Seguimiento a los factores incidentes en la vida útil de transformadores de distribución tipo poste en la ciudad de Barranquilla

Failures in mono-phase transformers mounted in posts, which are installed in distribution power grids in proximity to users, use to be associated to a highest number of reports. The above affects the reliability indicators affecting the maximum annual hours of unavailability as well as affecting the...

Full description

Autores:
Holguin Torres, Yeimi Carolina
Tipo de recurso:
Trabajo de grado de pregrado
Fecha de publicación:
2017
Institución:
Corporación Universidad de la Costa
Repositorio:
REDICUC - Repositorio CUC
Idioma:
spa
OAI Identifier:
oai:repositorio.cuc.edu.co:11323/313
Acceso en línea:
https://hdl.handle.net/11323/313
https://repositorio.cuc.edu.co/
Palabra clave:
Diagnostico
Falla
Transformador
Confiabilidad
Rights
openAccess
License
Atribución – No comercial – Compartir igual
id RCUC2_c04c34eba1d8dc655ca0a4b64bcf3e13
oai_identifier_str oai:repositorio.cuc.edu.co:11323/313
network_acronym_str RCUC2
network_name_str REDICUC - Repositorio CUC
repository_id_str
dc.title.eng.fl_str_mv Seguimiento a los factores incidentes en la vida útil de transformadores de distribución tipo poste en la ciudad de Barranquilla
title Seguimiento a los factores incidentes en la vida útil de transformadores de distribución tipo poste en la ciudad de Barranquilla
spellingShingle Seguimiento a los factores incidentes en la vida útil de transformadores de distribución tipo poste en la ciudad de Barranquilla
Diagnostico
Falla
Transformador
Confiabilidad
title_short Seguimiento a los factores incidentes en la vida útil de transformadores de distribución tipo poste en la ciudad de Barranquilla
title_full Seguimiento a los factores incidentes en la vida útil de transformadores de distribución tipo poste en la ciudad de Barranquilla
title_fullStr Seguimiento a los factores incidentes en la vida útil de transformadores de distribución tipo poste en la ciudad de Barranquilla
title_full_unstemmed Seguimiento a los factores incidentes en la vida útil de transformadores de distribución tipo poste en la ciudad de Barranquilla
title_sort Seguimiento a los factores incidentes en la vida útil de transformadores de distribución tipo poste en la ciudad de Barranquilla
dc.creator.fl_str_mv Holguin Torres, Yeimi Carolina
dc.contributor.advisor.spa.fl_str_mv Silva Ortega, Jorge Iván
dc.contributor.author.spa.fl_str_mv Holguin Torres, Yeimi Carolina
dc.contributor.coasesor.spa.fl_str_mv Ospino Castro, Adalberto
dc.contributor.authorco.spa.fl_str_mv Villacob Pineda, Karen Judith
dc.subject.eng.fl_str_mv Diagnostico
Falla
Transformador
Confiabilidad
topic Diagnostico
Falla
Transformador
Confiabilidad
description Failures in mono-phase transformers mounted in posts, which are installed in distribution power grids in proximity to users, use to be associated to a highest number of reports. The above affects the reliability indicators affecting the maximum annual hours of unavailability as well as affecting the economic and financial forecasts in the utility. The project describe the factors that determine the failures of a single-phase distribution transformers installed in a distribution network post in 13.2 kV level. A follow-up model was developed for the analysis and diagnosis of faults in which is determined the lifetime of the distribution transformers installed in the Colombian Atlantic coast. The information reported in the utility database (ELECTRICARIBE S.A. E.S.P.) was considered in order to characterize transformers. The last allows to corroborate the veracity and reliability of the information collected to select the population sample considered. The results identified that the main causes of failure in mono-phases distribution transformers installed in Barranquilla and under climatic conditions of warm weather with bad environmental pollution correspond to: overload, overvoltage and overcurrent, exposure to humidity, presence of hot spots caused by bad connection during the installation, manufacturing process, and lack of technical knowledge. Also, Time lines are presented to achieve the characterization of these faults. Finally, it is possible to identify that the most critical faults and that affects lifetimes equipment’s are hot spots which according to the statistical analyzes could cause the failure of a transformer in 16 days.
publishDate 2017
dc.date.issued.none.fl_str_mv 2017-10-23
dc.date.accessioned.none.fl_str_mv 2018-11-03T17:16:58Z
dc.date.available.none.fl_str_mv 2018-11-03T17:16:58Z
dc.type.spa.fl_str_mv Trabajo de grado - Pregrado
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_7a1f
dc.type.content.spa.fl_str_mv Text
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/bachelorThesis
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/TP
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/acceptedVersion
format http://purl.org/coar/resource_type/c_7a1f
status_str acceptedVersion
dc.identifier.uri.spa.fl_str_mv https://hdl.handle.net/11323/313
dc.identifier.instname.spa.fl_str_mv Corporación Universidad de la Costa
dc.identifier.reponame.spa.fl_str_mv REDICUC - Repositorio CUC
dc.identifier.repourl.spa.fl_str_mv https://repositorio.cuc.edu.co/
url https://hdl.handle.net/11323/313
https://repositorio.cuc.edu.co/
identifier_str_mv Corporación Universidad de la Costa
REDICUC - Repositorio CUC
dc.language.iso.none.fl_str_mv spa
language spa
dc.rights.spa.fl_str_mv Atribución – No comercial – Compartir igual
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Atribución – No comercial – Compartir igual
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.publisher.program.spa.fl_str_mv Ingeniería Eléctrica
institution Corporación Universidad de la Costa
bitstream.url.fl_str_mv https://repositorio.cuc.edu.co/bitstreams/cdd35097-1770-4161-a47b-8afd57ea26ff/download
https://repositorio.cuc.edu.co/bitstreams/08aa5cd7-b42b-4603-9e46-ff0f7c107ec3/download
https://repositorio.cuc.edu.co/bitstreams/e123169a-b4ba-47cc-8b98-91f597e20309/download
https://repositorio.cuc.edu.co/bitstreams/932b45fb-0701-41cd-a165-6708c1b1a550/download
bitstream.checksum.fl_str_mv 67336a9bf2983e0593e67428cb6f9fd8
8a4605be74aa9ea9d79846c1fba20a33
4e6b2cf047ce6a0bb16d03ff9074019d
85876935d6fe664b6b29cc5a7c6ff2c1
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio de la Universidad de la Costa CUC
repository.mail.fl_str_mv repdigital@cuc.edu.co
_version_ 1811760737637367808
spelling Silva Ortega, Jorge IvánHolguin Torres, Yeimi CarolinaOspino Castro, AdalbertoVillacob Pineda, Karen Judith2018-11-03T17:16:58Z2018-11-03T17:16:58Z2017-10-23https://hdl.handle.net/11323/313Corporación Universidad de la CostaREDICUC - Repositorio CUChttps://repositorio.cuc.edu.co/Failures in mono-phase transformers mounted in posts, which are installed in distribution power grids in proximity to users, use to be associated to a highest number of reports. The above affects the reliability indicators affecting the maximum annual hours of unavailability as well as affecting the economic and financial forecasts in the utility. The project describe the factors that determine the failures of a single-phase distribution transformers installed in a distribution network post in 13.2 kV level. A follow-up model was developed for the analysis and diagnosis of faults in which is determined the lifetime of the distribution transformers installed in the Colombian Atlantic coast. The information reported in the utility database (ELECTRICARIBE S.A. E.S.P.) was considered in order to characterize transformers. The last allows to corroborate the veracity and reliability of the information collected to select the population sample considered. The results identified that the main causes of failure in mono-phases distribution transformers installed in Barranquilla and under climatic conditions of warm weather with bad environmental pollution correspond to: overload, overvoltage and overcurrent, exposure to humidity, presence of hot spots caused by bad connection during the installation, manufacturing process, and lack of technical knowledge. Also, Time lines are presented to achieve the characterization of these faults. Finally, it is possible to identify that the most critical faults and that affects lifetimes equipment’s are hot spots which according to the statistical analyzes could cause the failure of a transformer in 16 days.Las salidas de operación de transformadores monofásicos tipo poste instalados en redes de distribución en proximidad a usuarios finales suelen ser los activos de conexión con mayor número de reportes por fallas. Lo anterior compromente los indicadores de confiabilidad incidiendo en las horas máximas anuales de indisponibilidad al igual que incide en los pronosticos económicos y financieros del operador de red. El proyecto de investigación busca conocer los factores que determinan las fallas de los transformadores monofásicos tipo poste instalados en una red de distribución de 13.2 kV. Se desarrolló un modelo de seguimiento para el analisis y diagnosticos de las fallas en las cuales se determinan la vida util de los transformadores de distribución en la costa atlantica colombiana. Se consideró la información reportada por la base de datos del operador de red (ELECTRICARIBE S.A. E.S.P.) para lograr la caracterización de falla de los transformadores de distribución. Lo anterior permite corroborar la veracidad y confiabiidad de la información recopilada para seleccionar la muestra poblacional de transformadores seleccionada. Los resultados identificaron que las principales causas de falla en tranformadores monofasicos de distribución tipo poste instalados en la ciudad de Barranquilla y bajo condiciones climatologicas de clima calido con una mala contaminación ambiental corresponde a: sobrecarga, sobretensión y sobrecorriente, exposición a humedad, presencia de Puntos Calientes causados por mala conexión durante el proceso de instalación y fabricación y el desconocimiento técnico. se presentan líneas de tiempo para lograr la caracterización de estas fallas. Finalmente, se logra identificar que las fallas mas criticas y que deterioran la vida util del equipo es la falla por punto caliente la cual de acuerdo a los analisis estadisticos realizados podría causar la falla de un transformador en 16 días conectados a las redes de distribuciónHolguin Torres, Yeimi Carolina-1f73fb54-55f0-4d04-994d-02cc562cb0ac-600spaAtribución – No comercial – Compartir igualinfo:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2DiagnosticoFallaTransformadorConfiabilidadSeguimiento a los factores incidentes en la vida útil de transformadores de distribución tipo poste en la ciudad de BarranquillaTrabajo de grado - Pregradohttp://purl.org/coar/resource_type/c_7a1fTextinfo:eu-repo/semantics/bachelorThesishttp://purl.org/redcol/resource_type/TPinfo:eu-repo/semantics/acceptedVersionIngeniería EléctricaPublicationORIGINAL45535276-57308604.pdf45535276-57308604.pdfapplication/pdf1477572https://repositorio.cuc.edu.co/bitstreams/cdd35097-1770-4161-a47b-8afd57ea26ff/download67336a9bf2983e0593e67428cb6f9fd8MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.cuc.edu.co/bitstreams/08aa5cd7-b42b-4603-9e46-ff0f7c107ec3/download8a4605be74aa9ea9d79846c1fba20a33MD53THUMBNAIL45535276-57308604.pdf.jpg45535276-57308604.pdf.jpgimage/jpeg24790https://repositorio.cuc.edu.co/bitstreams/e123169a-b4ba-47cc-8b98-91f597e20309/download4e6b2cf047ce6a0bb16d03ff9074019dMD55TEXT45535276-57308604.pdf.txt45535276-57308604.pdf.txttext/plain129874https://repositorio.cuc.edu.co/bitstreams/932b45fb-0701-41cd-a165-6708c1b1a550/download85876935d6fe664b6b29cc5a7c6ff2c1MD5611323/313oai:repositorio.cuc.edu.co:11323/3132024-09-17 10:53:42.858open.accesshttps://repositorio.cuc.edu.coRepositorio de la Universidad de la Costa CUCrepdigital@cuc.edu.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