Rediseño de las redes de distribución de aire acondicionado de buses de servicio público como estrategia de eficiencia energética y optimización del confort

In the transport industry, vehicle operating costs are an important issue to improve, in the same way thermal comfort for passenger inside a public transport bus (BRT) cabin represents a challenge, most likely in countries or cities with tropical climates such as Barranquilla. The main objective of...

Full description

Autores:
Arrieta Rueda, Maira Daniela
Hoz Oliveros, Juan Rafael de la
Salazar Sánchez, José Camilo
Tipo de recurso:
Fecha de publicación:
2020
Institución:
Universidad del Norte
Repositorio:
Repositorio Uninorte
Idioma:
spa
OAI Identifier:
oai:manglar.uninorte.edu.co:10584/8879
Acceso en línea:
http://hdl.handle.net/10584/8879
Palabra clave:
Confort, aire acondicionado, bus, eficiencia, CFD.
Comfort, air conditioning, bus, efficiency, CFD.
Rights
License
Universidad del Norte
id REPOUNORT2_34940aa1884bb78b0dc131fd0ea5565c
oai_identifier_str oai:manglar.uninorte.edu.co:10584/8879
network_acronym_str REPOUNORT2
network_name_str Repositorio Uninorte
repository_id_str
dc.title.es_ES.fl_str_mv Rediseño de las redes de distribución de aire acondicionado de buses de servicio público como estrategia de eficiencia energética y optimización del confort
dc.title.en_US.fl_str_mv Redesign of public service bus air conditioning distribution networks as an energy efficiency and comfort optimization strategy
title Rediseño de las redes de distribución de aire acondicionado de buses de servicio público como estrategia de eficiencia energética y optimización del confort
spellingShingle Rediseño de las redes de distribución de aire acondicionado de buses de servicio público como estrategia de eficiencia energética y optimización del confort
Confort, aire acondicionado, bus, eficiencia, CFD.
Comfort, air conditioning, bus, efficiency, CFD.
title_short Rediseño de las redes de distribución de aire acondicionado de buses de servicio público como estrategia de eficiencia energética y optimización del confort
title_full Rediseño de las redes de distribución de aire acondicionado de buses de servicio público como estrategia de eficiencia energética y optimización del confort
title_fullStr Rediseño de las redes de distribución de aire acondicionado de buses de servicio público como estrategia de eficiencia energética y optimización del confort
title_full_unstemmed Rediseño de las redes de distribución de aire acondicionado de buses de servicio público como estrategia de eficiencia energética y optimización del confort
title_sort Rediseño de las redes de distribución de aire acondicionado de buses de servicio público como estrategia de eficiencia energética y optimización del confort
dc.creator.fl_str_mv Arrieta Rueda, Maira Daniela
Hoz Oliveros, Juan Rafael de la
Salazar Sánchez, José Camilo
dc.contributor.advisor.none.fl_str_mv Corredor Martinez, Lesme Antonio
dc.contributor.author.none.fl_str_mv Arrieta Rueda, Maira Daniela
Hoz Oliveros, Juan Rafael de la
Salazar Sánchez, José Camilo
dc.subject.es_ES.fl_str_mv Confort, aire acondicionado, bus, eficiencia, CFD.
topic Confort, aire acondicionado, bus, eficiencia, CFD.
Comfort, air conditioning, bus, efficiency, CFD.
dc.subject.en_US.fl_str_mv Comfort, air conditioning, bus, efficiency, CFD.
description In the transport industry, vehicle operating costs are an important issue to improve, in the same way thermal comfort for passenger inside a public transport bus (BRT) cabin represents a challenge, most likely in countries or cities with tropical climates such as Barranquilla. The main objective of this project is to propose several modifications that lead to the improvement of the user thermal comfort conditions inside the cabin by revising and proposing solutions that generate a better conditioned air distribution networks, reducing fuel consumption and making the system more attractive for the users. In order to achieve this goal three design alternatives are proposed: flow discretization through dampers on the ducts accionated by a control system, total redesign of the air conducts including linear diffusers and load regulation considering the bus occupation and on the other hand as a third alternative, a compendium of tower type fans are proposed all through the cabin aiming to increase air turbulence. The total redesign alternative is chosen, this consists in the sizing of flexible ducts together with a flow distribution depending on the occupation with the purpose of improving internal thermal comfort conditions which is verified by CFD simulations. Finally, taking current operating conditions as a baseline, improved and recommended parameters by ASHRAE are possible to visualize, thermal comfort in critical zones was improved, the mean temperature in the cabin decreased from 27°C to 23°C, the relative humidity went from 53,6% to 51,9%, while the mean air shot velocity has increased from 2,5 m/s to 5 m/s. It is recommended to perform deeper and more complex CFD simulations looking forward to optimize the design and location of air distributing system elements and associate this kind of studies with technologies and refrigeration devices modifications.
publishDate 2020
dc.date.accessioned.none.fl_str_mv 2020-06-04T18:58:50Z
dc.date.available.none.fl_str_mv 2020-06-04T18:58:50Z
dc.date.issued.none.fl_str_mv 2020-06-03
dc.type.es_ES.fl_str_mv article
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/10584/8879
url http://hdl.handle.net/10584/8879
dc.language.iso.es_ES.fl_str_mv spa
language spa
dc.rights.es_ES.fl_str_mv Universidad del Norte
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Universidad del Norte
http://purl.org/coar/access_right/c_abf2
dc.publisher.es_ES.fl_str_mv Barranquilla, Universidad del Norte, 2020
institution Universidad del Norte
bitstream.url.fl_str_mv http://manglar.uninorte.edu.co/bitstream/10584/8879/4/CFD_Autobus.jpeg
http://manglar.uninorte.edu.co/bitstream/10584/8879/5/CFD_Bus.pdf
http://manglar.uninorte.edu.co/bitstream/10584/8879/6/license.txt
bitstream.checksum.fl_str_mv 9fbd135985a49c61628f06f95d0c9611
62616bb222425bd0dfb871f302c06a1e
8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Digital de la Universidad del Norte
repository.mail.fl_str_mv mauribe@uninorte.edu.co
_version_ 1812183088869933056
spelling Corredor Martinez, Lesme AntonioArrieta Rueda, Maira DanielaHoz Oliveros, Juan Rafael de laSalazar Sánchez, José Camilo2020-06-04T18:58:50Z2020-06-04T18:58:50Z2020-06-03http://hdl.handle.net/10584/8879In the transport industry, vehicle operating costs are an important issue to improve, in the same way thermal comfort for passenger inside a public transport bus (BRT) cabin represents a challenge, most likely in countries or cities with tropical climates such as Barranquilla. The main objective of this project is to propose several modifications that lead to the improvement of the user thermal comfort conditions inside the cabin by revising and proposing solutions that generate a better conditioned air distribution networks, reducing fuel consumption and making the system more attractive for the users. In order to achieve this goal three design alternatives are proposed: flow discretization through dampers on the ducts accionated by a control system, total redesign of the air conducts including linear diffusers and load regulation considering the bus occupation and on the other hand as a third alternative, a compendium of tower type fans are proposed all through the cabin aiming to increase air turbulence. The total redesign alternative is chosen, this consists in the sizing of flexible ducts together with a flow distribution depending on the occupation with the purpose of improving internal thermal comfort conditions which is verified by CFD simulations. Finally, taking current operating conditions as a baseline, improved and recommended parameters by ASHRAE are possible to visualize, thermal comfort in critical zones was improved, the mean temperature in the cabin decreased from 27°C to 23°C, the relative humidity went from 53,6% to 51,9%, while the mean air shot velocity has increased from 2,5 m/s to 5 m/s. It is recommended to perform deeper and more complex CFD simulations looking forward to optimize the design and location of air distributing system elements and associate this kind of studies with technologies and refrigeration devices modifications.Para el sector de transporte público es de vital importancia disminuir los costos operativos de los vehículos, de igual manera el confort térmico dentro de los autobuses representa un reto en ciudades con climas tropicales como Barranquilla. El principal objetivo del proyecto es proponer una serie de modificaciones que permitan mejorar las condiciones de confort térmico del usuario dentro de buses tipo padrón de sistema de transporte público al revisar y proponer soluciones para una mejor distribución de aire acondicionado, disminuyendo gastos por combustible y haciendo el sistema más atractivo para los usuarios. En busca de alcanzar este objetivo se establecen tres alternativas de diseño: La discretización del flujo a través de dampers accionados por un sistema de control, rediseño total de los ductos incluyendo difusores lineales y regulación de la carga operativa del sistema a partir de su ocupación y finalmente como última alternativa, la inclusión de ventiladores tipo torre para aumentar turbulencia. Se selecciona la solución que consiste en el dimensionamiento total de ductos flexibles de suministro de aire a lo largo de la cabina en conjunto con una discretización del flujo según ocupación, con el propósito de mejorar condiciones de confort internas, lo cual se verifica a través de simulaciones CFD. Finalmente tomando como línea base condiciones de operación actual de los autobuses, se logra constatar parámetros de confort mejorados y recomendados por ASHRAE, se logró optimizar el confort en las zonas críticas de bus y la temperatura promedio en cabina disminuyó de 27°C a 23°C, la humedad relativa disminuyó de 53,6% a 51,9% mientras que la velocidad de tiro promedio aumentó de 2,5 m/s a 5 m/s. Se recomienda realizar simulaciones CFD más complejas que permitan mejorar el diseño y ubicación de los elementos distribuidores de aire, así como acoplar este tipo de estudios con modificaciones en cuanto a las tecnologías y equipos de refrigeración utilizados.spaBarranquilla, Universidad del Norte, 2020Universidad del Nortehttp://purl.org/coar/access_right/c_abf2Confort, aire acondicionado, bus, eficiencia, CFD.Comfort, air conditioning, bus, efficiency, CFD.Rediseño de las redes de distribución de aire acondicionado de buses de servicio público como estrategia de eficiencia energética y optimización del confortRedesign of public service bus air conditioning distribution networks as an energy efficiency and comfort optimization strategyarticlehttp://purl.org/coar/resource_type/c_6501ORIGINALCFD_Autobus.jpegCFD_Autobus.jpegSimulación CFD para un autobusimage/jpeg71722http://manglar.uninorte.edu.co/bitstream/10584/8879/4/CFD_Autobus.jpeg9fbd135985a49c61628f06f95d0c9611MD54CFD_Bus.pdfCFD_Bus.pdfSimulación CFD para un autobusapplication/pdf125605http://manglar.uninorte.edu.co/bitstream/10584/8879/5/CFD_Bus.pdf62616bb222425bd0dfb871f302c06a1eMD55LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://manglar.uninorte.edu.co/bitstream/10584/8879/6/license.txt8a4605be74aa9ea9d79846c1fba20a33MD5610584/8879oai:manglar.uninorte.edu.co:10584/88792020-06-04 13:58:50.441Repositorio Digital de la Universidad del Nortemauribe@uninorte.edu.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