ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY II: IMPLEMENTED DESIGN
A detailed description of the electronic system designed to improve the measurements in an experimental AC electrogravimetry setup is presented. This system is committed to acquire appropriated data for determining the Electrogravimetric Transfer Function (EGTF) and provide information regarding the...
- Autores:
-
Torres, Róbinson
Arnau, Antonio
Perrot, Hubert
Aedo, José Edinson
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2013
- Institución:
- Universidad EIA .
- Repositorio:
- Repositorio EIA .
- Idioma:
- eng
- OAI Identifier:
- oai:repository.eia.edu.co:11190/4671
- Acceso en línea:
- https://repository.eia.edu.co/handle/11190/4671
https://revistas.eia.edu.co/index.php/reveia/article/view/171
- Palabra clave:
- AC electrogravimetry
quartz crystal microbalance
phase locked loops
bandwidthresolution trade-off
coarse and fine tuning. Palabras claves
electrogravimetría AC
microbalanza de cristal de cuarzo
bucles de enganche de fase
compromiso ancho de ban
- Rights
- openAccess
- License
- Revista EIA - 2013
id |
REIA2_84ddd304d6c5e2da6b8c7bcba3b765d8 |
---|---|
oai_identifier_str |
oai:repository.eia.edu.co:11190/4671 |
network_acronym_str |
REIA2 |
network_name_str |
Repositorio EIA . |
repository_id_str |
|
dc.title.spa.fl_str_mv |
ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY II: IMPLEMENTED DESIGN |
dc.title.translated.eng.fl_str_mv |
ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY II: IMPLEMENTED DESIGN |
title |
ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY II: IMPLEMENTED DESIGN |
spellingShingle |
ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY II: IMPLEMENTED DESIGN AC electrogravimetry quartz crystal microbalance phase locked loops bandwidthresolution trade-off coarse and fine tuning. Palabras claves electrogravimetría AC microbalanza de cristal de cuarzo bucles de enganche de fase compromiso ancho de ban |
title_short |
ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY II: IMPLEMENTED DESIGN |
title_full |
ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY II: IMPLEMENTED DESIGN |
title_fullStr |
ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY II: IMPLEMENTED DESIGN |
title_full_unstemmed |
ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY II: IMPLEMENTED DESIGN |
title_sort |
ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY II: IMPLEMENTED DESIGN |
dc.creator.fl_str_mv |
Torres, Róbinson Arnau, Antonio Perrot, Hubert Aedo, José Edinson |
dc.contributor.author.spa.fl_str_mv |
Torres, Róbinson Arnau, Antonio Perrot, Hubert Aedo, José Edinson |
dc.subject.eng.fl_str_mv |
AC electrogravimetry quartz crystal microbalance phase locked loops bandwidthresolution trade-off coarse and fine tuning. Palabras claves electrogravimetría AC microbalanza de cristal de cuarzo bucles de enganche de fase compromiso ancho de ban |
topic |
AC electrogravimetry quartz crystal microbalance phase locked loops bandwidthresolution trade-off coarse and fine tuning. Palabras claves electrogravimetría AC microbalanza de cristal de cuarzo bucles de enganche de fase compromiso ancho de ban |
description |
A detailed description of the electronic system designed to improve the measurements in an experimental AC electrogravimetry setup is presented. This system is committed to acquire appropriated data for determining the Electrogravimetric Transfer Function (EGTF) and provide information regarding the mass transfer in an electrochemical cell in the AC Electrogravimetry Technique, but maintaining a good trade-off between the locking frequency bandwidth and the resolution in the frequency tracking, that is, enlarging the bandwidth of the system to follow signals with frequency as higher as 1 kHz, but maintaining an accurate and continuous tracking of this signal. The enlarged bandwidth allows the study of fast kinetic process in electrochemical applications and the continuous tracking let to achieve a precise measurement with good resolution rather than average frequency records obtained by conventional frequency meters. The system is based on an Analogue-Digital Phase Locked Loop (A-D PLL).Resumen: En este artículo se presenta una descripción detallada del sistema electrónico diseñado para mejorar las medidas en un sistema experimental de electrogravimetría AC. El sistema diseñado se encarga de adquirir los datos adecuados para determinar la función de transferencia electrogravimétrica (EGTF) y proveer información relacionada con la transferencia de masa en una celda electroquímica en la técnica de electrogravimetría AC, pero manteniendo un buen compromiso entre el ancho de banda de enganche y la resolución en el seguimiento de la frecuencia, es decir, el sistema incrementa el ancho de banda para permitir el seguimiento de señales con frecuencias hasta de 1 kHz, pero conservando un exacto y continuo seguimiento de esta señal. El aumento del ancho de banda permite el estudio de procesos con una cinética rápida en aplicaciones electroquímicas y el seguimiento continuo de la señal permite la obtención de medidas precisas con buena resolución en contraste con los datos de frecuencia promediados entregados por los frecuencímetros convencionales. El sistema se basa en un bucle de enganche de fase analógico-digital (A-D PLL). |
publishDate |
2013 |
dc.date.accessioned.none.fl_str_mv |
2013-10-09 00:00:00 2022-06-17T20:15:51Z |
dc.date.available.none.fl_str_mv |
2013-10-09 00:00:00 2022-06-17T20:15:51Z |
dc.date.issued.none.fl_str_mv |
2013-10-09 |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.eng.fl_str_mv |
Journal article |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.coar.eng.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 http://purl.org/coar/resource_type/c_6501 |
dc.type.driver.eng.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.version.eng.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.content.eng.fl_str_mv |
Text |
dc.type.redcol.eng.fl_str_mv |
http://purl.org/redcol/resource_type/ARTREF |
dc.type.coarversion.eng.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.issn.none.fl_str_mv |
1794-1237 |
dc.identifier.uri.none.fl_str_mv |
https://repository.eia.edu.co/handle/11190/4671 |
dc.identifier.eissn.none.fl_str_mv |
2463-0950 |
dc.identifier.url.none.fl_str_mv |
https://revistas.eia.edu.co/index.php/reveia/article/view/171 |
identifier_str_mv |
1794-1237 2463-0950 |
url |
https://repository.eia.edu.co/handle/11190/4671 https://revistas.eia.edu.co/index.php/reveia/article/view/171 |
dc.language.iso.eng.fl_str_mv |
eng |
language |
eng |
dc.relation.bitstream.none.fl_str_mv |
https://revistas.eia.edu.co/index.php/reveia/article/download/171/168 |
dc.relation.citationedition.spa.fl_str_mv |
Núm. 7 , Año 2007 |
dc.relation.citationendpage.none.fl_str_mv |
73 |
dc.relation.citationissue.spa.fl_str_mv |
7 |
dc.relation.citationstartpage.none.fl_str_mv |
63 |
dc.relation.citationvolume.spa.fl_str_mv |
4 |
dc.relation.ispartofjournal.spa.fl_str_mv |
Revista EIA |
dc.rights.eng.fl_str_mv |
Revista EIA - 2013 |
dc.rights.uri.eng.fl_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0 |
dc.rights.accessrights.eng.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.coar.eng.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
rights_invalid_str_mv |
Revista EIA - 2013 https://creativecommons.org/licenses/by-nc-nd/4.0 http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.eng.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Fondo Editorial EIA - Universidad EIA |
dc.source.eng.fl_str_mv |
https://revistas.eia.edu.co/index.php/reveia/article/view/171 |
institution |
Universidad EIA . |
bitstream.url.fl_str_mv |
https://repository.eia.edu.co/bitstreams/a1f2943b-05dd-4d0a-96ed-b3039ccb1129/download |
bitstream.checksum.fl_str_mv |
06ed35f6927ee8887bca3b4e096e32a2 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad EIA |
repository.mail.fl_str_mv |
bdigital@metabiblioteca.com |
_version_ |
1814100906885513216 |
spelling |
Torres, Róbinson6209a2b86f35bcc047413544509b82a3500Arnau, Antonio19618e66600d463f90431de665a6ca39500Perrot, Hubert2683901a2c94c26c445ba5f21f7099b4500Aedo, José Edinsonffa36a54086acc03c03ebceeaf2829a53002013-10-09 00:00:002022-06-17T20:15:51Z2013-10-09 00:00:002022-06-17T20:15:51Z2013-10-091794-1237https://repository.eia.edu.co/handle/11190/46712463-0950https://revistas.eia.edu.co/index.php/reveia/article/view/171A detailed description of the electronic system designed to improve the measurements in an experimental AC electrogravimetry setup is presented. This system is committed to acquire appropriated data for determining the Electrogravimetric Transfer Function (EGTF) and provide information regarding the mass transfer in an electrochemical cell in the AC Electrogravimetry Technique, but maintaining a good trade-off between the locking frequency bandwidth and the resolution in the frequency tracking, that is, enlarging the bandwidth of the system to follow signals with frequency as higher as 1 kHz, but maintaining an accurate and continuous tracking of this signal. The enlarged bandwidth allows the study of fast kinetic process in electrochemical applications and the continuous tracking let to achieve a precise measurement with good resolution rather than average frequency records obtained by conventional frequency meters. The system is based on an Analogue-Digital Phase Locked Loop (A-D PLL).Resumen: En este artículo se presenta una descripción detallada del sistema electrónico diseñado para mejorar las medidas en un sistema experimental de electrogravimetría AC. El sistema diseñado se encarga de adquirir los datos adecuados para determinar la función de transferencia electrogravimétrica (EGTF) y proveer información relacionada con la transferencia de masa en una celda electroquímica en la técnica de electrogravimetría AC, pero manteniendo un buen compromiso entre el ancho de banda de enganche y la resolución en el seguimiento de la frecuencia, es decir, el sistema incrementa el ancho de banda para permitir el seguimiento de señales con frecuencias hasta de 1 kHz, pero conservando un exacto y continuo seguimiento de esta señal. El aumento del ancho de banda permite el estudio de procesos con una cinética rápida en aplicaciones electroquímicas y el seguimiento continuo de la señal permite la obtención de medidas precisas con buena resolución en contraste con los datos de frecuencia promediados entregados por los frecuencímetros convencionales. El sistema se basa en un bucle de enganche de fase analógico-digital (A-D PLL).A detailed description of the electronic system designed to improve the measurements in an experimental AC electrogravimetry setup is presented. This system is committed to acquire appropriated data for determining the Electrogravimetric Transfer Function (EGTF) and provide information regarding the mass transfer in an electrochemical cell in the AC Electrogravimetry Technique, but maintaining a good trade-off between the locking frequency bandwidth and the resolution in the frequency tracking, that is, enlarging the bandwidth of the system to follow signals with frequency as higher as 1 kHz, but maintaining an accurate and continuous tracking of this signal. The enlarged bandwidth allows the study of fast kinetic process in electrochemical applications and the continuous tracking let to achieve a precise measurement with good resolution rather than average frequency records obtained by conventional frequency meters. The system is based on an Analogue-Digital Phase Locked Loop (A-D PLL).Resumen: En este artículo se presenta una descripción detallada del sistema electrónico diseñado para mejorar las medidas en un sistema experimental de electrogravimetría AC. El sistema diseñado se encarga de adquirir los datos adecuados para determinar la función de transferencia electrogravimétrica (EGTF) y proveer información relacionada con la transferencia de masa en una celda electroquímica en la técnica de electrogravimetría AC, pero manteniendo un buen compromiso entre el ancho de banda de enganche y la resolución en el seguimiento de la frecuencia, es decir, el sistema incrementa el ancho de banda para permitir el seguimiento de señales con frecuencias hasta de 1 kHz, pero conservando un exacto y continuo seguimiento de esta señal. El aumento del ancho de banda permite el estudio de procesos con una cinética rápida en aplicaciones electroquímicas y el seguimiento continuo de la señal permite la obtención de medidas precisas con buena resolución en contraste con los datos de frecuencia promediados entregados por los frecuencímetros convencionales. El sistema se basa en un bucle de enganche de fase analógico-digital (A-D PLL).application/pdfengFondo Editorial EIA - Universidad EIARevista EIA - 2013https://creativecommons.org/licenses/by-nc-nd/4.0info:eu-repo/semantics/openAccessEsta obra está bajo una licencia internacional Creative Commons Atribución-NoComercial-SinDerivadas 4.0.http://purl.org/coar/access_right/c_abf2https://revistas.eia.edu.co/index.php/reveia/article/view/171AC electrogravimetryquartz crystal microbalancephase locked loopsbandwidthresolution trade-offcoarse and fine tuning. Palabras claveselectrogravimetría ACmicrobalanza de cristal de cuarzobucles de enganche de fasecompromiso ancho de banELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY II: IMPLEMENTED DESIGNELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY II: IMPLEMENTED DESIGNArtículo de revistaJournal articlehttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionTexthttp://purl.org/redcol/resource_type/ARTREFhttp://purl.org/coar/version/c_970fb48d4fbd8a85https://revistas.eia.edu.co/index.php/reveia/article/download/171/168Núm. 7 , Año 2007737634Revista EIAPublicationOREORE.xmltext/xml2681https://repository.eia.edu.co/bitstreams/a1f2943b-05dd-4d0a-96ed-b3039ccb1129/download06ed35f6927ee8887bca3b4e096e32a2MD5111190/4671oai:repository.eia.edu.co:11190/46712023-07-25 17:12:15.081https://creativecommons.org/licenses/by-nc-nd/4.0Revista EIA - 2013metadata.onlyhttps://repository.eia.edu.coRepositorio Institucional Universidad EIAbdigital@metabiblioteca.com |