Effect of the Harmonic Voltage Distortion on the Efficiency of a Compact Fluorescent Lamp

This paper evaluates the effect of the voltage harmonic distortion over the efficiency of a compact fluorescent lamp that is fed with a constant RMS voltage and constant frequency. Several works have been published about the assessment of compact fluorescent lamps, but the effect of the voltage dist...

Full description

Autores:
Tipo de recurso:
Fecha de publicación:
2020
Institución:
Universidad Pedagógica y Tecnológica de Colombia
Repositorio:
RiUPTC: Repositorio Institucional UPTC
Idioma:
eng
OAI Identifier:
oai:repositorio.uptc.edu.co:001/14280
Acceso en línea:
https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11604
https://repositorio.uptc.edu.co/handle/001/14280
Palabra clave:
compact fluorescent lamp
efficiency reduction
electrical machine laboratory
harmonic source
voltage harmonic distortion
distorsión armónica de voltaje
fuente armónica
laboratorio de máquinas eléctricas
lámpara fluorescente compacta
reducción de eficiencia
Rights
License
http://purl.org/coar/access_right/c_abf304
id REPOUPTC2_fab597c191512e8722aedf9808f49287
oai_identifier_str oai:repositorio.uptc.edu.co:001/14280
network_acronym_str REPOUPTC2
network_name_str RiUPTC: Repositorio Institucional UPTC
repository_id_str
dc.title.en-US.fl_str_mv Effect of the Harmonic Voltage Distortion on the Efficiency of a Compact Fluorescent Lamp
dc.title.es-ES.fl_str_mv Efecto de la distorsión armónica de voltaje en la eficiencia de una lámpara compacta fluorescente
title Effect of the Harmonic Voltage Distortion on the Efficiency of a Compact Fluorescent Lamp
spellingShingle Effect of the Harmonic Voltage Distortion on the Efficiency of a Compact Fluorescent Lamp
compact fluorescent lamp
efficiency reduction
electrical machine laboratory
harmonic source
voltage harmonic distortion
distorsión armónica de voltaje
fuente armónica
laboratorio de máquinas eléctricas
lámpara fluorescente compacta
reducción de eficiencia
title_short Effect of the Harmonic Voltage Distortion on the Efficiency of a Compact Fluorescent Lamp
title_full Effect of the Harmonic Voltage Distortion on the Efficiency of a Compact Fluorescent Lamp
title_fullStr Effect of the Harmonic Voltage Distortion on the Efficiency of a Compact Fluorescent Lamp
title_full_unstemmed Effect of the Harmonic Voltage Distortion on the Efficiency of a Compact Fluorescent Lamp
title_sort Effect of the Harmonic Voltage Distortion on the Efficiency of a Compact Fluorescent Lamp
dc.subject.en-US.fl_str_mv compact fluorescent lamp
efficiency reduction
electrical machine laboratory
harmonic source
voltage harmonic distortion
topic compact fluorescent lamp
efficiency reduction
electrical machine laboratory
harmonic source
voltage harmonic distortion
distorsión armónica de voltaje
fuente armónica
laboratorio de máquinas eléctricas
lámpara fluorescente compacta
reducción de eficiencia
dc.subject.es-ES.fl_str_mv distorsión armónica de voltaje
fuente armónica
laboratorio de máquinas eléctricas
lámpara fluorescente compacta
reducción de eficiencia
description This paper evaluates the effect of the voltage harmonic distortion over the efficiency of a compact fluorescent lamp that is fed with a constant RMS voltage and constant frequency. Several works have been published about the assessment of compact fluorescent lamps, but the effect of the voltage distortion over the efficiency is still an open topic. This work focuses on designing an experiment to estimate the efficiency of a compact fluorescent lamp while changing the voltage harmonic distortion of the power supply. First, a mathematical model that represents a bus susceptible to harmonic distortion (high impedance) that feeds the compact fluorescent lamp is analyzed. Then the mathematical model is reproduced through a test bench in a laboratory of rotating electrical machines. The test bench produces a three-phase bus with constant voltage and frequency, and variable voltage harmonic distortion. The compact fluorescent lamp is subjected to varying harmonic voltage distortion while recording its electrical variables and the produced lumens to estimate its efficiency. That is a practical approach to calculate the lamp efficiency while several works limit their scope measuring only the efficiency of the input converter. The experimental results show that a variation of the voltage harmonic distortion of 8 % on a compact fluorescent lamp reduces its efficiency. Those results put into evidence the importance of regulating harmonic distortion limits to reduce or prevent the increment of power losses caused by harmonic components.
publishDate 2020
dc.date.accessioned.none.fl_str_mv 2024-07-05T19:11:54Z
dc.date.available.none.fl_str_mv 2024-07-05T19:11:54Z
dc.date.none.fl_str_mv 2020-10-31
dc.type.none.fl_str_mv info:eu-repo/semantics/article
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a387
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11604
10.19053/01211129.v29.n54.2020.11604
dc.identifier.uri.none.fl_str_mv https://repositorio.uptc.edu.co/handle/001/14280
url https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11604
https://repositorio.uptc.edu.co/handle/001/14280
identifier_str_mv 10.19053/01211129.v29.n54.2020.11604
dc.language.none.fl_str_mv eng
dc.language.iso.spa.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11604/9817
https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11604/10020
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf304
rights_invalid_str_mv http://purl.org/coar/access_right/c_abf304
http://purl.org/coar/access_right/c_abf2
dc.format.none.fl_str_mv application/pdf
application/xml
dc.publisher.en-US.fl_str_mv Universidad Pedagógica y Tecnológica de Colombia
dc.source.en-US.fl_str_mv Revista Facultad de Ingeniería; Vol. 29 No. 54 (2020): Continuos Publication; e11604
dc.source.es-ES.fl_str_mv Revista Facultad de Ingeniería; Vol. 29 Núm. 54 (2020): Publicación Continua; e11604
dc.source.none.fl_str_mv 2357-5328
0121-1129
institution Universidad Pedagógica y Tecnológica de Colombia
repository.name.fl_str_mv Repositorio Institucional UPTC
repository.mail.fl_str_mv repositorio.uptc@uptc.edu.co
_version_ 1839633869560610816
spelling 2020-10-312024-07-05T19:11:54Z2024-07-05T19:11:54Zhttps://revistas.uptc.edu.co/index.php/ingenieria/article/view/1160410.19053/01211129.v29.n54.2020.11604https://repositorio.uptc.edu.co/handle/001/14280This paper evaluates the effect of the voltage harmonic distortion over the efficiency of a compact fluorescent lamp that is fed with a constant RMS voltage and constant frequency. Several works have been published about the assessment of compact fluorescent lamps, but the effect of the voltage distortion over the efficiency is still an open topic. This work focuses on designing an experiment to estimate the efficiency of a compact fluorescent lamp while changing the voltage harmonic distortion of the power supply. First, a mathematical model that represents a bus susceptible to harmonic distortion (high impedance) that feeds the compact fluorescent lamp is analyzed. Then the mathematical model is reproduced through a test bench in a laboratory of rotating electrical machines. The test bench produces a three-phase bus with constant voltage and frequency, and variable voltage harmonic distortion. The compact fluorescent lamp is subjected to varying harmonic voltage distortion while recording its electrical variables and the produced lumens to estimate its efficiency. That is a practical approach to calculate the lamp efficiency while several works limit their scope measuring only the efficiency of the input converter. The experimental results show that a variation of the voltage harmonic distortion of 8 % on a compact fluorescent lamp reduces its efficiency. Those results put into evidence the importance of regulating harmonic distortion limits to reduce or prevent the increment of power losses caused by harmonic components.En este artículo se evalúa el efecto de la distorsión armónica de voltaje sobre la eficiencia de una lámpara fluorescente compacta que es alimentada con un voltaje RMS y una frecuencia constante. Varios trabajos se han publicado acerca de la evaluación de lámparas fluorescentes compactas, pero el efecto de la distorsión de voltaje sobre la eficiencia aún es un tópico abierto. Este trabajo se enfoca en diseñar un experimento para estimar la eficiencia de una lámpara compacta fluorescente mientras cambia la distorsión armónica de voltaje de la fuente de alimentación. Se parte de un modelo matemático que representa un barraje susceptible a la distorsión armónica (alta impedancia) que alimenta la lámpara compacta fluorescente. Luego, el modelo matemático es reproducido a través de un banco de pruebas en un laboratorio de máquinas eléctricas rotativas. El banco de pruebas produce un barraje trifásico con voltaje y frecuencia constantes, y una distorsión armónica de voltaje variable. La lámpara fluorescente compacta es sometida a la variación de la distorsión armónica de voltaje mientras se registran sus variables eléctricas y los lúmenes producidos para estimar su eficiencia. Esta es una aproximación práctica para calcular la eficiencia de la lámpara, mientras que varios trabajos limitan su alcance midiendo solamente la eficiencia del convertidor de entrada. Los resultados experimentales muestran que una variación de la distorsión armónica de voltaje del 8 % en una lámpara fluorescente compacta reduce su eficiencia. Estos resultados ponen en evidencia la importancia de reducir los límites de distorsión armónica para reducir o prevenir el incremento de pérdidas de potencia causadas por componentes armónicos.application/pdfapplication/xmlengengUniversidad Pedagógica y Tecnológica de Colombiahttps://revistas.uptc.edu.co/index.php/ingenieria/article/view/11604/9817https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11604/10020Copyright (c) 2020 Esteban Rojas-Osorio, Andrés Julián Saavedra-Montes, Ph. D., Carlos Andrés Ramos-Paja, Ph. D.http://purl.org/coar/access_right/c_abf304http://purl.org/coar/access_right/c_abf2Revista Facultad de Ingeniería; Vol. 29 No. 54 (2020): Continuos Publication; e11604Revista Facultad de Ingeniería; Vol. 29 Núm. 54 (2020): Publicación Continua; e116042357-53280121-1129compact fluorescent lampefficiency reductionelectrical machine laboratoryharmonic sourcevoltage harmonic distortiondistorsión armónica de voltajefuente armónicalaboratorio de máquinas eléctricaslámpara fluorescente compactareducción de eficienciaEffect of the Harmonic Voltage Distortion on the Efficiency of a Compact Fluorescent LampEfecto de la distorsión armónica de voltaje en la eficiencia de una lámpara compacta fluorescenteinfo:eu-repo/semantics/articlehttp://purl.org/coar/resource_type/c_2df8fbb1info:eu-repo/semantics/publishedVersionhttp://purl.org/coar/version/c_970fb48d4fbd8a387http://purl.org/coar/version/c_970fb48d4fbd8a85Rojas-Osorio, EstebanSaavedra-Montes, Andrés JuliánRamos-Paja, Carlos Andrés001/14280oai:repositorio.uptc.edu.co:001/142802025-07-18 11:53:51.117metadata.onlyhttps://repositorio.uptc.edu.coRepositorio Institucional UPTCrepositorio.uptc@uptc.edu.co