1ec3-4a7c-a664-132a7e109d31/download5759dcb2a000131d1dfe0261a36cee9aMD58LICENSElicense.txtlicense.txttext/plain; charset=utf-859https://repositorio.udes.edu.co/bitstreams/7b0475e0-8d61-4f51-9952-2b6fa2d61132/download38d94cf55aa1bf2dac1a736ac45c881cMD53TEXTDiseño y desarrollo de un equipo de estimulación eléctrica transcutanea para rehabilitación neuromuscular en personas con parálisis facial.pdf.txtDiseño y desarrollo de un equipo de estimulación eléctrica transcutanea para rehabilitación neuromuscular en personas con parálisis facial.pdf.txtExtracted texttext/plain19093https://repositorio.udes.edu.co/bitstreams/de9df63c-a3aa-46a9-b2d6-dd07c9c9fbd8/downloada3f963df15dc594f382309fd3ed716a6MD54Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy.pdf.txtDesign and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy.pdf.txtExtracted texttext/plain22939https://repositorio.udes.edu.co/bitstreams/28e517db-1289-4202-8500-631db07e2d78/download1c64cc82b99ee295099fd004f1bb6026MD56THUMBNAILDiseño y desarrollo de un equipo de estimulación eléctrica transcutanea para rehabilitación neuromuscular en personas con parálisis facial.pdf.jpgDiseño y desarrollo de un equipo de estimulación eléctrica transcutanea para rehabilitación neuromuscular en personas con parálisis facial.pdf.jpgGenerated Thumbnailimage/jpeg2033https://repositorio.udes.edu.co/bitstreams/bf0fadbb-bc91-408d-b7f5-eccd17d77f31/download3fe9c51536286d5f577317bf9a1d8bc2MD55Design and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy.pdf.jpgDesign and development of transcutaneous electrical stimulation equipment for neuromuscular rehabilitation in individuals with facial palsy.pdf.jpgGenerated Thumbnailimage/jpeg1958https://repositorio.udes.edu.co/bitstreams/cdfa8213-9be9-473f-adb3-25954f9b8140/download10f2d332417d7c869e8deb82222cfbfdMD57001/3577oai:repositorio.udes.edu.co:001/35772023-10-11 13:22:24.347https://creativecommons.org/licenses/by-nc/4.0/Derechos Reservados - Universidad de Santander, 2014https://repositorio.udes.edu.coRepositorio Universidad de Santandersoporte@metabiblioteca.comTGljZW5jaWEgZGUgUHVibGljYWNpw7NuIFVERVMKRGlyZWN0cmljZXMgZGUgVVNPIHkgQUNDRVNPCgo= |