Reproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor
15 p.
- Autores:
-
Boneth Collantes, Milena del Carmen
Ariza García, Claudia Lucía
Angarita Fonseca, Adriana
Parra Patiño, Javier
Monsalve, Andrea
Gómez, Eliana
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2012
- Institución:
- Universidad de Santander
- Repositorio:
- Repositorio Universidad de Santander
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.udes.edu.co:001/3639
- Acceso en línea:
- https://repositorio.udes.edu.co/handle/001/3639
- Palabra clave:
- Physical fitness function
Reliability
Muscle endurance
Elderly
Aptitud física funcional
Reproducibilidad
Fuerza muscular
Adulto mayor
Aptidão física funcional
Reprodutibilidade
Resistência muscular
Idoso
- Rights
- openAccess
- License
- Derechos Reservados - Universidad de Santander, 2012
id |
RUDES2_68979b2e293958f7bf84c35f9c917352 |
---|---|
oai_identifier_str |
oai:repositorio.udes.edu.co:001/3639 |
network_acronym_str |
RUDES2 |
network_name_str |
Repositorio Universidad de Santander |
repository_id_str |
|
dc.title.spa.fl_str_mv |
Reproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor |
dc.title.alternative.eng.fl_str_mv |
Reliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people |
title |
Reproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor |
spellingShingle |
Reproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor Physical fitness function Reliability Muscle endurance Elderly Aptitud física funcional Reproducibilidad Fuerza muscular Adulto mayor Aptidão física funcional Reprodutibilidade Resistência muscular Idoso |
title_short |
Reproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor |
title_full |
Reproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor |
title_fullStr |
Reproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor |
title_full_unstemmed |
Reproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor |
title_sort |
Reproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor |
dc.creator.fl_str_mv |
Boneth Collantes, Milena del Carmen Ariza García, Claudia Lucía Angarita Fonseca, Adriana Parra Patiño, Javier Monsalve, Andrea Gómez, Eliana |
dc.contributor.author.spa.fl_str_mv |
Boneth Collantes, Milena del Carmen Ariza García, Claudia Lucía Angarita Fonseca, Adriana Parra Patiño, Javier Monsalve, Andrea Gómez, Eliana |
dc.subject.proposal.eng.fl_str_mv |
Physical fitness function Reliability Muscle endurance Elderly |
topic |
Physical fitness function Reliability Muscle endurance Elderly Aptitud física funcional Reproducibilidad Fuerza muscular Adulto mayor Aptidão física funcional Reprodutibilidade Resistência muscular Idoso |
dc.subject.proposal.spa.fl_str_mv |
Aptitud física funcional Reproducibilidad Fuerza muscular Adulto mayor |
dc.subject.proposal.por.fl_str_mv |
Aptidão física funcional Reprodutibilidade Resistência muscular Idoso |
description |
15 p. |
publishDate |
2012 |
dc.date.issued.spa.fl_str_mv |
2012-07-06 |
dc.date.accessioned.spa.fl_str_mv |
2019-08-24T14:57:10Z |
dc.date.available.spa.fl_str_mv |
2019-08-24T14:57:10Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.coarversion.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.issn.spa.fl_str_mv |
2145-4507 1692-7273 |
dc.identifier.uri.spa.fl_str_mv |
https://repositorio.udes.edu.co/handle/001/3639 |
identifier_str_mv |
2145-4507 1692-7273 |
url |
https://repositorio.udes.edu.co/handle/001/3639 |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.ispartof.spa.fl_str_mv |
Revista Ciencias de la Salud |
dc.relation.ispartofseries.spa.fl_str_mv |
Revista Ciencias de la Salud;Vol. 10 (2), pp. 15-29. 2012 |
dc.rights.spa.fl_str_mv |
Derechos Reservados - Universidad de Santander, 2012 |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.creativecommons.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0) |
dc.rights.uri.spa.fl_str_mv |
https://creativecommons.org/licenses/by-nc/4.0/ |
rights_invalid_str_mv |
Derechos Reservados - Universidad de Santander, 2012 Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0) https://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.source.eng.fl_str_mv |
http://www.scielo.org.co/pdf/recis/v10n2/v10n2a02.pdf |
institution |
Universidad de Santander |
bitstream.url.fl_str_mv |
https://repositorio.udes.edu.co/bitstreams/b27c5f64-4caa-4098-b92f-336b6326d736/download https://repositorio.udes.edu.co/bitstreams/c4430a77-8f0d-4a62-a03f-14e77626bdf8/download https://repositorio.udes.edu.co/bitstreams/fc3b18c4-6478-42fb-84bc-d6bf5bbc1511/download https://repositorio.udes.edu.co/bitstreams/30f197f8-f731-4b95-938e-7890f656ba4a/download https://repositorio.udes.edu.co/bitstreams/9e5dcbb6-ad5f-4dc9-8a2f-5487e5e6cd00/download https://repositorio.udes.edu.co/bitstreams/46cc5579-d0a0-407a-8c13-5b5bcabaab88/download |
bitstream.checksum.fl_str_mv |
5c8c6919ae30137e6b6c26411b0e0c57 5dbe86c1111d64f45ba435df98fdc825 7775bbc19cb10b3b30c01dffb1931524 9b6fa2801ca3aa5e06e979c30f58f248 8d51f8cc08885df02841152ebc43e354 38d94cf55aa1bf2dac1a736ac45c881c |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Universidad de Santander |
repository.mail.fl_str_mv |
soporte@metabiblioteca.com |
_version_ |
1814158797349847040 |
spelling |
Boneth Collantes, Milena del Carmen053c70df-e1b6-479d-a274-3c7c4803f618-1Ariza García, Claudia Lucíaa027adb2-cc9d-4b63-9ab9-006d65d24386-1Angarita Fonseca, Adrianacc09eddd-62ac-4be2-a577-9d029de10bfd-1Parra Patiño, Javier1a9f03a9-7447-40b1-9a73-5559e3f11d4e-1Monsalve, Andreacda23d15-c7e0-40a3-8ab8-11d57684c4e3-1Gómez, Eliana6043fe06-e85d-41e9-a09a-49c8eb509d7a-12019-08-24T14:57:10Z2019-08-24T14:57:10Z2012-07-0615 p.Objective: to assess the test-retest reliability and level of agreement between measures of the 30 second (30-s) Arm Curl and 30-s Chair Stand test in a sample of older adults from Bucaramanga.Materials and methods: a study of evaluation of diagnostic technology was done. Both tests were administered by the same evaluator to 111 adults older than 59 year-old (70,4 ± 7,3), on two occasions, with an interval of time between measures of 4 to 8 days. In the analysis, test-retest reliability was determined using the Intraclass Correlation Coefficient ICC= 2,1 with their confidence interval 95% (CI 95%) respective. The agreement level was established by the Bland and Altman method. Results: the test-retest reproducibility of the 30-s Arm Curl test was very good ICC= 0,88 and to the Chair Stand test was good ICC= 0,78. The agreement was very good for both tests of muscle endurance. The CI 95% were between -3,8 and 3,2 stands to 30-s Chair Stand test and between -3,1 and 2,8 curls to 30-s Arm Curl test. Conclusion: the 30-s Arm Curl and 30-s Chair Stand test have good reliability and agreement to assess muscle endurance in older adults functionally independent.Objetivo: evaluar la reproducibilidad prueba-reprueba y el nivel de acuerdo entre mediciones de las pruebas 30 seg (30-s) Arm Curl y 30-s Chair Stand en una muestra de adultos mayores de Bucaramanga. Materiales y métodos: se realizó un estudio de evaluación de tecnologías diagnósticas. Ambas pruebas fueron administradas en dos oportunidades por el mismo evaluador a 111 adultos mayores de 59 años (70,4 ± 7,3), con un intervalo de 4 a 8 días. En el análisis se determinó la reproducibilidad prueba-reprueba mediante el coeficiente de correlación intraclase, CCI= 2,1 con sus respectivos intervalos de confianza de 95% (IC 95%). El nivel de acuerdo se estableció mediante el método de Bland y Altman. Resultados: la reproducibilidad prueba-reprueba para el 30-s Arm Curl test fue muy buena, con un CCI= 0,88 y para el 30-s Chair Stand test fue buena, con un CCI= 0,78. Así, el acuerdo fue muy bueno para las dos pruebas de resistencia muscular. Los IC 95% estuvieron entre -3,8 y 3,2 repeticiones para la prueba 30-s Chair Stand y entre -3,1 y 2,8 repeticiones para la prueba 30-s Arm Curl. Conclusión: las pruebas 30-s Arm Curl y 30-s Chair Stand tienen buena reproducibilidad y nivel de acuerdo para evaluar resistencia muscular en adultos mayores funcionalmente independientes.Objetivo: avaliar a reprodutibilidade teste-reteste e nível de concordância entre as medidas de testes 30 second (30-s) Arm Curl e 30-s Chair Stand em uma amostra de idosos de Bucaramanga. Materiais e métodos: se realizou um estudo de avaliação da tecnologia de diagnóstico. Ambos os testes foram administrados pelo mesmo avaliador a 111 adultos com mais de 59 anos de idade (70,4 ± 7,3), em duas ocasiões, com um intervalo de tempo entre as medidas de 4 a 8 dias. Na análise, se determinou a reprodutibilidade teste-reteste usando o Coeficiente de Correlação Intraclasse ICC= 2,1 com seus respectivos intervalos de confiança de 95% (IC 95%). O nível de concordância foi estabelecido pelo método de Bland e Altman. Resultados: a reprodutibilidade teste-reteste do 30-s Arm Curl teste era muito bom ICC= 0,88 e do 30-s Chair Stand teste foi boa ICC= 0,78. O acordo foi muito bom para ambos os testes de resistência muscular. Os IC 95% foram de -3,8 e 3,2 repetições para o 30-s Chair Stand teste e de -3,1 e 2,8 repetições para o 30-s Arm Curl teste. Conclusão: testes 30-s Arm Curl e 30-s Chair Stand possui boa reprodutibilidade e concordância para avaliar a resistência muscular em idosos funcionalmente independentes.application/pdf2145-45071692-7273https://repositorio.udes.edu.co/handle/001/3639spaRevista Ciencias de la SaludRevista Ciencias de la Salud;Vol. 10 (2), pp. 15-29. 2012Derechos Reservados - Universidad de Santander, 2012info:eu-repo/semantics/openAccessAtribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)https://creativecommons.org/licenses/by-nc/4.0/http://purl.org/coar/access_right/c_abf2http://www.scielo.org.co/pdf/recis/v10n2/v10n2a02.pdfPhysical fitness functionReliabilityMuscle enduranceElderlyAptitud física funcionalReproducibilidadFuerza muscularAdulto mayorAptidão física funcionalReprodutibilidadeResistência muscularIdosoReproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayorReliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older peopleArtículo de revistahttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1Textinfo:eu-repo/semantics/articlehttp://purl.org/redcol/resource_type/ARTinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/version/c_970fb48d4fbd8a85PublicationTEXTReliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people.pdf.txtReliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people.pdf.txtExtracted texttext/plain45986https://repositorio.udes.edu.co/bitstreams/b27c5f64-4caa-4098-b92f-336b6326d736/download5c8c6919ae30137e6b6c26411b0e0c57MD53Reproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor.pdf.txtReproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor.pdf.txtExtracted texttext/plain5https://repositorio.udes.edu.co/bitstreams/c4430a77-8f0d-4a62-a03f-14e77626bdf8/download5dbe86c1111d64f45ba435df98fdc825MD56THUMBNAILReliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people.pdf.jpgReliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people.pdf.jpgGenerated Thumbnailimage/jpeg1612https://repositorio.udes.edu.co/bitstreams/fc3b18c4-6478-42fb-84bc-d6bf5bbc1511/download7775bbc19cb10b3b30c01dffb1931524MD54Reproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor.pdf.jpgReproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor.pdf.jpgGenerated Thumbnailimage/jpeg10088https://repositorio.udes.edu.co/bitstreams/30f197f8-f731-4b95-938e-7890f656ba4a/download9b6fa2801ca3aa5e06e979c30f58f248MD57ORIGINALReproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor.pdfReproducibilidad de las pruebas Arm Curl y Chair Stand para evaluar resistencia muscular en población adulta mayor.pdfapplication/pdf257036https://repositorio.udes.edu.co/bitstreams/9e5dcbb6-ad5f-4dc9-8a2f-5487e5e6cd00/download8d51f8cc08885df02841152ebc43e354MD55LICENSElicense.txtlicense.txttext/plain; charset=utf-859https://repositorio.udes.edu.co/bitstreams/46cc5579-d0a0-407a-8c13-5b5bcabaab88/download38d94cf55aa1bf2dac1a736ac45c881cMD52001/3639oai:repositorio.udes.edu.co:001/36392023-10-10 09:55:24.826https://creativecommons.org/licenses/by-nc/4.0/Derechos Reservados - Universidad de Santander, 2012https://repositorio.udes.edu.coRepositorio Universidad de Santandersoporte@metabiblioteca.comTGljZW5jaWEgZGUgUHVibGljYWNpw7NuIFVERVMKRGlyZWN0cmljZXMgZGUgVVNPIHkgQUNDRVNPCgo= |