Diseño e implementación de un sistema de gestión de información para la determinación de la calidad del aire en el campus de la Universidad del Norte
The Universidad del Norte has a pollution monitor located in an area that is difficult to access for the university community, making it difficult to obtain the data measured by it. A real-time acquisition system was designed where the data measured by the monitor are sent to a web server, where the...
- Autores:
-
Linero Vassallo, Daniel Alfredo
- Tipo de recurso:
- Fecha de publicación:
- 2023
- Institución:
- Universidad del Norte
- Repositorio:
- Repositorio Uninorte
- Idioma:
- spa
- OAI Identifier:
- oai:manglar.uninorte.edu.co:10584/11547
- Acceso en línea:
- http://hdl.handle.net/10584/11547
- Palabra clave:
- Visualización
Plataforma
Polución
Polution
Visualization
Platform
- Rights
- License
- Universidad del Norte
id |
REPOUNORT2_6d8f5758747fd6e7476f66bdcc6da094 |
---|---|
oai_identifier_str |
oai:manglar.uninorte.edu.co:10584/11547 |
network_acronym_str |
REPOUNORT2 |
network_name_str |
Repositorio Uninorte |
repository_id_str |
|
dc.title.es_ES.fl_str_mv |
Diseño e implementación de un sistema de gestión de información para la determinación de la calidad del aire en el campus de la Universidad del Norte Design and implementation of an information management system for the determination of air quality on the Universidad del Norte campus |
title |
Diseño e implementación de un sistema de gestión de información para la determinación de la calidad del aire en el campus de la Universidad del Norte |
spellingShingle |
Diseño e implementación de un sistema de gestión de información para la determinación de la calidad del aire en el campus de la Universidad del Norte Visualización Plataforma Polución Polution Visualization Platform |
title_short |
Diseño e implementación de un sistema de gestión de información para la determinación de la calidad del aire en el campus de la Universidad del Norte |
title_full |
Diseño e implementación de un sistema de gestión de información para la determinación de la calidad del aire en el campus de la Universidad del Norte |
title_fullStr |
Diseño e implementación de un sistema de gestión de información para la determinación de la calidad del aire en el campus de la Universidad del Norte |
title_full_unstemmed |
Diseño e implementación de un sistema de gestión de información para la determinación de la calidad del aire en el campus de la Universidad del Norte |
title_sort |
Diseño e implementación de un sistema de gestión de información para la determinación de la calidad del aire en el campus de la Universidad del Norte |
dc.creator.fl_str_mv |
Linero Vassallo, Daniel Alfredo |
dc.contributor.advisor.none.fl_str_mv |
Gómez, Diego Clavijo, Carlos |
dc.contributor.author.none.fl_str_mv |
Linero Vassallo, Daniel Alfredo |
dc.subject.es_ES.fl_str_mv |
Visualización Plataforma Polución |
topic |
Visualización Plataforma Polución Polution Visualization Platform |
dc.subject.en_US.fl_str_mv |
Polution Visualization Platform |
description |
The Universidad del Norte has a pollution monitor located in an area that is difficult to access for the university community, making it difficult to obtain the data measured by it. A real-time acquisition system was designed where the data measured by the monitor are sent to a web server, where they are stored and displayed on a web page where graphs of these data are shown in addition to graphs and tables where historical values of energy consumption within the university are correlated. The system was designed using a Raspberry pi 4B microcontroller connected by serial communication to the monitor, the microcontroller was connected to an external GSM module to send the data received to the web server and displayed on a web page programmed with Javascript, PHP, HTML, and CSS. After the development, it was concluded that the system worked correctly sending and receiving data on the web page where you can view historical values, real-time data, and showing correlation graphs, redundancy was implemented in the system of receiving and displaying data to strengthen the designed system. |
publishDate |
2023 |
dc.date.accessioned.none.fl_str_mv |
2023-06-02T21:49:20Z |
dc.date.available.none.fl_str_mv |
2023-06-02T21:49:20Z |
dc.date.issued.none.fl_str_mv |
2023-06-01 |
dc.type.es_ES.fl_str_mv |
article |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.identifier.uri.none.fl_str_mv |
http://hdl.handle.net/10584/11547 |
url |
http://hdl.handle.net/10584/11547 |
dc.language.iso.es_ES.fl_str_mv |
spa |
language |
spa |
dc.rights.es_ES.fl_str_mv |
Universidad del Norte |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
rights_invalid_str_mv |
Universidad del Norte http://purl.org/coar/access_right/c_abf2 |
dc.publisher.es_ES.fl_str_mv |
Barranquilla, Universidad del Norte, 2023 |
institution |
Universidad del Norte |
bitstream.url.fl_str_mv |
https://manglar.uninorte.edu.co/bitstream/10584/11547/2/license.txt https://manglar.uninorte.edu.co/bitstream/10584/11547/1/PF_block_diagram.drawio_3.drawio.png |
bitstream.checksum.fl_str_mv |
8a4605be74aa9ea9d79846c1fba20a33 9cb2a89c559484793b9003c7d029959d |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Digital de la Universidad del Norte |
repository.mail.fl_str_mv |
mauribe@uninorte.edu.co |
_version_ |
1812183090634686464 |
spelling |
Gómez, DiegoClavijo, CarlosLinero Vassallo, Daniel Alfredo2023-06-02T21:49:20Z2023-06-02T21:49:20Z2023-06-01http://hdl.handle.net/10584/11547The Universidad del Norte has a pollution monitor located in an area that is difficult to access for the university community, making it difficult to obtain the data measured by it. A real-time acquisition system was designed where the data measured by the monitor are sent to a web server, where they are stored and displayed on a web page where graphs of these data are shown in addition to graphs and tables where historical values of energy consumption within the university are correlated. The system was designed using a Raspberry pi 4B microcontroller connected by serial communication to the monitor, the microcontroller was connected to an external GSM module to send the data received to the web server and displayed on a web page programmed with Javascript, PHP, HTML, and CSS. After the development, it was concluded that the system worked correctly sending and receiving data on the web page where you can view historical values, real-time data, and showing correlation graphs, redundancy was implemented in the system of receiving and displaying data to strengthen the designed system.La Universidad del Norte cuenta con un monitor de polución ubicado en una zona de difícil acceso para la comunidad universitaria, dificultando la obtención de los datos medidos por este. Se diseñó un sistema de adquisición a tiempo real donde los datos medidos por el monitor son enviados a un servidor web, donde son almacenados y visualizados en una pagina web donde se muestras graficas de estos datos en adición de gráficos y tablas donde se correlación valores históricos de consumo energético dentro de la universidad. Se diseñó el sistema usando un microcontrolador Raspberry pi 4B conectado por comunicación serial al monitor, el microntrolador se conectó a un modulo externo GSM para enviar los datos recibidos al servidor web y mostrados en una página web programada con Javascript, php, HTML y CSS. Posterior al desarrollo se concluyó que el sistema funcionó correctamente enviando y recibiendo los datos en la pagina web donde se puede visualizar valores históricos, datos a tiempo real y mostrando graficas de correlación se implementó redundancia en el sistema de recepción y visualización de los datos para fortalecer el sistema diseñado.spaBarranquilla, Universidad del Norte, 2023Universidad del Nortehttp://purl.org/coar/access_right/c_abf2VisualizaciónPlataformaPoluciónPolutionVisualizationPlatformDiseño e implementación de un sistema de gestión de información para la determinación de la calidad del aire en el campus de la Universidad del NorteDesign and implementation of an information management system for the determination of air quality on the Universidad del Norte campusarticlehttp://purl.org/coar/resource_type/c_6501LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://manglar.uninorte.edu.co/bitstream/10584/11547/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52ORIGINALPF_block_diagram.drawio_3.drawio.pngPF_block_diagram.drawio_3.drawio.pngDiagrama de bloques del prototipo diseñado.image/png38090https://manglar.uninorte.edu.co/bitstream/10584/11547/1/PF_block_diagram.drawio_3.drawio.png9cb2a89c559484793b9003c7d029959dMD5110584/11547oai:manglar.uninorte.edu.co:10584/115472023-06-02 16:49:21.239Repositorio Digital de la Universidad del Nortemauribe@uninorte.edu.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 |