Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study

9 páginas

Autores:
Giraldo Cadavid, Luis Fernando
Bastidas Goyes, Alirio Rodrigo
Padilla-Ortiz, Diana Marcela
Concha Galan, Diana Carolina
Bazurto Zapata, María Angélica
Vargas, Leslie
Tipo de recurso:
Fecha de publicación:
2017
Institución:
Universidad de la Sabana
Repositorio:
Repositorio Universidad de la Sabana
Idioma:
eng
OAI Identifier:
oai:intellectum.unisabana.edu.co:10818/32834
Acceso en línea:
http://bmjopen.bmj.com/content/7/8/e015235.long
http://hdl.handle.net/10818/32834
Palabra clave:
Rights
License
Attribution-NonCommercial-NoDerivatives 4.0 International
id REPOUSABA2_e71b6c4b40d281a322b43237dc60669c
oai_identifier_str oai:intellectum.unisabana.edu.co:10818/32834
network_acronym_str REPOUSABA2
network_name_str Repositorio Universidad de la Sabana
repository_id_str
spelling Giraldo Cadavid, Luis FernandoBastidas Goyes, Alirio RodrigoPadilla-Ortiz, Diana MarcelaConcha Galan, Diana CarolinaBazurto Zapata, María AngélicaVargas, Leslie4/24/2018 11:382018-04-24T16:38:21Z2017Giraldo-Cadavid LF, Bastidas AR, Padilla-Ortiz DM, et al Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study BMJ Open 2017;7:e015235. doi: 10.1136/bmjopen-2016-015235http://bmjopen.bmj.com/content/7/8/e015235.longhttp://hdl.handle.net/10818/3283410.1136/bmjopen-2016-0152359 páginasPatients with obstructive sleep apnoea hypopnoea syndrome (OSA) might have varying degrees of laryngopharyngeal mechanical hyposensitivity that might impair the brain’s capacity to prevent airway collapse during sleep. However, this knowledge about sensory compromises in OSA comes from studies performed using methods with little evidence of their validity. Hence, the purpose of this study is to assess the reliability and accuracy of the measurement of laryngopharyngeal mechanosensitivity in patients with OSA using a recently developed laryngopharyngeal endoscopic esthesiometer and rangefinder (LPEER).application/pdfengBMJ : British Medical JournalBMJ Open 2017; 7: e015235Attribution-NonCommercial-NoDerivatives 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-nd/4.0/http://purl.org/coar/access_right/c_abf2Universidad de La SabanaIntellectum Repositorio Universidad de La SabanaAccuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory studyExactitud y fiabilidad de la prueba sensorial realizada con el estetoscopio endoscópico laringofaríngeo y el telémetro en pacientes con sospecha de apnea obstructiva del sueño hipopnea: protocolo para un estudio prospectivo, doble ciego, aleatorizado, exploratorioarticlepublishedVersionhttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_6501ORIGINALAccuracy and reliability.pdfAccuracy and reliability.pdfVer artículoapplication/pdf517402https://intellectum.unisabana.edu.co/bitstream/10818/32834/1/Accuracy%20and%20reliability.pdf00ba96cb2f775d8ac84b6141cd19847eMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-8498https://intellectum.unisabana.edu.co/bitstream/10818/32834/3/license.txtf52a2cfd4df262e08e9b300d62c85cabMD53TEXTAccuracy and reliability.pdf.txtAccuracy and reliability.pdf.txtExtracted Texttext/plain50269https://intellectum.unisabana.edu.co/bitstream/10818/32834/4/Accuracy%20and%20reliability.pdf.txt4f9852b849963142f0a1e7573414b0c0MD54CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-81223https://intellectum.unisabana.edu.co/bitstream/10818/32834/2/license_rdf7c9ab7f006165862d8ce9ac5eac01552MD5210818/32834oai:intellectum.unisabana.edu.co:10818/328342022-05-10 05:17:29.78Intellectum Universidad de la Sabanacontactointellectum@unisabana.edu.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
dc.title.es_CO.fl_str_mv Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study
dc.title.alternative.es_CO.fl_str_mv Exactitud y fiabilidad de la prueba sensorial realizada con el estetoscopio endoscópico laringofaríngeo y el telémetro en pacientes con sospecha de apnea obstructiva del sueño hipopnea: protocolo para un estudio prospectivo, doble ciego, aleatorizado, exploratorio
title Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study
spellingShingle Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study
title_short Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study
title_full Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study
title_fullStr Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study
title_full_unstemmed Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study
title_sort Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study
dc.creator.fl_str_mv Giraldo Cadavid, Luis Fernando
Bastidas Goyes, Alirio Rodrigo
Padilla-Ortiz, Diana Marcela
Concha Galan, Diana Carolina
Bazurto Zapata, María Angélica
Vargas, Leslie
dc.contributor.author.none.fl_str_mv Giraldo Cadavid, Luis Fernando
Bastidas Goyes, Alirio Rodrigo
Padilla-Ortiz, Diana Marcela
Concha Galan, Diana Carolina
Bazurto Zapata, María Angélica
Vargas, Leslie
description 9 páginas
publishDate 2017
dc.date.issued.none.fl_str_mv 2017
dc.date.available.none.fl_str_mv 2018-04-24T16:38:21Z
dc.date.accessioned.none.fl_str_mv 4/24/2018 11:38
dc.type.en.fl_str_mv article
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.hasVersion.es_CO.fl_str_mv publishedVersion
dc.identifier.citation.es_CO.fl_str_mv Giraldo-Cadavid LF, Bastidas AR, Padilla-Ortiz DM, et al Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study BMJ Open 2017;7:e015235. doi: 10.1136/bmjopen-2016-015235
dc.identifier.other.none.fl_str_mv http://bmjopen.bmj.com/content/7/8/e015235.long
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/10818/32834
dc.identifier.doi.none.fl_str_mv 10.1136/bmjopen-2016-015235
identifier_str_mv Giraldo-Cadavid LF, Bastidas AR, Padilla-Ortiz DM, et al Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study BMJ Open 2017;7:e015235. doi: 10.1136/bmjopen-2016-015235
10.1136/bmjopen-2016-015235
url http://bmjopen.bmj.com/content/7/8/e015235.long
http://hdl.handle.net/10818/32834
dc.language.iso.es_CO.fl_str_mv eng
language eng
dc.relation.ispartofseries.none.fl_str_mv BMJ Open 2017; 7: e015235
dc.rights.*.fl_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.uri.*.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
rights_invalid_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
http://purl.org/coar/access_right/c_abf2
dc.format.es_CO.fl_str_mv application/pdf
dc.publisher.es_CO.fl_str_mv BMJ : British Medical Journal
dc.source.es_CO.fl_str_mv Universidad de La Sabana
Intellectum Repositorio Universidad de La Sabana
institution Universidad de la Sabana
bitstream.url.fl_str_mv https://intellectum.unisabana.edu.co/bitstream/10818/32834/1/Accuracy%20and%20reliability.pdf
https://intellectum.unisabana.edu.co/bitstream/10818/32834/3/license.txt
https://intellectum.unisabana.edu.co/bitstream/10818/32834/4/Accuracy%20and%20reliability.pdf.txt
https://intellectum.unisabana.edu.co/bitstream/10818/32834/2/license_rdf
bitstream.checksum.fl_str_mv 00ba96cb2f775d8ac84b6141cd19847e
f52a2cfd4df262e08e9b300d62c85cab
4f9852b849963142f0a1e7573414b0c0
7c9ab7f006165862d8ce9ac5eac01552
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Intellectum Universidad de la Sabana
repository.mail.fl_str_mv contactointellectum@unisabana.edu.co
_version_ 1811952264910209024