Understanding the extraction capabilities of the Helix Supercritical Fluid System
Supercritical fluids extraction is a separation technique, which has higher yields and lower extraction times than conventional extraction techniques -- Moreover, due to the general use of carbon dioxide a supercritical medium there is also a reduction in the use of toxic organic solvents -- Althoug...
- Autores:
-
Guzmán Aristizábal, Paola Andrea
- Tipo de recurso:
- Fecha de publicación:
- 2018
- Institución:
- Universidad EAFIT
- Repositorio:
- Repositorio EAFIT
- Idioma:
- spa
- OAI Identifier:
- oai:repository.eafit.edu.co:10784/13132
- Acceso en línea:
- http://hdl.handle.net/10784/13132
- Palabra clave:
- Fluidos supercríticos
Sistema Helix
TECNOLOGÍA QUÍMICA
GLUCÓSIDOS
STEVIA
SEPARACIÓN (TECNOLOGÍA)
Chemistry, Technical
Stevia
Separation (technology)
- Rights
- License
- Acceso abierto
Summary: | Supercritical fluids extraction is a separation technique, which has higher yields and lower extraction times than conventional extraction techniques -- Moreover, due to the general use of carbon dioxide a supercritical medium there is also a reduction in the use of toxic organic solvents -- Although there are commercial supercritical fluid extraction systems, these systems are not standardized, and each different system has its own particularities -- At Universidad EAFIT there is a new supercritical fluid equipment, a Helix model of Applied Separations, that has not been thoroughly tested for its operation -- The extraction of glycosides from stevia was used as a model for understanding the effect of different parameters, such as pressure, temperature, CO2 flow, matrix load and extraction time, on the operation the Helix system at EAFIT University -- The effect of the changes in the variables was evaluated by calculating extraction yield and by characterization of the extract -- The obtained extract was characterized by IR and HPLC to verify the extraction of glycosides -- As a result of this project an operation manual for the equipment was written -- Pressure seems to be the more influential operating parameter, both for the matrix extraction and equipment performance -- Pressure and temperature have repercussions on other process variables as preparing, extraction and cleaning time or 2 consumption -- However, all the evaluated operating parameters represent a contribution for the equipment performance and their understanding is essential for improved capability of Helix system -- A maximum yield of 1.4% was obtained -- Pressure was the most important variable on the glycosides extraction yield, while the temperature did not have a noticeable effect on the yield -- Similarly, the use of cosolvent remarkably improved the performance at same conditions of pressure and temperature -- An approximate extraction time of 120 minutes was required |
---|