Adaptive maximum power point tracking algorithm for multi-variable applications in photovoltaic arrays (Algoritmo adaptativo para seguimiento del punto de máxima potencia en aplicaciones multi-variables de campos fotovoltaicos)

Abstract: Classical algorithms for multi-variable photovoltaic systems use fixed-size perturbations, which does not optimize the produced power in both steady-state and transient conditions. Therefore, an adaptive maximum power point tracking algorithm for photovoltaic systems is proposed in this pa...

Full description

Autores:
Saavedra Montes, Andrés Julián
Ramos Paja, Carlos Andrés
Trejos Grisales, Luz Adriana
Tipo de recurso:
Article of journal
Fecha de publicación:
2014
Institución:
Universidad EIA .
Repositorio:
Repositorio EIA .
Idioma:
spa
OAI Identifier:
oai:repository.eia.edu.co:11190/4867
Acceso en línea:
https://repository.eia.edu.co/handle/11190/4867
https://revistas.eia.edu.co/index.php/reveia/article/view/530
Palabra clave:
keywords
Photovoltaic Generation
Adaptive Algorithm
Maximum Power Point
Efficiency. Palabras clav eS
generación fotovoltaica
algoritmo adaptativo
punto de máxima potencia y eficiencia.
Rights
openAccess
License
Revista EIA - 2014
id REIA2_be5ce71741e95a7c110ad88ff82aed66
oai_identifier_str oai:repository.eia.edu.co:11190/4867
network_acronym_str REIA2
network_name_str Repositorio EIA .
repository_id_str
dc.title.spa.fl_str_mv Adaptive maximum power point tracking algorithm for multi-variable applications in photovoltaic arrays (Algoritmo adaptativo para seguimiento del punto de máxima potencia en aplicaciones multi-variables de campos fotovoltaicos)
dc.title.translated.eng.fl_str_mv Adaptive maximum power point tracking algorithm for multi-variable applications in photovoltaic arrays (Algoritmo adaptativo para seguimiento del punto de máxima potencia en aplicaciones multi-variables de campos fotovoltaicos)
title Adaptive maximum power point tracking algorithm for multi-variable applications in photovoltaic arrays (Algoritmo adaptativo para seguimiento del punto de máxima potencia en aplicaciones multi-variables de campos fotovoltaicos)
spellingShingle Adaptive maximum power point tracking algorithm for multi-variable applications in photovoltaic arrays (Algoritmo adaptativo para seguimiento del punto de máxima potencia en aplicaciones multi-variables de campos fotovoltaicos)
keywords
Photovoltaic Generation
Adaptive Algorithm
Maximum Power Point
Efficiency. Palabras clav eS
generación fotovoltaica
algoritmo adaptativo
punto de máxima potencia y eficiencia.
title_short Adaptive maximum power point tracking algorithm for multi-variable applications in photovoltaic arrays (Algoritmo adaptativo para seguimiento del punto de máxima potencia en aplicaciones multi-variables de campos fotovoltaicos)
title_full Adaptive maximum power point tracking algorithm for multi-variable applications in photovoltaic arrays (Algoritmo adaptativo para seguimiento del punto de máxima potencia en aplicaciones multi-variables de campos fotovoltaicos)
title_fullStr Adaptive maximum power point tracking algorithm for multi-variable applications in photovoltaic arrays (Algoritmo adaptativo para seguimiento del punto de máxima potencia en aplicaciones multi-variables de campos fotovoltaicos)
title_full_unstemmed Adaptive maximum power point tracking algorithm for multi-variable applications in photovoltaic arrays (Algoritmo adaptativo para seguimiento del punto de máxima potencia en aplicaciones multi-variables de campos fotovoltaicos)
title_sort Adaptive maximum power point tracking algorithm for multi-variable applications in photovoltaic arrays (Algoritmo adaptativo para seguimiento del punto de máxima potencia en aplicaciones multi-variables de campos fotovoltaicos)
dc.creator.fl_str_mv Saavedra Montes, Andrés Julián
Ramos Paja, Carlos Andrés
Trejos Grisales, Luz Adriana
dc.contributor.author.spa.fl_str_mv Saavedra Montes, Andrés Julián
Ramos Paja, Carlos Andrés
Trejos Grisales, Luz Adriana
dc.subject.spa.fl_str_mv keywords
Photovoltaic Generation
Adaptive Algorithm
Maximum Power Point
Efficiency. Palabras clav eS
generación fotovoltaica
algoritmo adaptativo
punto de máxima potencia y eficiencia.
topic keywords
Photovoltaic Generation
Adaptive Algorithm
Maximum Power Point
Efficiency. Palabras clav eS
generación fotovoltaica
algoritmo adaptativo
punto de máxima potencia y eficiencia.
description Abstract: Classical algorithms for multi-variable photovoltaic systems use fixed-size perturbations, which does not optimize the produced power in both steady-state and transient conditions. Therefore, an adaptive maximum power point tracking algorithm for photovoltaic systems is proposed in this paper to improve the power generation in both transient and steady-state conditions. The proposed algorithm only uses a single pair of current/voltage sensors to reach the global maximum available power, which contrast with the high number of sensors required by others distributed maximum power point tracking solutions. The algorithm recognizes the voltage pattern exhibited by PV system in both steady-state and transient conditions to adapt the size perturbations accordingly: in steady-state conditions reduces the perturbation size to minimize the power loses, while in transient conditions increases the perturbation size to speed-up the tracking of the new operating point. Finally, the adaptive multi-variable perturb and observe algorithm is validated by means of simulation using detailed models.Resumen: Los algoritmos clásicos para sistemas fotovoltaicos multi-variables usan perturbaciones con amplitud fija, lo cual no optimiza la potencia producida en condiciones estacionarias y transitorias. Por tanto, en este artículo se propone un algoritmo adaptativo para el seguimiento del punto de máxima potencia, el cual incrementa la potencia generada en condiciones estacionarias y transitorias. El algoritmo requiere un único par de sensores de corriente/voltaje para alcanzar el punto de potencia máxima global, en contraste con el alto número de sensores requeridos por otras soluciones distribuidas del seguimiento del punto de máxima potencia. El algoritmo reconoce el patrón de voltaje descrito por el sistema fotovoltaico en condiciones estacionarias y transitorias para adaptar el tamaño de las perturbaciones: es condiciones estacionarias reduce el tamaño de las perturbaciones para minimizar las pérdidas de potencia, mientras que en condiciones transitorias incrementa el tamaño de las perturbaciones para acelerar el seguimiento del nuevo punto de operación. Finalmente, el algoritmo es validado a través de simulación utilizando un modelo matemático detallado de un sistema fotovoltaico.Sumário: Os algorítmos clássicos para sistemas fotovoltaicos multi-variáveis usam perturbações com amplitude fixa, o qual não otimiza a potência produzida em condições estacionárias e transitórias. Por tanto, em este artigo propõe-se um algorítmo adaptativo para o rastreamento do ponto de máxima potência, o qual incrementa a potência gerada em condições estacionárias e transitórias. O algorítmo requer um único par de sensores de corrente/voltaje para atingir o ponto de potência máxima global, em contraste com o alto número de sensores requeridos por outras soluções distribuídas do rastreamento do ponto de máxima potência. O algorítmo reconhece o padrão de voltaje descrito pelo sistema fotovoltaico em condições estacionárias e transitórias para adaptar o tamanho das perturbações: é condições estacionárias reduz o tamanho das perturbações para minimizar as perdas de potência, enquanto em condições transitórias incrementa o tamanho das perturbações para acelerar o rastreamento do novo ponto de operação. Finalmente, o algorítmo é validado através de simulação utilizando um modelo matemático detalhado de um sistema fotovoltaico.
publishDate 2014
dc.date.accessioned.none.fl_str_mv 2014-01-29 00:00:00
2022-06-17T20:17:58Z
dc.date.available.none.fl_str_mv 2014-01-29 00:00:00
2022-06-17T20:17:58Z
dc.date.issued.none.fl_str_mv 2014-01-29
dc.type.spa.fl_str_mv Artículo de revista
dc.type.eng.fl_str_mv Journal article
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
http://purl.org/coar/resource_type/c_6501
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ARTREF
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.issn.none.fl_str_mv 1794-1237
dc.identifier.uri.none.fl_str_mv https://repository.eia.edu.co/handle/11190/4867
dc.identifier.eissn.none.fl_str_mv 2463-0950
dc.identifier.url.none.fl_str_mv https://revistas.eia.edu.co/index.php/reveia/article/view/530
identifier_str_mv 1794-1237
2463-0950
url https://repository.eia.edu.co/handle/11190/4867
https://revistas.eia.edu.co/index.php/reveia/article/view/530
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.bitstream.none.fl_str_mv https://revistas.eia.edu.co/index.php/reveia/article/download/530/513
dc.relation.citationedition.spa.fl_str_mv Núm. 20 , Año 2013
dc.relation.citationendpage.none.fl_str_mv 206
dc.relation.citationissue.spa.fl_str_mv 20
dc.relation.citationstartpage.none.fl_str_mv 193
dc.relation.citationvolume.spa.fl_str_mv 10
dc.relation.ispartofjournal.spa.fl_str_mv Revista EIA
dc.rights.spa.fl_str_mv Revista EIA - 2014
dc.rights.uri.spa.fl_str_mv https://creativecommons.org/licenses/by-nc-nd/4.0
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Revista EIA - 2014
https://creativecommons.org/licenses/by-nc-nd/4.0
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Fondo Editorial EIA - Universidad EIA
dc.source.spa.fl_str_mv https://revistas.eia.edu.co/index.php/reveia/article/view/530
institution Universidad EIA .
bitstream.url.fl_str_mv https://repository.eia.edu.co/bitstreams/d4565d13-8bec-4e7f-b983-bf72ce3dad05/download
bitstream.checksum.fl_str_mv fd467824b9691669160f5ace76928365
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositorio Institucional Universidad EIA
repository.mail.fl_str_mv bdigital@metabiblioteca.com
_version_ 1814100925489348608
spelling Saavedra Montes, Andrés Julián857424d97ad13057c0ea114fdcdc9561Ramos Paja, Carlos Andrés3ed6a4c78cd76ad2ab03d5e52605399cTrejos Grisales, Luz Adriana4634e7f4d8467e4f613f7378cebe4dbe3002014-01-29 00:00:002022-06-17T20:17:58Z2014-01-29 00:00:002022-06-17T20:17:58Z2014-01-291794-1237https://repository.eia.edu.co/handle/11190/48672463-0950https://revistas.eia.edu.co/index.php/reveia/article/view/530Abstract: Classical algorithms for multi-variable photovoltaic systems use fixed-size perturbations, which does not optimize the produced power in both steady-state and transient conditions. Therefore, an adaptive maximum power point tracking algorithm for photovoltaic systems is proposed in this paper to improve the power generation in both transient and steady-state conditions. The proposed algorithm only uses a single pair of current/voltage sensors to reach the global maximum available power, which contrast with the high number of sensors required by others distributed maximum power point tracking solutions. The algorithm recognizes the voltage pattern exhibited by PV system in both steady-state and transient conditions to adapt the size perturbations accordingly: in steady-state conditions reduces the perturbation size to minimize the power loses, while in transient conditions increases the perturbation size to speed-up the tracking of the new operating point. Finally, the adaptive multi-variable perturb and observe algorithm is validated by means of simulation using detailed models.Resumen: Los algoritmos clásicos para sistemas fotovoltaicos multi-variables usan perturbaciones con amplitud fija, lo cual no optimiza la potencia producida en condiciones estacionarias y transitorias. Por tanto, en este artículo se propone un algoritmo adaptativo para el seguimiento del punto de máxima potencia, el cual incrementa la potencia generada en condiciones estacionarias y transitorias. El algoritmo requiere un único par de sensores de corriente/voltaje para alcanzar el punto de potencia máxima global, en contraste con el alto número de sensores requeridos por otras soluciones distribuidas del seguimiento del punto de máxima potencia. El algoritmo reconoce el patrón de voltaje descrito por el sistema fotovoltaico en condiciones estacionarias y transitorias para adaptar el tamaño de las perturbaciones: es condiciones estacionarias reduce el tamaño de las perturbaciones para minimizar las pérdidas de potencia, mientras que en condiciones transitorias incrementa el tamaño de las perturbaciones para acelerar el seguimiento del nuevo punto de operación. Finalmente, el algoritmo es validado a través de simulación utilizando un modelo matemático detallado de un sistema fotovoltaico.Sumário: Os algorítmos clássicos para sistemas fotovoltaicos multi-variáveis usam perturbações com amplitude fixa, o qual não otimiza a potência produzida em condições estacionárias e transitórias. Por tanto, em este artigo propõe-se um algorítmo adaptativo para o rastreamento do ponto de máxima potência, o qual incrementa a potência gerada em condições estacionárias e transitórias. O algorítmo requer um único par de sensores de corrente/voltaje para atingir o ponto de potência máxima global, em contraste com o alto número de sensores requeridos por outras soluções distribuídas do rastreamento do ponto de máxima potência. O algorítmo reconhece o padrão de voltaje descrito pelo sistema fotovoltaico em condições estacionárias e transitórias para adaptar o tamanho das perturbações: é condições estacionárias reduz o tamanho das perturbações para minimizar as perdas de potência, enquanto em condições transitórias incrementa o tamanho das perturbações para acelerar o rastreamento do novo ponto de operação. Finalmente, o algorítmo é validado através de simulação utilizando um modelo matemático detalhado de um sistema fotovoltaico.Abstract: Classical algorithms for multi-variable photovoltaic systems use fixed-size perturbations, which does not optimize the produced power in both steady-state and transient conditions. Therefore, an adaptive maximum power point tracking algorithm for photovoltaic systems is proposed in this paper to improve the power generation in both transient and steady-state conditions. The proposed algorithm only uses a single pair of current/voltage sensors to reach the global maximum available power, which contrast with the high number of sensors required by others distributed maximum power point tracking solutions. The algorithm recognizes the voltage pattern exhibited by PV system in both steady-state and transient conditions to adapt the size perturbations accordingly: in steady-state conditions reduces the perturbation size to minimize the power loses, while in transient conditions increases the perturbation size to speed-up the tracking of the new operating point. Finally, the adaptive multi-variable perturb and observe algorithm is validated by means of simulation using detailed models.Resumen: Los algoritmos clásicos para sistemas fotovoltaicos multi-variables usan perturbaciones con amplitud fija, lo cual no optimiza la potencia producida en condiciones estacionarias y transitorias. Por tanto, en este artículo se propone un algoritmo adaptativo para el seguimiento del punto de máxima potencia, el cual incrementa la potencia generada en condiciones estacionarias y transitorias. El algoritmo requiere un único par de sensores de corriente/voltaje para alcanzar el punto de potencia máxima global, en contraste con el alto número de sensores requeridos por otras soluciones distribuidas del seguimiento del punto de máxima potencia. El algoritmo reconoce el patrón de voltaje descrito por el sistema fotovoltaico en condiciones estacionarias y transitorias para adaptar el tamaño de las perturbaciones: es condiciones estacionarias reduce el tamaño de las perturbaciones para minimizar las pérdidas de potencia, mientras que en condiciones transitorias incrementa el tamaño de las perturbaciones para acelerar el seguimiento del nuevo punto de operación. Finalmente, el algoritmo es validado a través de simulación utilizando un modelo matemático detallado de un sistema fotovoltaico.Sumário: Os algorítmos clássicos para sistemas fotovoltaicos multi-variáveis usam perturbações com amplitude fixa, o qual não otimiza a potência produzida em condições estacionárias e transitórias. Por tanto, em este artigo propõe-se um algorítmo adaptativo para o rastreamento do ponto de máxima potência, o qual incrementa a potência gerada em condições estacionárias e transitórias. O algorítmo requer um único par de sensores de corrente/voltaje para atingir o ponto de potência máxima global, em contraste com o alto número de sensores requeridos por outras soluções distribuídas do rastreamento do ponto de máxima potência. O algorítmo reconhece o padrão de voltaje descrito pelo sistema fotovoltaico em condições estacionárias e transitórias para adaptar o tamanho das perturbações: é condições estacionárias reduz o tamanho das perturbações para minimizar as perdas de potência, enquanto em condições transitórias incrementa o tamanho das perturbações para acelerar o rastreamento do novo ponto de operação. Finalmente, o algorítmo é validado através de simulação utilizando um modelo matemático detalhado de um sistema fotovoltaico.application/pdfspaFondo Editorial EIA - Universidad EIARevista EIA - 2014https://creativecommons.org/licenses/by-nc-nd/4.0info:eu-repo/semantics/openAccessEsta obra está bajo una licencia internacional Creative Commons Atribución-NoComercial-SinDerivadas 4.0.http://purl.org/coar/access_right/c_abf2https://revistas.eia.edu.co/index.php/reveia/article/view/530keywordsPhotovoltaic GenerationAdaptive AlgorithmMaximum Power PointEfficiency. Palabras clav eSgeneración fotovoltaicaalgoritmo adaptativopunto de máxima potencia y eficiencia.Adaptive maximum power point tracking algorithm for multi-variable applications in photovoltaic arrays (Algoritmo adaptativo para seguimiento del punto de máxima potencia en aplicaciones multi-variables de campos fotovoltaicos)Adaptive maximum power point tracking algorithm for multi-variable applications in photovoltaic arrays (Algoritmo adaptativo para seguimiento del punto de máxima potencia en aplicaciones multi-variables de campos fotovoltaicos)Artículo de revistaJournal articlehttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionTexthttp://purl.org/redcol/resource_type/ARTREFhttp://purl.org/coar/version/c_970fb48d4fbd8a85https://revistas.eia.edu.co/index.php/reveia/article/download/530/513Núm. 20 , Año 20132062019310Revista EIAPublicationOREORE.xmltext/xml2960https://repository.eia.edu.co/bitstreams/d4565d13-8bec-4e7f-b983-bf72ce3dad05/downloadfd467824b9691669160f5ace76928365MD5111190/4867oai:repository.eia.edu.co:11190/48672023-07-25 17:24:59.796https://creativecommons.org/licenses/by-nc-nd/4.0Revista EIA - 2014metadata.onlyhttps://repository.eia.edu.coRepositorio Institucional Universidad EIAbdigital@metabiblioteca.com