Al2O3 sintered pellets as thermoluminescent dosimeters

Verification of the radiation dose received by the area exposed during medical treatment is essential for the evaluation of any radiotherapy regimen.This work describes the thermoluminescent (TL) characteristics of sintered Al2O3 tablets, for possible use as a low dose dosimeter dose. Al2O3 tablets...

Full description

Autores:
Osorio, Amalia
Salcedo, Juana
Cogollo, Rafael
Tipo de recurso:
Fecha de publicación:
2012
Institución:
Universidad EAFIT
Repositorio:
Repositorio EAFIT
Idioma:
eng
OAI Identifier:
oai:repository.eafit.edu.co:10784/14438
Acceso en línea:
http://hdl.handle.net/10784/14438
Palabra clave:
Al2O3
Dosimetry
Thermoluminescence
Al2O3
Dosimetría
Termoluminiscencia
Rights
License
Copyright (c) 2012 Amalia Osorio, Juana Salcedo, Rafael Cogollo
id REPOEAFIT2_49dde2d69e4ade13cfd709db5e0a25e2
oai_identifier_str oai:repository.eafit.edu.co:10784/14438
network_acronym_str REPOEAFIT2
network_name_str Repositorio EAFIT
repository_id_str
dc.title.eng.fl_str_mv Al2O3 sintered pellets as thermoluminescent dosimeters
dc.title.spa.fl_str_mv Pastillas sinterizadas de Al2O3 como dosímetros termoluminiscentes
title Al2O3 sintered pellets as thermoluminescent dosimeters
spellingShingle Al2O3 sintered pellets as thermoluminescent dosimeters
Al2O3
Dosimetry
Thermoluminescence
Al2O3
Dosimetría
Termoluminiscencia
title_short Al2O3 sintered pellets as thermoluminescent dosimeters
title_full Al2O3 sintered pellets as thermoluminescent dosimeters
title_fullStr Al2O3 sintered pellets as thermoluminescent dosimeters
title_full_unstemmed Al2O3 sintered pellets as thermoluminescent dosimeters
title_sort Al2O3 sintered pellets as thermoluminescent dosimeters
dc.creator.fl_str_mv Osorio, Amalia
Salcedo, Juana
Cogollo, Rafael
dc.contributor.author.spa.fl_str_mv Osorio, Amalia
Salcedo, Juana
Cogollo, Rafael
dc.contributor.affiliation.spa.fl_str_mv Universidad de Córdoba
dc.subject.keyword.eng.fl_str_mv Al2O3
Dosimetry
Thermoluminescence
topic Al2O3
Dosimetry
Thermoluminescence
Al2O3
Dosimetría
Termoluminiscencia
dc.subject.keyword.spa.fl_str_mv Al2O3
Dosimetría
Termoluminiscencia
description Verification of the radiation dose received by the area exposed during medical treatment is essential for the evaluation of any radiotherapy regimen.This work describes the thermoluminescent (TL) characteristics of sintered Al2O3 tablets, for possible use as a low dose dosimeter dose. Al2O3 tablets sintered under different calcination conditions, with a diameter of 5 mm and a thickness of 1 mm, were irradiated at different doses using a 60Co Theratron 780Cr enaire unit at room temperature. The reading was done on a Harshaw TLD 4500.The main dosimetric properties of the material (brightness curve, response reproducibility, reuse, linearity and thermal decay) have been studied in detail. The brightness curve of the Al2O3 sintered pellets has an intense TL peak around 165C, which can be used for dosimetry. The results show that the pills can be used in quality control programs such as a thermoluminescent dosimeter in the therapeutic dose range. The importance of this work is that aluminum oxide (−Al2O3) is a promising alternative within TL materials used for “in vivo” dosimetry within quality control programs.
publishDate 2012
dc.date.issued.none.fl_str_mv 2012-06-15
dc.date.available.none.fl_str_mv 2019-11-22T18:48:57Z
dc.date.accessioned.none.fl_str_mv 2019-11-22T18:48:57Z
dc.date.none.fl_str_mv 2012-06-15
dc.type.eng.fl_str_mv article
info:eu-repo/semantics/article
publishedVersion
info:eu-repo/semantics/publishedVersion
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_6501
http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.local.spa.fl_str_mv Artículo
status_str publishedVersion
dc.identifier.issn.none.fl_str_mv 2256-4314
1794-9165
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/10784/14438
dc.identifier.doi.none.fl_str_mv 10.17230/ingciencia.8.15.3
identifier_str_mv 2256-4314
1794-9165
10.17230/ingciencia.8.15.3
url http://hdl.handle.net/10784/14438
dc.language.iso.eng.fl_str_mv eng
language eng
dc.relation.isversionof.none.fl_str_mv http://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/934
dc.relation.uri.none.fl_str_mv http://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/934
dc.rights.eng.fl_str_mv Copyright (c) 2012 Amalia Osorio, Juana Salcedo, Rafael Cogollo
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.local.spa.fl_str_mv Acceso abierto
rights_invalid_str_mv Copyright (c) 2012 Amalia Osorio, Juana Salcedo, Rafael Cogollo
Acceso abierto
http://purl.org/coar/access_right/c_abf2
dc.format.none.fl_str_mv application/pdf
dc.coverage.spatial.eng.fl_str_mv Medellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degrees
dc.publisher.spa.fl_str_mv Universidad EAFIT
dc.source.none.fl_str_mv instname:Universidad EAFIT
reponame:Repositorio Institucional Universidad EAFIT
dc.source.spa.fl_str_mv Ingeniería y Ciencia; Vol 8, No 15 (2012)
instname_str Universidad EAFIT
institution Universidad EAFIT
reponame_str Repositorio Institucional Universidad EAFIT
collection Repositorio Institucional Universidad EAFIT
bitstream.url.fl_str_mv https://repository.eafit.edu.co/bitstreams/c17bd870-f6b0-4269-bf8d-8a18dcb5bbcc/download
https://repository.eafit.edu.co/bitstreams/ad159202-71c4-49d6-941f-19c99e130c2a/download
https://repository.eafit.edu.co/bitstreams/02cf0acd-8e1a-4880-b359-cc59ae600738/download
bitstream.checksum.fl_str_mv 3088291e6b95492d05e1ae396a07de8d
6196954f3aa09283f9ea28f225895673
da9b21a5c7e00c7f1127cef8e97035e0
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad EAFIT
repository.mail.fl_str_mv repositorio@eafit.edu.co
_version_ 1808498919110344704
spelling Medellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degrees2012-06-152019-11-22T18:48:57Z2012-06-152019-11-22T18:48:57Z2256-43141794-9165http://hdl.handle.net/10784/1443810.17230/ingciencia.8.15.3Verification of the radiation dose received by the area exposed during medical treatment is essential for the evaluation of any radiotherapy regimen.This work describes the thermoluminescent (TL) characteristics of sintered Al2O3 tablets, for possible use as a low dose dosimeter dose. Al2O3 tablets sintered under different calcination conditions, with a diameter of 5 mm and a thickness of 1 mm, were irradiated at different doses using a 60Co Theratron 780Cr enaire unit at room temperature. The reading was done on a Harshaw TLD 4500.The main dosimetric properties of the material (brightness curve, response reproducibility, reuse, linearity and thermal decay) have been studied in detail. The brightness curve of the Al2O3 sintered pellets has an intense TL peak around 165C, which can be used for dosimetry. The results show that the pills can be used in quality control programs such as a thermoluminescent dosimeter in the therapeutic dose range. The importance of this work is that aluminum oxide (−Al2O3) is a promising alternative within TL materials used for “in vivo” dosimetry within quality control programs.La verificación de la dosis de radiación recibida por el área expuesta durante eltratamiento médico es esencial para la evaluación de cualquier régimen de radioterapia.Este trabajo describe las caracteríısticas termoluminiscentes (TL)de pastillas sinterizadas de Al2O3, para su posible uso como dosímetro TL de baja dosis. Pastillas de Al2O3 sinterizadas bajo diferentes condiciones decalcinación, con un diámetro de 5 mm y un espesor de 1 mm, fueron irradiadasa diferentes dosis usando una unidad de 60Co Theratron 780Cr enaire a temperatura ambiente. La lectura se realizó en un Harshaw TLD 4500.Las principales propiedades dosimétricas del material (curva de brillo, reproducibilidadde la respuesta, reutilización, linealidad y decaimiento térmico)han sido estudiadas en detalle. La curva de brillo de las pastillas sinterizadasde Al2O3 presenta un intenso pico TL alrededor de los 165C, el cual puede ser usado para dosimetría. Los resultados muestran que las pastillas pueden serusadas en programas de control de calidad como dosímetro termoluminiscenteen el rango de dosis terapéuticas. La importancia de este trabajo radica en que el óxido de aluminio (−Al2O3) es una alternativa prometedora dentrode los materiales TL usados para dosimetría “in vivo”dentro de los programasde control de calidad.application/pdfengUniversidad EAFIThttp://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/934http://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/934Copyright (c) 2012 Amalia Osorio, Juana Salcedo, Rafael CogolloAcceso abiertohttp://purl.org/coar/access_right/c_abf2instname:Universidad EAFITreponame:Repositorio Institucional Universidad EAFITIngeniería y Ciencia; Vol 8, No 15 (2012)Al2O3 sintered pellets as thermoluminescent dosimetersPastillas sinterizadas de Al2O3 como dosímetros termoluminiscentesarticleinfo:eu-repo/semantics/articlepublishedVersioninfo:eu-repo/semantics/publishedVersionArtículohttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1Al2O3DosimetryThermoluminescenceAl2O3DosimetríaTermoluminiscenciaOsorio, AmaliaSalcedo, JuanaCogollo, RafaelUniversidad de CórdobaIngeniería y Ciencia8154764ing.cienc.ORIGINAL3.pdf3.pdfTexto completo PDFapplication/pdf528646https://repository.eafit.edu.co/bitstreams/c17bd870-f6b0-4269-bf8d-8a18dcb5bbcc/download3088291e6b95492d05e1ae396a07de8dMD51articulo.htmlarticulo.htmlTexto completo HTMLtext/html373https://repository.eafit.edu.co/bitstreams/ad159202-71c4-49d6-941f-19c99e130c2a/download6196954f3aa09283f9ea28f225895673MD53THUMBNAILminaitura-ig_Mesa de trabajo 1.jpgminaitura-ig_Mesa de trabajo 1.jpgimage/jpeg265796https://repository.eafit.edu.co/bitstreams/02cf0acd-8e1a-4880-b359-cc59ae600738/downloadda9b21a5c7e00c7f1127cef8e97035e0MD5210784/14438oai:repository.eafit.edu.co:10784/144382020-03-02 22:00:01.654open.accesshttps://repository.eafit.edu.coRepositorio Institucional Universidad EAFITrepositorio@eafit.edu.co