Implementación de estrategias de control avanzado basadas en MPC para tomar decisiones sobre el uso eficiente de la energía fotovoltaica en la Universidad EIA.

85 páginas

Autores:
Stave Guzmán, Edgar Felipe
Liñán Álvarez, Juan Felipe
Tipo de recurso:
Fecha de publicación:
2022
Institución:
Universidad EIA .
Repositorio:
Repositorio EIA .
Idioma:
spa
OAI Identifier:
oai:repository.eia.edu.co:11190/5368
Acceso en línea:
https://repository.eia.edu.co/handle/11190/5368
Palabra clave:
MPC
MPPT
PV system
PPA
Simulink
Boost converter
Rights
openAccess
License
Derechos Reservados - Universidad EIA, 2022
id REIA2_e090a278e90e12b01e8c5b7622e04574
oai_identifier_str oai:repository.eia.edu.co:11190/5368
network_acronym_str REIA2
network_name_str Repositorio EIA .
repository_id_str
dc.title.spa.fl_str_mv Implementación de estrategias de control avanzado basadas en MPC para tomar decisiones sobre el uso eficiente de la energía fotovoltaica en la Universidad EIA.
title Implementación de estrategias de control avanzado basadas en MPC para tomar decisiones sobre el uso eficiente de la energía fotovoltaica en la Universidad EIA.
spellingShingle Implementación de estrategias de control avanzado basadas en MPC para tomar decisiones sobre el uso eficiente de la energía fotovoltaica en la Universidad EIA.
MPC
MPPT
PV system
PPA
Simulink
Boost converter
title_short Implementación de estrategias de control avanzado basadas en MPC para tomar decisiones sobre el uso eficiente de la energía fotovoltaica en la Universidad EIA.
title_full Implementación de estrategias de control avanzado basadas en MPC para tomar decisiones sobre el uso eficiente de la energía fotovoltaica en la Universidad EIA.
title_fullStr Implementación de estrategias de control avanzado basadas en MPC para tomar decisiones sobre el uso eficiente de la energía fotovoltaica en la Universidad EIA.
title_full_unstemmed Implementación de estrategias de control avanzado basadas en MPC para tomar decisiones sobre el uso eficiente de la energía fotovoltaica en la Universidad EIA.
title_sort Implementación de estrategias de control avanzado basadas en MPC para tomar decisiones sobre el uso eficiente de la energía fotovoltaica en la Universidad EIA.
dc.creator.fl_str_mv Stave Guzmán, Edgar Felipe
Liñán Álvarez, Juan Felipe
dc.contributor.advisor.none.fl_str_mv Giraldo Vásquez, Mario Alejandro
dc.contributor.author.none.fl_str_mv Stave Guzmán, Edgar Felipe
Liñán Álvarez, Juan Felipe
dc.subject.proposal.spa.fl_str_mv MPC
MPPT
PV system
PPA
Simulink
Boost converter
topic MPC
MPPT
PV system
PPA
Simulink
Boost converter
description 85 páginas
publishDate 2022
dc.date.accessioned.none.fl_str_mv 2022-07-19T15:04:13Z
dc.date.available.none.fl_str_mv 2022-07-19T15:04:13Z
dc.date.issued.none.fl_str_mv 2022
dc.type.spa.fl_str_mv Trabajo de grado - Pregrado
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_7a1f
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/bachelorThesis
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv https://purl.org/redcol/resource_type/TP
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
status_str publishedVersion
dc.identifier.uri.none.fl_str_mv https://repository.eia.edu.co/handle/11190/5368
url https://repository.eia.edu.co/handle/11190/5368
dc.language.iso.spa.fl_str_mv spa
language spa
dc.rights.spa.fl_str_mv Derechos Reservados - Universidad EIA, 2022
dc.rights.uri.spa.fl_str_mv https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.creativecommons.spa.fl_str_mv Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Derechos Reservados - Universidad EIA, 2022
https://creativecommons.org/licenses/by-nc-nd/4.0/
Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad EIA
dc.publisher.program.spa.fl_str_mv Ingeniería Mecatrónica
dc.publisher.faculty.spa.fl_str_mv Escuela de Ingeniería y Ciencias Básicas
dc.publisher.place.spa.fl_str_mv Envigado (Antioquia, Colombia)
institution Universidad EIA .
bitstream.url.fl_str_mv https://repository.eia.edu.co/bitstreams/82a24ead-d3d8-4168-afa5-1c01f8f1fffb/download
https://repository.eia.edu.co/bitstreams/22caaa65-32fc-431b-9132-efac2c4c233f/download
https://repository.eia.edu.co/bitstreams/a38cf8da-c5d0-49c5-9c05-41ae641fab02/download
https://repository.eia.edu.co/bitstreams/305fdd24-ea09-4f0e-bec6-1f02e104f441/download
bitstream.checksum.fl_str_mv c0b32d6689fe9f7bcc778c2700905ee0
fee37728f2b5e1d97bf811b8df5a0f20
292d9fbbdb18ecee1fa5ea431f9787ae
da9276a8e06ed571bb7fc7c7186cd8fe
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad EIA
repository.mail.fl_str_mv bdigital@metabiblioteca.com
_version_ 1814100923149975552
spelling Giraldo Vásquez, Mario Alejandro437310aa557a0fadc2c6535583c25d74600Stave Guzmán, Edgar Felipe9cca7c7fee58c82dacc5c38bfa33065dLiñán Álvarez, Juan Felipef7bf460c33eb784bdba24bca0edc9a072022-07-19T15:04:13Z2022-07-19T15:04:13Z2022https://repository.eia.edu.co/handle/11190/536885 páginasRESUMEN: En este trabajo de grado se proponen dos estrategias de control predictivo basado en modelo o Model Predictive Control (MPC) para evaluar el comportamiento de la microrred instalada en la EIA para diferentes escenarios de cargas resistivas, agregando un índice de evaluación del consumo de energía como criterio de gestión energética. El objetivo de control del MPC es manipular el convertidor elevador de voltaje para la implementación de un seguimiento del punto de máxima potencia «Maximum Power Point Tracking» (MPPT). En términos generales, el MPPT es el encargado de permitir que el arreglo fotovoltaico entregue a la carga su máxima potencia ante los diferentes cambios del entorno. En una conexión del sistema fotovoltaico fuera de la red «off grid», el MPPT es la interfaz entre el módulo solar, el banco de almacenamiento de energía y el inversor. En este sentido, se proponen dos estrategias para el seguimiento de máxima potencia: la primera, conocida en la literatura como Perturbar y Observar (P&O), y la segunda, una técnica basada en control predictivo, que en su respectiva sección se presentará la comparación en desempeño de ambas. Las estrategias de control se implementan en un modelo detallado de la microrred instalada en la Universidad EIA, sede Palmas, el cual fue elaborado en Simulink. Este sistema modelado se probó en condiciones ideales contante (STC) y en condiciones variables reales de irradiancia, en ambos casos la simulación de los paneles en Simulink se comparó con la generación real, lo cual arrojó buenos resultados, demostrando así, que se tiene un comportamiento similar a los paneles instalados en la EIA.ABSTRACT: In this degree work, two predictive control strategies based on a model or Model Predictive Control (MPC) are proposed to evaluate the behavior of the microgrid installed at EIA for different scenarios of resistive loads, adding an energy consumption evaluation index as energy management criteria. The control objective of the MPC is to manipulate the boost converter to implement Maximum Power Point Tracking (MPPT). In general terms, the MPPT oversees allowing the photovoltaic array to deliver its maximum power to the load in the face of different changes in the environment. In an off grid photovoltaic system connection, the MPPT is the interface between the solar module, the energy storage bank and the inverter. In this sense, two strategies are proposed for maximum power monitoring: the first, known in the literature as Perturb and Observe (P&O), and the second, a technique based on predictive control, which in its respective section will present the comparison in performance of both. The control strategies are implemented in a detailed model of the microgrid installed at the EIA University, Palmas headquarters, which was elaborated in Simulink. This modeled system was tested in ideal constant conditions (STC) and in real variable conditions of irradiance, in both cases the simulation of the panels in Simulink was compared with the real generation, which yielded good results, thus demonstrating that it has a similar behavior to the panels installed at EIA.PregradoIngeniero(a) Mecatrónico(a)application/pdfspaUniversidad EIAIngeniería MecatrónicaEscuela de Ingeniería y Ciencias BásicasEnvigado (Antioquia, Colombia)Derechos Reservados - Universidad EIA, 2022https://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)http://purl.org/coar/access_right/c_abf2Implementación de estrategias de control avanzado basadas en MPC para tomar decisiones sobre el uso eficiente de la energía fotovoltaica en la Universidad EIA.Trabajo de grado - Pregradoinfo:eu-repo/semantics/bachelorThesisinfo:eu-repo/semantics/publishedVersionTexthttps://purl.org/redcol/resource_type/TPhttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_7a1fMPCMPPTPV systemPPASimulinkBoost converterPublicationORIGINALStaveEdgar_2022_ImplementacionEstrategiasControl.pdfStaveEdgar_2022_ImplementacionEstrategiasControl.pdfTrabajo de gradoapplication/pdf1314706https://repository.eia.edu.co/bitstreams/82a24ead-d3d8-4168-afa5-1c01f8f1fffb/downloadc0b32d6689fe9f7bcc778c2700905ee0MD58TEXTStaveEdgar_2022_ImplementacionEstrategiasControl.pdf.txtStaveEdgar_2022_ImplementacionEstrategiasControl.pdf.txtExtracted texttext/plain122846https://repository.eia.edu.co/bitstreams/22caaa65-32fc-431b-9132-efac2c4c233f/downloadfee37728f2b5e1d97bf811b8df5a0f20MD59THUMBNAILStaveEdgar_2022_ImplementacionEstrategiasControl.pdf.jpgStaveEdgar_2022_ImplementacionEstrategiasControl.pdf.jpgGenerated Thumbnailimage/jpeg8414https://repository.eia.edu.co/bitstreams/a38cf8da-c5d0-49c5-9c05-41ae641fab02/download292d9fbbdb18ecee1fa5ea431f9787aeMD510LICENSElicense.txtlicense.txttext/plain; charset=utf-82515https://repository.eia.edu.co/bitstreams/305fdd24-ea09-4f0e-bec6-1f02e104f441/downloadda9276a8e06ed571bb7fc7c7186cd8feMD5711190/5368oai:repository.eia.edu.co:11190/53682023-07-25 17:23:14.158https://creativecommons.org/licenses/by-nc-nd/4.0/Derechos Reservados - Universidad EIA, 2022open.accesshttps://repository.eia.edu.coRepositorio Institucional Universidad EIAbdigital@metabiblioteca.comICAgICAgICAgICAgICAgICAgICAgICAgPGNlbnRlcj5BVklTTyBERSBQUklWQUNJREFEPC9jZW50ZXI+CgpMYSBFc2N1ZWxhIGRlIEluZ2VuaWVyw61hIGRlIEFudGlvcXVpYSBhIHRyYXbDqXMgZGUgZXN0ZSBhdmlzbywgaW5mb3JtYSBhIGxvcyB0aXR1bGFyZXMgZGUgZGF0b3MgcGVyc29uYWxlcyBxdWUgc2UgZW5jdWVudHJlbiBlbiBzdXMgYmFzZXMgZGUgZGF0b3MgcXVlIGxhcyBwb2zDrXRpY2FzIGRlIHRyYXRhbWllbnRvIGRlIGRhdG9zIHBlcnNvbmFsZXMgbGEgRUlBIHNvbjoKCkFsIHRpdHVsYXIgZGUgbG9zIGRhdG9zIHBlcnNvbmFsZXMgZW4gdHJhdGFtaWVudG8sIHNlIGxlIHJlc3BldGFyw6FuIHN1cyBkZXJlY2hvcyBhIGNvbm9jZXIgw61udGVncmFtZW50ZSB5IGRlIGZvcm1hIGdyYXR1aXRhIHN1cyBkYXRvcyBwZXJzb25hbGVzLCBhc8OtIGNvbW8gYSBhY3R1YWxpemFybG9zIHkgcmVjdGlmaWNhcmxvcyBmcmVudGUgYSBsYSBFSUEgbyBsb3MgZW5jYXJnYWRvcyBkZWwgdHJhdGFtaWVudG8uCgpBbCB0aXR1bGFyIGRlIGxvcyBkYXRvcyBwZXJzb25hbGVzIGVuIHRyYXRhbWllbnRvLCBwb2Ryw6EgY29ub2NlciBlbCB1c28gcXVlIHNlIGxlIGhhIGRhZG8gYSBzdXMgZGF0b3MgcGVyc29uYWxlcywgcHJldmlhIHNvbGljaXR1ZC4KCkVsIHRpdHVsYXIgZGUgbG9zIGRhdG9zIHBlcnNvbmFsZXMgZW4gdHJhdGFtaWVudG8sIHBvZHLDoSBzb2xpY2l0YXIgcHJ1ZWJhIGRlIGxhIGF1dG9yaXphY2nDs24gb3RvcmdhZGEgYSBsYSBFSUEuIHNhbHZvIGN1YW5kbyBleHByZXNhbWVudGUgc2UgZXhjZXB0w7plIGNvbW8gcmVxdWlzaXRvIHBhcmEgZWwgdHJhdGFtaWVudG8sIGRlIGNvbmZvcm1pZGFkIGNvbiBsYSBsZXkuCgpFbCB0aXR1bGFyIGRlIGxvcyBkYXRvcyBwdWVkZSByZXZvY2FyIGxhIGF1dG9yaXphY2nDs24geSBzb2xpY2l0YXIgbGEgc3VwcmVzacOzbiBkZWwgZGF0byBjdWFuZG8gZW4gZWwgdHJhdGFtaWVudG8gbm8gc2UgcmVzcGV0ZW4gbG9zIHByaW5jaXBpb3MsIGRlcmVjaG9zIHkgZ2FyYW50w61hcyBjb25zdGl0dWNpb25hbGVzIHkgbGVnYWxlcy4gTGEgcmV2b2NhdG9yaWEgeSBzdXByZXNpw7NuIHByb2NlZGVyw6EgY3VhbmRvIGxhIFN1cGVyaW50ZW5kZW5jaWEgZGUgSW5kdXN0cmlhIHkgQ29tZXJjaW8gKFNJQykgaGF5YSBkZXRlcm1pbmFkbyBxdWUgZW4gZWwgdHJhdGFtaWVudG8sIGxhIEVTQ1VFTEEgREUgSU5HRU5JRVLDjUEgREUgQU5USU9RVUlBIGhhIGluY3VycmlkbyBlbiBjb25kdWN0YXMgY29udHJhcmlhcyBhIGVzdGEgTGV5IHkgYSBsYSBDb25zdGl0dWNpw7NuIFBvbMOtdGljYS4KClBhcmEgZWZlY3RvcyBkZSBlamVyY2VyIHN1cyBkZXJlY2hvcyBkZSBjb25vY2VyLCBhY3R1YWxpemFyLCByZWN0aWZpY2FyIHkgc3VwcmltaXIgaW5mb3JtYWNpw7NuLCByZXZvY2FyIGxhIGF1dG9yaXphY2nDs24sIGVudHJlIG90cm9zOyBlbCB0aXR1bGFyIGRlIGxvcyBkYXRvcyBwb2Ryw6EgYWN1ZGlyIGEgbGEgRVNDVUVMQSBERSBJTkdFTklFUsONQSBERSBBTlRJT1FVSUEsIGNvbW8gcmVzcG9uc2FibGUgZGVsIHRyYXRhbWllbnRvIGRlIGRhdG9zIGFsIMOhcmVhIGRlIGNvbXVuaWNhY2lvbmVzLCBtZWRpYW50ZSBjb3JyZW8gZWxlY3Ryw7NuaWNvIGEgd2VibWFzdGVyQGVpYS5lZHUuY28gLgoKRW4gY2FzbyBkZSBpbmZyYWNjaW9uZXMgYSBsYSBsZXkgMTU4MSBkZSAyMDEyLCBlbCB0aXR1bGFyIGRlIGxvcyBkYXRvcyBwb2Ryw6EgcHJlc2VudGFyIHF1ZWphIGFudGUgbGEgU3VwZXJpbnRlbmRlbmNpYSBkZSBJbmR1c3RyaWEgeSBDb21lcmNpbyAoU0lDKS4KCkVsIHRpdHVsYXIgc2Vyw6EgaW5mb3JtYWRvIGFjZXJjYSBkZSBsYSBubyBvYmxpZ2F0b3JpZWRhZCBkZSBsYXMgcmVzcHVlc3RhcyBhIGxhcyBwcmVndW50YXMgcXVlIGxlIHNlYW4gaGVjaGFzLCBjdWFuZG8gw6lzdGFzIHZlcnNlbiBzb2JyZSBkYXRvcyBzZW5zaWJsZXMsIHRhbGVzIGNvbW8gb3JpZ2VuIHJhY2lhbCBvIMOpdG5pY28sIG9yaWVudGFjacOzbiBwb2zDrXRpY2EsIGNvbnZpY2Npb25lcyByZWxpZ2lvc2FzICwgcGVydGVuZW5jaWEgYSBzaW5kaWNhdG9zLCBvcmdhbml6YWNpb25lcyBzb2NpYWxlcyBkZSBkZXJlY2hvcyBodW1hbm9zLCBkYXRvcyByZWxhdGl2b3MgYSBsYSBzYWx1ZCwgYSBsYSB2aWRhIHNleHVhbCB5IGRhdG9zIGJpb23DqXRyaWNvcyBvIHNvYnJlIGxvcyBkYXRvcyBkZSBsb3MgbmnDsW9zLCBuacOxYXMgeSBhZG9sZXNjZW50ZXMuCgpFbCB0aXR1bGFyIHBvZHLDoSBjb25vY2VyIG51ZXN0cmEgcG9sw610aWNhIGRlIHRyYXRhbWllbnRvLCBsb3MgZGF0b3Mgc3VzdGFuY2lhbGVzIHF1ZSBzZSBsbGVndWVuIGEgcHJvZHVjaXIgZW4gZWwgcHJlc2VudGUgYXZpc28gbyBlbiBsYXMgcG9sw610aWNhcyBkZSB0cmF0YW1pZW50bywgc2Vyw6FuIHB1YmxpY2FkYXMgZW4gbnVlc3RybyBzaXRpbyB3ZWIsIG1lZGlvIGVsZWN0csOzbmljbyBoYWJpdHVhbCBkZSBjb250YWN0byBjb24gbG9zIHRpdHVsYXJlcy4KCg==