Sand as thermoluminescent dosimeter to therapeutic doses

This work describes the thermoluminescent characteristics of sand from Coveñas beaches for use as a dosimeter in therapeutic doses. Selected samples, heat treated at 400 ° C for one hour, were irradiated at different doses using a 60Co Theratron 780C unit in air at room temperature. The reading was...

Full description

Autores:
Ricaurte, Daniel
Salcedo, Juana
Cogollo, Rafael
Tipo de recurso:
Fecha de publicación:
2010
Institución:
Universidad EAFIT
Repositorio:
Repositorio EAFIT
Idioma:
spa
OAI Identifier:
oai:repository.eafit.edu.co:10784/14491
Acceso en línea:
http://hdl.handle.net/10784/14491
Palabra clave:
Sand
Thermoluminescence
Dosimetry
Arena
Termoluminiscencia
Dosimetría
Rights
License
Copyright (c) 2010 Daniel Ricaurte, Juana Salcedo, Rafael Cogollo
id REPOEAFIT2_013db59a372b0cdce4fab4627c0407c0
oai_identifier_str oai:repository.eafit.edu.co:10784/14491
network_acronym_str REPOEAFIT2
network_name_str Repositorio EAFIT
repository_id_str
spelling Medellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degrees2010-06-012019-11-22T19:01:25Z2010-06-012019-11-22T19:01:25Z2256-43141794-9165http://hdl.handle.net/10784/14491This work describes the thermoluminescent characteristics of sand from Coveñas beaches for use as a dosimeter in therapeutic doses. Selected samples, heat treated at 400 ° C for one hour, were irradiated at different doses using a 60Co Theratron 780C unit in air at room temperature. The reading was done on a Harshaw TLD 4500. The main dosimetric properties of the material (brightness curve, response reproducibility, reuse, linearity and thermal decay) have been studied in detail. The brightness curve of the sand samples has a TL peak around 145 ° C. The results show that the material has a linear response with the dose from 50 cGy to 1000 cGy. The sand samples studied can be used as thermoluminescent dosimeters for applications in different areas. The importance of this work is that sand is a natural substance available in large quantities, has low cost and can be used in clinical physics to evaluate the dose received by the patient during medical treatment.Este trabajo describe las características termoluminiscentes de arena proveniente de las playas de Coveñas para su uso como dosímetro en dosis terapéuticas. Las muestras seleccionadas, tratadas térmicamente a 400◦C por una hora, fueron irradiadas a diferentes dosis usando una unidad de 60Co Theratron 780C en aire a temperatura ambiente. La lectura se realizó en un Harshaw TLD 4500. Las principales propiedades dosimétricas del material (curva de brillo, reproducibilidad de la respuesta, reutilización, linealidad y decaimiento térmico) han sido estudiadas en detalle. La curva de brillo de las muestras de arena presenta un pico TL alrededor de los 145◦C. Los resultados muestran que el material tiene una respuesta lineal con la dosis desde 50 cGy hasta 1000 cGy. Las muestras de arena estudiadas se pueden utilizar como dos´ımetros termoluminiscentes para aplicaciones en diferentes áreas. La importancia de este trabajo radica en que la arena es una sustancia natural disponible en grandes cantidades, tiene bajo costo y puede usarse en física clínica para evaluar la dosis recibida por el paciente durante el tratamiento médico.application/pdfspaUniversidad EAFIThttp://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/247http://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/247Copyright (c) 2010 Daniel Ricaurte, Juana Salcedo, Rafael CogolloAcceso abiertohttp://purl.org/coar/access_right/c_abf2instname:Universidad EAFITreponame:Repositorio Institucional Universidad EAFITIngeniería y Ciencia; Vol 6, No 11 (2010)Sand as thermoluminescent dosimeter to therapeutic dosesArena como dosímetro termoluminiscente para dosis terapéuticasarticleinfo:eu-repo/semantics/articlepublishedVersioninfo:eu-repo/semantics/publishedVersionArtículohttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1SandThermoluminescenceDosimetryArenaTermoluminiscenciaDosimetríaRicaurte, DanielSalcedo, JuanaCogollo, RafaelUniversidad de CórdobaIngeniería y Ciencia6117590ing.cienc.ORIGINAL5.pdf5.pdfTexto completo PDFapplication/pdf292495https://repository.eafit.edu.co/bitstreams/e671710f-9405-4cd6-82fe-a3aec283ff8e/download4a1d05af8cf60a8ae4790a9a4583ff4fMD52articulo.htmlarticulo.htmlTexto completo HTMLtext/html373https://repository.eafit.edu.co/bitstreams/4ef4f20b-4a02-4697-ade9-b1fbb7a9e987/downloada517c5fc9c54ba1a83d13122ba76652dMD53THUMBNAILminaitura-ig_Mesa de trabajo 1.jpgminaitura-ig_Mesa de trabajo 1.jpgimage/jpeg265796https://repository.eafit.edu.co/bitstreams/4fc6f3af-ac54-4635-8139-3a3d93299603/downloadda9b21a5c7e00c7f1127cef8e97035e0MD5110784/14491oai:repository.eafit.edu.co:10784/144912020-03-02 22:27:02.845open.accesshttps://repository.eafit.edu.coRepositorio Institucional Universidad EAFITrepositorio@eafit.edu.co
dc.title.eng.fl_str_mv Sand as thermoluminescent dosimeter to therapeutic doses
dc.title.spa.fl_str_mv Arena como dosímetro termoluminiscente para dosis terapéuticas
title Sand as thermoluminescent dosimeter to therapeutic doses
spellingShingle Sand as thermoluminescent dosimeter to therapeutic doses
Sand
Thermoluminescence
Dosimetry
Arena
Termoluminiscencia
Dosimetría
title_short Sand as thermoluminescent dosimeter to therapeutic doses
title_full Sand as thermoluminescent dosimeter to therapeutic doses
title_fullStr Sand as thermoluminescent dosimeter to therapeutic doses
title_full_unstemmed Sand as thermoluminescent dosimeter to therapeutic doses
title_sort Sand as thermoluminescent dosimeter to therapeutic doses
dc.creator.fl_str_mv Ricaurte, Daniel
Salcedo, Juana
Cogollo, Rafael
dc.contributor.author.spa.fl_str_mv Ricaurte, Daniel
Salcedo, Juana
Cogollo, Rafael
dc.contributor.affiliation.spa.fl_str_mv Universidad de Córdoba
dc.subject.keyword.eng.fl_str_mv Sand
Thermoluminescence
Dosimetry
topic Sand
Thermoluminescence
Dosimetry
Arena
Termoluminiscencia
Dosimetría
dc.subject.keyword.spa.fl_str_mv Arena
Termoluminiscencia
Dosimetría
description This work describes the thermoluminescent characteristics of sand from Coveñas beaches for use as a dosimeter in therapeutic doses. Selected samples, heat treated at 400 ° C for one hour, were irradiated at different doses using a 60Co Theratron 780C unit in air at room temperature. The reading was done on a Harshaw TLD 4500. The main dosimetric properties of the material (brightness curve, response reproducibility, reuse, linearity and thermal decay) have been studied in detail. The brightness curve of the sand samples has a TL peak around 145 ° C. The results show that the material has a linear response with the dose from 50 cGy to 1000 cGy. The sand samples studied can be used as thermoluminescent dosimeters for applications in different areas. The importance of this work is that sand is a natural substance available in large quantities, has low cost and can be used in clinical physics to evaluate the dose received by the patient during medical treatment.
publishDate 2010
dc.date.issued.none.fl_str_mv 2010-06-01
dc.date.available.none.fl_str_mv 2019-11-22T19:01:25Z
dc.date.accessioned.none.fl_str_mv 2019-11-22T19:01:25Z
dc.date.none.fl_str_mv 2010-06-01
dc.type.eng.fl_str_mv article
info:eu-repo/semantics/article
publishedVersion
info:eu-repo/semantics/publishedVersion
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_6501
http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.local.spa.fl_str_mv Artículo
status_str publishedVersion
dc.identifier.issn.none.fl_str_mv 2256-4314
1794-9165
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/10784/14491
identifier_str_mv 2256-4314
1794-9165
url http://hdl.handle.net/10784/14491
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.isversionof.none.fl_str_mv http://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/247
dc.relation.uri.none.fl_str_mv http://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/247
dc.rights.eng.fl_str_mv Copyright (c) 2010 Daniel Ricaurte, Juana Salcedo, Rafael Cogollo
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.local.spa.fl_str_mv Acceso abierto
rights_invalid_str_mv Copyright (c) 2010 Daniel Ricaurte, Juana Salcedo, Rafael Cogollo
Acceso abierto
http://purl.org/coar/access_right/c_abf2
dc.format.none.fl_str_mv application/pdf
dc.coverage.spatial.eng.fl_str_mv Medellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degrees
dc.publisher.spa.fl_str_mv Universidad EAFIT
dc.source.none.fl_str_mv instname:Universidad EAFIT
reponame:Repositorio Institucional Universidad EAFIT
dc.source.spa.fl_str_mv Ingeniería y Ciencia; Vol 6, No 11 (2010)
instname_str Universidad EAFIT
institution Universidad EAFIT
reponame_str Repositorio Institucional Universidad EAFIT
collection Repositorio Institucional Universidad EAFIT
bitstream.url.fl_str_mv https://repository.eafit.edu.co/bitstreams/e671710f-9405-4cd6-82fe-a3aec283ff8e/download
https://repository.eafit.edu.co/bitstreams/4ef4f20b-4a02-4697-ade9-b1fbb7a9e987/download
https://repository.eafit.edu.co/bitstreams/4fc6f3af-ac54-4635-8139-3a3d93299603/download
bitstream.checksum.fl_str_mv 4a1d05af8cf60a8ae4790a9a4583ff4f
a517c5fc9c54ba1a83d13122ba76652d
da9b21a5c7e00c7f1127cef8e97035e0
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad EAFIT
repository.mail.fl_str_mv repositorio@eafit.edu.co
_version_ 1814110108955705344