Evaluation of Parameters in the Removal of Linear Alkylbenzene Sulfonate Anionic Surfactant Using Electrocoagulation
The objective of the present investigation was to construct an electrocoagulation cell in a batch system and to evaluate its capacity to remove the anionic surfactant of the linear alkylbenzene sulfonate (LAS), which is present in gray water determining the effect of the type of electrodes (Al or Fe...
- Autores:
- Tipo de recurso:
- Fecha de publicación:
- 2020
- Institución:
- Universidad Pedagógica y Tecnológica de Colombia
- Repositorio:
- RiUPTC: Repositorio Institucional UPTC
- Idioma:
- eng
spa
- OAI Identifier:
- oai:repositorio.uptc.edu.co:001/14279
- Acceso en línea:
- https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11570
https://repositorio.uptc.edu.co/handle/001/14279
- Palabra clave:
- Emerging contaminants
shortwave electrolysis
electrochemistry
LAS
contaminantes emergentes
electrólisis de onda corta
electroquímica
LAS
- Rights
- License
- http://creativecommons.org/licenses/by/4.0
id |
REPOUPTC2_5a822f5d70078c64f1c6c23b7f3e6d63 |
---|---|
oai_identifier_str |
oai:repositorio.uptc.edu.co:001/14279 |
network_acronym_str |
REPOUPTC2 |
network_name_str |
RiUPTC: Repositorio Institucional UPTC |
repository_id_str |
|
dc.title.en-US.fl_str_mv |
Evaluation of Parameters in the Removal of Linear Alkylbenzene Sulfonate Anionic Surfactant Using Electrocoagulation |
dc.title.es-ES.fl_str_mv |
Evaluación de parámetros en la remoción de surfactante aniónico tipo Alquilbenceno sulfonato lineal usando electrocoagulación |
title |
Evaluation of Parameters in the Removal of Linear Alkylbenzene Sulfonate Anionic Surfactant Using Electrocoagulation |
spellingShingle |
Evaluation of Parameters in the Removal of Linear Alkylbenzene Sulfonate Anionic Surfactant Using Electrocoagulation Emerging contaminants shortwave electrolysis electrochemistry LAS contaminantes emergentes electrólisis de onda corta electroquímica LAS |
title_short |
Evaluation of Parameters in the Removal of Linear Alkylbenzene Sulfonate Anionic Surfactant Using Electrocoagulation |
title_full |
Evaluation of Parameters in the Removal of Linear Alkylbenzene Sulfonate Anionic Surfactant Using Electrocoagulation |
title_fullStr |
Evaluation of Parameters in the Removal of Linear Alkylbenzene Sulfonate Anionic Surfactant Using Electrocoagulation |
title_full_unstemmed |
Evaluation of Parameters in the Removal of Linear Alkylbenzene Sulfonate Anionic Surfactant Using Electrocoagulation |
title_sort |
Evaluation of Parameters in the Removal of Linear Alkylbenzene Sulfonate Anionic Surfactant Using Electrocoagulation |
dc.subject.en-US.fl_str_mv |
Emerging contaminants shortwave electrolysis electrochemistry LAS |
topic |
Emerging contaminants shortwave electrolysis electrochemistry LAS contaminantes emergentes electrólisis de onda corta electroquímica LAS |
dc.subject.es-ES.fl_str_mv |
contaminantes emergentes electrólisis de onda corta electroquímica LAS |
description |
The objective of the present investigation was to construct an electrocoagulation cell in a batch system and to evaluate its capacity to remove the anionic surfactant of the linear alkylbenzene sulfonate (LAS), which is present in gray water determining the effect of the type of electrodes (Al or Fe), distance between electrodes (1, 1.5 and 2 cm) and voltages (10, 15 and 20 V). The experimental tests were carried out for 20 min. The dimensions of the short wave electrolysis cell built in glass were 26 cm long, 7 cm wide and 12 cm high, with 10 electrodes of 12x6 cm supported by a PVC structure. The concentration of LAS in the solution was determined by employing UV-Vis spectrometry applying the Methylene Blue Active Substances (MBAS) method. A higher removal of 65.55% was obtained when aluminum electrodes were used, and 69.11% with iron electrodes a separation of 1.5 cm and a voltage of 20 V, presenting less change in pH, conductivity, and energy consumption when using the Al3 electrode. When evaluating the effect of time at the best experimental configuration (Al, 1.5 cm, 20 V) it was established that the removal efficiency increased to 75.13% in 60 min. Electrocoagulation with aluminum electrodes is presented as an efficient alternative for the removal of LAS in solution. |
publishDate |
2020 |
dc.date.accessioned.none.fl_str_mv |
2024-07-05T19:11:54Z |
dc.date.available.none.fl_str_mv |
2024-07-05T19:11:54Z |
dc.date.none.fl_str_mv |
2020-12-29 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.coarversion.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coarversion.spa.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a417 |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11570 10.19053/01211129.v30.n55.2021.11570 |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.uptc.edu.co/handle/001/14279 |
url |
https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11570 https://repositorio.uptc.edu.co/handle/001/14279 |
identifier_str_mv |
10.19053/01211129.v30.n55.2021.11570 |
dc.language.none.fl_str_mv |
eng spa |
dc.language.iso.spa.fl_str_mv |
eng spa |
language |
eng spa |
dc.relation.none.fl_str_mv |
https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11570/10034 https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11570/10035 https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11570/10781 |
dc.rights.en-US.fl_str_mv |
http://creativecommons.org/licenses/by/4.0 |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.coar.spa.fl_str_mv |
http://purl.org/coar/access_right/c_abf334 |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by/4.0 http://purl.org/coar/access_right/c_abf334 http://purl.org/coar/access_right/c_abf2 |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/xml |
dc.publisher.en-US.fl_str_mv |
Universidad Pedagógica y Tecnológica de Colombia |
dc.source.en-US.fl_str_mv |
Revista Facultad de Ingeniería; Vol. 30 No. 55 (2021): January-March 2021 (Continuous Publication); e11570 |
dc.source.es-ES.fl_str_mv |
Revista Facultad de Ingeniería; Vol. 30 Núm. 55 (2021): Enero-Marzo 2021 (Publicación Continua); e11570 |
dc.source.none.fl_str_mv |
2357-5328 0121-1129 |
institution |
Universidad Pedagógica y Tecnológica de Colombia |
repository.name.fl_str_mv |
Repositorio Institucional UPTC |
repository.mail.fl_str_mv |
repositorio.uptc@uptc.edu.co |
_version_ |
1839633875859406848 |
spelling |
2020-12-292024-07-05T19:11:54Z2024-07-05T19:11:54Zhttps://revistas.uptc.edu.co/index.php/ingenieria/article/view/1157010.19053/01211129.v30.n55.2021.11570https://repositorio.uptc.edu.co/handle/001/14279The objective of the present investigation was to construct an electrocoagulation cell in a batch system and to evaluate its capacity to remove the anionic surfactant of the linear alkylbenzene sulfonate (LAS), which is present in gray water determining the effect of the type of electrodes (Al or Fe), distance between electrodes (1, 1.5 and 2 cm) and voltages (10, 15 and 20 V). The experimental tests were carried out for 20 min. The dimensions of the short wave electrolysis cell built in glass were 26 cm long, 7 cm wide and 12 cm high, with 10 electrodes of 12x6 cm supported by a PVC structure. The concentration of LAS in the solution was determined by employing UV-Vis spectrometry applying the Methylene Blue Active Substances (MBAS) method. A higher removal of 65.55% was obtained when aluminum electrodes were used, and 69.11% with iron electrodes a separation of 1.5 cm and a voltage of 20 V, presenting less change in pH, conductivity, and energy consumption when using the Al3 electrode. When evaluating the effect of time at the best experimental configuration (Al, 1.5 cm, 20 V) it was established that the removal efficiency increased to 75.13% in 60 min. Electrocoagulation with aluminum electrodes is presented as an efficient alternative for the removal of LAS in solution.El objetivo de la presente investigación fue construir una celda de electrocoagulación en sistema por lotes y evaluar su capacidad de remover el surfactante aniónico de tipo Alquilbenceno sulfonato lineal (LAS) presente en aguas grises determinando el efecto del tipo de electrodos (Al o Fe), distancia entre electrodos (1, 1.5 y 2 cm) y voltajes de (10, 15 y 20 V). Los ensayos experimentales se realizaron durante 20 min. Las dimensiones de la celda electrólisis de onda corta construida en vidrio fueron 26 cm de largo, 7 cm de ancho y 12 cm de alto, con 10 electrodos de 12x6 cm sostenidos por una estructura de PVC. Se determinó la concentración de LAS en la solución mediante espectometria UV-Vis aplicando el método el método de Sustancias Activas al Azul de Metileno (SAAM). Se obtuvo una mayor remoción del 65.55% cuando se usó electrodos de aluminio, y 69.11% con electrodos de hierro una separación de 1.5 cm y un voltaje de 20 V, presentándose menor cambio en el pH, conductividad y consumo energético al usar el electrodo de Al3. Al evaluar el efecto del tiempo a la mejor configuración experimental (Al, 1.5 cm, 20 V) se estableció que la eficiencia de remoción aumentó a 75.13% en 60 min. Se presenta la electrocoagulación con electrodos de aluminios como una alternativa eficiente para la remoción de LAS en solución.application/pdfapplication/pdfapplication/xmlengspaengspaUniversidad Pedagógica y Tecnológica de Colombiahttps://revistas.uptc.edu.co/index.php/ingenieria/article/view/11570/10034https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11570/10035https://revistas.uptc.edu.co/index.php/ingenieria/article/view/11570/10781Copyright (c) 2021 Angel Villabona-Ortíz, M.Sc., Candelaria Tejada-Tovar, M.Sc., Lenis De-La-Rosa-Jiménezhttp://creativecommons.org/licenses/by/4.0http://purl.org/coar/access_right/c_abf334http://purl.org/coar/access_right/c_abf2Revista Facultad de Ingeniería; Vol. 30 No. 55 (2021): January-March 2021 (Continuous Publication); e11570Revista Facultad de Ingeniería; Vol. 30 Núm. 55 (2021): Enero-Marzo 2021 (Publicación Continua); e115702357-53280121-1129Emerging contaminantsshortwave electrolysiselectrochemistryLAScontaminantes emergenteselectrólisis de onda cortaelectroquímicaLASEvaluation of Parameters in the Removal of Linear Alkylbenzene Sulfonate Anionic Surfactant Using ElectrocoagulationEvaluación de parámetros en la remoción de surfactante aniónico tipo Alquilbenceno sulfonato lineal usando electrocoagulacióninfo:eu-repo/semantics/articlehttp://purl.org/coar/resource_type/c_2df8fbb1info:eu-repo/semantics/publishedVersionhttp://purl.org/coar/version/c_970fb48d4fbd8a417http://purl.org/coar/version/c_970fb48d4fbd8a85Villabona-Ortíz, AngelTejada-Tovar, CandelariaDe-La-Rosa-Jiménez, Lenis001/14279oai:repositorio.uptc.edu.co:001/142792025-07-18 11:53:51.227metadata.onlyhttps://repositorio.uptc.edu.coRepositorio Institucional UPTCrepositorio.uptc@uptc.edu.co |