Correlation factor between standard surge waves for testing transient overvoltage suppressor devices

There is a varied number of standard impulse waves that are used to test the operation of transient surge suppressor devices. In particular, tests that check the maximum discharge pulse current are of importance. This paper analyzes the relationship between these different forms of impulsive waves,...

Full description

Autores:
Guillermo Zola, Julio
Tipo de recurso:
Fecha de publicación:
2008
Institución:
Universidad EAFIT
Repositorio:
Repositorio EAFIT
Idioma:
spa
OAI Identifier:
oai:repository.eafit.edu.co:10784/14530
Acceso en línea:
http://hdl.handle.net/10784/14530
Palabra clave:
Impulse Current
Transient Overvoltage
Device
Corriente Impulsiva
Sobretensión Transitoria
Dispositivo
Rights
License
Copyright (c) 2008 Julio Guillermo Zola
id REPOEAFIT2_c8f146ccec04fa856bbc04f9fe0bb182
oai_identifier_str oai:repository.eafit.edu.co:10784/14530
network_acronym_str REPOEAFIT2
network_name_str Repositorio EAFIT
repository_id_str
spelling Medellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degrees2008-06-102019-11-22T19:10:49Z2008-06-102019-11-22T19:10:49Z2256-43141794-9165http://hdl.handle.net/10784/14530There is a varied number of standard impulse waves that are used to test the operation of transient surge suppressor devices. In particular, tests that check the maximum discharge pulse current are of importance. This paper analyzes the relationship between these different forms of impulsive waves, in order to obtain a correlation between them to apply one or the other with similar results. The conclusions reached from a simplified theoretical development are corroborated by laboratory measurement and simulation.Existe un variado número de ondas impulsivas estándar que se utilizan para ensayar el funcionamiento de los dispositivos supresores de sobretensiones transitorias. En particular, resultan de importancia los ensayos que comprueban la corriente máxima de impulso de descarga. Se analiza en este trabajo la relación existente entre estas distintas formas de ondas impulsivas, de forma tal de poder obtener una correlación entre ellas para aplicar una u otra con similares resultados. Las conclusiones que se alcanzan a partir de un desarrollo teórico simplificado son corroboradas mediante medición en laboratorio y simulación.application/pdfspaUniversidad EAFIThttp://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/234http://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/234Copyright (c) 2008 Julio Guillermo ZolaAcceso abiertohttp://purl.org/coar/access_right/c_abf2instname:Universidad EAFITreponame:Repositorio Institucional Universidad EAFITIngeniería y Ciencia; Vol 4, No 7 (2008)Correlation factor between standard surge waves for testing transient overvoltage suppressor devicesCorrelación entre ondas de ensayo para dispositivos supresores de sobretensionesarticleinfo:eu-repo/semantics/articlepublishedVersioninfo:eu-repo/semantics/publishedVersionArtículohttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1Impulse CurrentTransient OvervoltageDeviceCorriente ImpulsivaSobretensión TransitoriaDispositivoGuillermo Zola, JulioUniversidad de Buenos AiresIngeniería y Ciencia47113128ing.cienc.THUMBNAILminaitura-ig_Mesa de trabajo 1.jpgminaitura-ig_Mesa de trabajo 1.jpgimage/jpeg265796https://repository.eafit.edu.co/bitstreams/3723854e-3e35-460e-bad9-f2f561cdc262/downloadda9b21a5c7e00c7f1127cef8e97035e0MD51ORIGINAL6.pdf6.pdfTexto completo PDFapplication/pdf651604https://repository.eafit.edu.co/bitstreams/7b1306d1-89bd-47a7-843d-2062e77d34c9/download5ce561cbbdda55af04b7c76afa66ce4bMD52articulo.htmlarticulo.htmlTexto completo HTMLtext/html373https://repository.eafit.edu.co/bitstreams/f9ca42c1-d810-46bf-bd85-b9ed17170a10/downloada6070b99dda743f8b5c7d347b23cc0b0MD5310784/14530oai:repository.eafit.edu.co:10784/145302020-03-02 23:13:27.192open.accesshttps://repository.eafit.edu.coRepositorio Institucional Universidad EAFITrepositorio@eafit.edu.co
dc.title.eng.fl_str_mv Correlation factor between standard surge waves for testing transient overvoltage suppressor devices
dc.title.spa.fl_str_mv Correlación entre ondas de ensayo para dispositivos supresores de sobretensiones
title Correlation factor between standard surge waves for testing transient overvoltage suppressor devices
spellingShingle Correlation factor between standard surge waves for testing transient overvoltage suppressor devices
Impulse Current
Transient Overvoltage
Device
Corriente Impulsiva
Sobretensión Transitoria
Dispositivo
title_short Correlation factor between standard surge waves for testing transient overvoltage suppressor devices
title_full Correlation factor between standard surge waves for testing transient overvoltage suppressor devices
title_fullStr Correlation factor between standard surge waves for testing transient overvoltage suppressor devices
title_full_unstemmed Correlation factor between standard surge waves for testing transient overvoltage suppressor devices
title_sort Correlation factor between standard surge waves for testing transient overvoltage suppressor devices
dc.creator.fl_str_mv Guillermo Zola, Julio
dc.contributor.author.spa.fl_str_mv Guillermo Zola, Julio
dc.contributor.affiliation.spa.fl_str_mv Universidad de Buenos Aires
dc.subject.keyword.eng.fl_str_mv Impulse Current
Transient Overvoltage
Device
topic Impulse Current
Transient Overvoltage
Device
Corriente Impulsiva
Sobretensión Transitoria
Dispositivo
dc.subject.keyword.spa.fl_str_mv Corriente Impulsiva
Sobretensión Transitoria
Dispositivo
description There is a varied number of standard impulse waves that are used to test the operation of transient surge suppressor devices. In particular, tests that check the maximum discharge pulse current are of importance. This paper analyzes the relationship between these different forms of impulsive waves, in order to obtain a correlation between them to apply one or the other with similar results. The conclusions reached from a simplified theoretical development are corroborated by laboratory measurement and simulation.
publishDate 2008
dc.date.issued.none.fl_str_mv 2008-06-10
dc.date.available.none.fl_str_mv 2019-11-22T19:10:49Z
dc.date.accessioned.none.fl_str_mv 2019-11-22T19:10:49Z
dc.date.none.fl_str_mv 2008-06-10
dc.type.eng.fl_str_mv article
info:eu-repo/semantics/article
publishedVersion
info:eu-repo/semantics/publishedVersion
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_6501
http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.local.spa.fl_str_mv Artículo
status_str publishedVersion
dc.identifier.issn.none.fl_str_mv 2256-4314
1794-9165
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/10784/14530
identifier_str_mv 2256-4314
1794-9165
url http://hdl.handle.net/10784/14530
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.isversionof.none.fl_str_mv http://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/234
dc.relation.uri.none.fl_str_mv http://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/234
dc.rights.eng.fl_str_mv Copyright (c) 2008 Julio Guillermo Zola
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.local.spa.fl_str_mv Acceso abierto
rights_invalid_str_mv Copyright (c) 2008 Julio Guillermo Zola
Acceso abierto
http://purl.org/coar/access_right/c_abf2
dc.format.none.fl_str_mv application/pdf
dc.coverage.spatial.eng.fl_str_mv Medellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degrees
dc.publisher.spa.fl_str_mv Universidad EAFIT
dc.source.none.fl_str_mv instname:Universidad EAFIT
reponame:Repositorio Institucional Universidad EAFIT
dc.source.spa.fl_str_mv Ingeniería y Ciencia; Vol 4, No 7 (2008)
instname_str Universidad EAFIT
institution Universidad EAFIT
reponame_str Repositorio Institucional Universidad EAFIT
collection Repositorio Institucional Universidad EAFIT
bitstream.url.fl_str_mv https://repository.eafit.edu.co/bitstreams/3723854e-3e35-460e-bad9-f2f561cdc262/download
https://repository.eafit.edu.co/bitstreams/7b1306d1-89bd-47a7-843d-2062e77d34c9/download
https://repository.eafit.edu.co/bitstreams/f9ca42c1-d810-46bf-bd85-b9ed17170a10/download
bitstream.checksum.fl_str_mv da9b21a5c7e00c7f1127cef8e97035e0
5ce561cbbdda55af04b7c76afa66ce4b
a6070b99dda743f8b5c7d347b23cc0b0
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad EAFIT
repository.mail.fl_str_mv repositorio@eafit.edu.co
_version_ 1814110177997094912