Al2O3 sintered pellets as thermoluminescent dosimeters
Verification of the radiation dose received by the area exposed during medical treatment is essential for the evaluation of any radiotherapy regimen.This work describes the thermoluminescent (TL) characteristics of sintered Al2O3 tablets, for possible use as a low dose dosimeter dose. Al2O3 tablets...
- Autores:
-
Osorio, Amalia
Salcedo, Juana
Cogollo, Rafael
- Tipo de recurso:
- Fecha de publicación:
- 2012
- Institución:
- Universidad EAFIT
- Repositorio:
- Repositorio EAFIT
- Idioma:
- eng
- OAI Identifier:
- oai:repository.eafit.edu.co:10784/14438
- Acceso en línea:
- http://hdl.handle.net/10784/14438
- Palabra clave:
- Al2O3
Dosimetry
Thermoluminescence
Al2O3
Dosimetría
Termoluminiscencia
- Rights
- License
- Copyright (c) 2012 Amalia Osorio, Juana Salcedo, Rafael Cogollo
id |
REPOEAFIT2_49dde2d69e4ade13cfd709db5e0a25e2 |
---|---|
oai_identifier_str |
oai:repository.eafit.edu.co:10784/14438 |
network_acronym_str |
REPOEAFIT2 |
network_name_str |
Repositorio EAFIT |
repository_id_str |
|
dc.title.eng.fl_str_mv |
Al2O3 sintered pellets as thermoluminescent dosimeters |
dc.title.spa.fl_str_mv |
Pastillas sinterizadas de Al2O3 como dosímetros termoluminiscentes |
title |
Al2O3 sintered pellets as thermoluminescent dosimeters |
spellingShingle |
Al2O3 sintered pellets as thermoluminescent dosimeters Al2O3 Dosimetry Thermoluminescence Al2O3 Dosimetría Termoluminiscencia |
title_short |
Al2O3 sintered pellets as thermoluminescent dosimeters |
title_full |
Al2O3 sintered pellets as thermoluminescent dosimeters |
title_fullStr |
Al2O3 sintered pellets as thermoluminescent dosimeters |
title_full_unstemmed |
Al2O3 sintered pellets as thermoluminescent dosimeters |
title_sort |
Al2O3 sintered pellets as thermoluminescent dosimeters |
dc.creator.fl_str_mv |
Osorio, Amalia Salcedo, Juana Cogollo, Rafael |
dc.contributor.author.spa.fl_str_mv |
Osorio, Amalia Salcedo, Juana Cogollo, Rafael |
dc.contributor.affiliation.spa.fl_str_mv |
Universidad de Córdoba |
dc.subject.keyword.eng.fl_str_mv |
Al2O3 Dosimetry Thermoluminescence |
topic |
Al2O3 Dosimetry Thermoluminescence Al2O3 Dosimetría Termoluminiscencia |
dc.subject.keyword.spa.fl_str_mv |
Al2O3 Dosimetría Termoluminiscencia |
description |
Verification of the radiation dose received by the area exposed during medical treatment is essential for the evaluation of any radiotherapy regimen.This work describes the thermoluminescent (TL) characteristics of sintered Al2O3 tablets, for possible use as a low dose dosimeter dose. Al2O3 tablets sintered under different calcination conditions, with a diameter of 5 mm and a thickness of 1 mm, were irradiated at different doses using a 60Co Theratron 780Cr enaire unit at room temperature. The reading was done on a Harshaw TLD 4500.The main dosimetric properties of the material (brightness curve, response reproducibility, reuse, linearity and thermal decay) have been studied in detail. The brightness curve of the Al2O3 sintered pellets has an intense TL peak around 165C, which can be used for dosimetry. The results show that the pills can be used in quality control programs such as a thermoluminescent dosimeter in the therapeutic dose range. The importance of this work is that aluminum oxide (−Al2O3) is a promising alternative within TL materials used for “in vivo” dosimetry within quality control programs. |
publishDate |
2012 |
dc.date.issued.none.fl_str_mv |
2012-06-15 |
dc.date.available.none.fl_str_mv |
2019-11-22T18:48:57Z |
dc.date.accessioned.none.fl_str_mv |
2019-11-22T18:48:57Z |
dc.date.none.fl_str_mv |
2012-06-15 |
dc.type.eng.fl_str_mv |
article info:eu-repo/semantics/article publishedVersion info:eu-repo/semantics/publishedVersion |
dc.type.coarversion.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.local.spa.fl_str_mv |
Artículo |
status_str |
publishedVersion |
dc.identifier.issn.none.fl_str_mv |
2256-4314 1794-9165 |
dc.identifier.uri.none.fl_str_mv |
http://hdl.handle.net/10784/14438 |
dc.identifier.doi.none.fl_str_mv |
10.17230/ingciencia.8.15.3 |
identifier_str_mv |
2256-4314 1794-9165 10.17230/ingciencia.8.15.3 |
url |
http://hdl.handle.net/10784/14438 |
dc.language.iso.eng.fl_str_mv |
eng |
language |
eng |
dc.relation.isversionof.none.fl_str_mv |
http://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/934 |
dc.relation.uri.none.fl_str_mv |
http://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/934 |
dc.rights.eng.fl_str_mv |
Copyright (c) 2012 Amalia Osorio, Juana Salcedo, Rafael Cogollo |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.local.spa.fl_str_mv |
Acceso abierto |
rights_invalid_str_mv |
Copyright (c) 2012 Amalia Osorio, Juana Salcedo, Rafael Cogollo Acceso abierto http://purl.org/coar/access_right/c_abf2 |
dc.format.none.fl_str_mv |
application/pdf |
dc.coverage.spatial.eng.fl_str_mv |
Medellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degrees |
dc.publisher.spa.fl_str_mv |
Universidad EAFIT |
dc.source.none.fl_str_mv |
instname:Universidad EAFIT reponame:Repositorio Institucional Universidad EAFIT |
dc.source.spa.fl_str_mv |
Ingeniería y Ciencia; Vol 8, No 15 (2012) |
instname_str |
Universidad EAFIT |
institution |
Universidad EAFIT |
reponame_str |
Repositorio Institucional Universidad EAFIT |
collection |
Repositorio Institucional Universidad EAFIT |
bitstream.url.fl_str_mv |
https://repository.eafit.edu.co/bitstreams/c17bd870-f6b0-4269-bf8d-8a18dcb5bbcc/download https://repository.eafit.edu.co/bitstreams/ad159202-71c4-49d6-941f-19c99e130c2a/download https://repository.eafit.edu.co/bitstreams/02cf0acd-8e1a-4880-b359-cc59ae600738/download |
bitstream.checksum.fl_str_mv |
3088291e6b95492d05e1ae396a07de8d 6196954f3aa09283f9ea28f225895673 da9b21a5c7e00c7f1127cef8e97035e0 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad EAFIT |
repository.mail.fl_str_mv |
repositorio@eafit.edu.co |
_version_ |
1818102431654871040 |
spelling |
Medellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degrees2012-06-152019-11-22T18:48:57Z2012-06-152019-11-22T18:48:57Z2256-43141794-9165http://hdl.handle.net/10784/1443810.17230/ingciencia.8.15.3Verification of the radiation dose received by the area exposed during medical treatment is essential for the evaluation of any radiotherapy regimen.This work describes the thermoluminescent (TL) characteristics of sintered Al2O3 tablets, for possible use as a low dose dosimeter dose. Al2O3 tablets sintered under different calcination conditions, with a diameter of 5 mm and a thickness of 1 mm, were irradiated at different doses using a 60Co Theratron 780Cr enaire unit at room temperature. The reading was done on a Harshaw TLD 4500.The main dosimetric properties of the material (brightness curve, response reproducibility, reuse, linearity and thermal decay) have been studied in detail. The brightness curve of the Al2O3 sintered pellets has an intense TL peak around 165C, which can be used for dosimetry. The results show that the pills can be used in quality control programs such as a thermoluminescent dosimeter in the therapeutic dose range. The importance of this work is that aluminum oxide (−Al2O3) is a promising alternative within TL materials used for “in vivo” dosimetry within quality control programs.La verificación de la dosis de radiación recibida por el área expuesta durante eltratamiento médico es esencial para la evaluación de cualquier régimen de radioterapia.Este trabajo describe las caracteríısticas termoluminiscentes (TL)de pastillas sinterizadas de Al2O3, para su posible uso como dosímetro TL de baja dosis. Pastillas de Al2O3 sinterizadas bajo diferentes condiciones decalcinación, con un diámetro de 5 mm y un espesor de 1 mm, fueron irradiadasa diferentes dosis usando una unidad de 60Co Theratron 780Cr enaire a temperatura ambiente. La lectura se realizó en un Harshaw TLD 4500.Las principales propiedades dosimétricas del material (curva de brillo, reproducibilidadde la respuesta, reutilización, linealidad y decaimiento térmico)han sido estudiadas en detalle. La curva de brillo de las pastillas sinterizadasde Al2O3 presenta un intenso pico TL alrededor de los 165C, el cual puede ser usado para dosimetría. Los resultados muestran que las pastillas pueden serusadas en programas de control de calidad como dosímetro termoluminiscenteen el rango de dosis terapéuticas. La importancia de este trabajo radica en que el óxido de aluminio (−Al2O3) es una alternativa prometedora dentrode los materiales TL usados para dosimetría “in vivo”dentro de los programasde control de calidad.application/pdfengUniversidad EAFIThttp://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/934http://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/934Copyright (c) 2012 Amalia Osorio, Juana Salcedo, Rafael CogolloAcceso abiertohttp://purl.org/coar/access_right/c_abf2instname:Universidad EAFITreponame:Repositorio Institucional Universidad EAFITIngeniería y Ciencia; Vol 8, No 15 (2012)Al2O3 sintered pellets as thermoluminescent dosimetersPastillas sinterizadas de Al2O3 como dosímetros termoluminiscentesarticleinfo:eu-repo/semantics/articlepublishedVersioninfo:eu-repo/semantics/publishedVersionArtículohttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1Al2O3DosimetryThermoluminescenceAl2O3DosimetríaTermoluminiscenciaOsorio, Amalia6e45fa41-6f43-49be-8924-d8290e715177-1Salcedo, Juana63b9e51c-64c6-4028-a1a6-0e18c19d9a50-1Cogollo, Rafael34d1b454-d93b-4f17-9f87-99aedac2b511-1Universidad de CórdobaIngeniería y Ciencia8154764ing.cienc.ORIGINAL3.pdf3.pdfTexto completo PDFapplication/pdf528646https://repository.eafit.edu.co/bitstreams/c17bd870-f6b0-4269-bf8d-8a18dcb5bbcc/download3088291e6b95492d05e1ae396a07de8dMD51articulo.htmlarticulo.htmlTexto completo HTMLtext/html373https://repository.eafit.edu.co/bitstreams/ad159202-71c4-49d6-941f-19c99e130c2a/download6196954f3aa09283f9ea28f225895673MD53THUMBNAILminaitura-ig_Mesa de trabajo 1.jpgminaitura-ig_Mesa de trabajo 1.jpgimage/jpeg265796https://repository.eafit.edu.co/bitstreams/02cf0acd-8e1a-4880-b359-cc59ae600738/downloadda9b21a5c7e00c7f1127cef8e97035e0MD5210784/14438oai:repository.eafit.edu.co:10784/144382024-12-04 11:49:59.387open.accesshttps://repository.eafit.edu.coRepositorio Institucional Universidad EAFITrepositorio@eafit.edu.co |