Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring

Different methods have been developed to estimate the energy efficiency of induction motors. The accuracy of these methods vary with the load factor, the unbalanced voltage (UV) and harmonics. The feasibility of these methods for efficiency estimation in real-time were theoretically and experimental...

Full description

Autores:
Sousa Santos, Vladimir
Cabello Eras, Juan Jose
Sagastume Gutierrez, Alexis
Cabello Ulloa, Mario Javier
Tipo de recurso:
Article of journal
Fecha de publicación:
2018
Institución:
Corporación Universidad de la Costa
Repositorio:
REDICUC - Repositorio CUC
Idioma:
eng
OAI Identifier:
oai:repositorio.cuc.edu.co:11323/1988
Acceso en línea:
https://hdl.handle.net/11323/1988
https://repositorio.cuc.edu.co/
Palabra clave:
Energy efficiency
Harmonics
Induction motors
Real-time monitoring
Voltage unbalance
Rights
openAccess
License
Atribución – No comercial – Compartir igual
id RCUC2_b4ad9501c7df3822fa92724ccd4109c9
oai_identifier_str oai:repositorio.cuc.edu.co:11323/1988
network_acronym_str RCUC2
network_name_str REDICUC - Repositorio CUC
repository_id_str
dc.title.spa.fl_str_mv Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring
title Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring
spellingShingle Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring
Energy efficiency
Harmonics
Induction motors
Real-time monitoring
Voltage unbalance
title_short Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring
title_full Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring
title_fullStr Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring
title_full_unstemmed Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring
title_sort Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring
dc.creator.fl_str_mv Sousa Santos, Vladimir
Cabello Eras, Juan Jose
Sagastume Gutierrez, Alexis
Cabello Ulloa, Mario Javier
dc.contributor.author.spa.fl_str_mv Sousa Santos, Vladimir
Cabello Eras, Juan Jose
Sagastume Gutierrez, Alexis
Cabello Ulloa, Mario Javier
dc.subject.spa.fl_str_mv Energy efficiency
Harmonics
Induction motors
Real-time monitoring
Voltage unbalance
topic Energy efficiency
Harmonics
Induction motors
Real-time monitoring
Voltage unbalance
description Different methods have been developed to estimate the energy efficiency of induction motors. The accuracy of these methods vary with the load factor, the unbalanced voltage (UV) and harmonics. The feasibility of these methods for efficiency estimation in real-time were theoretically and experimentally assessed during the operation under different operational conditions (i.e. balanced sinusoidal voltage (BSV), harmonics, UV and harmonics with UV). Results show that for load factors over 80%, the air-gap method is applicable under any condition, while the slip method is only applicable under BSV or balanced harmonic voltage. Moreover, for load factors over 40%, the nameplate method is applicable under BSV. Other methods result in errors over 8% and optimization methods are not applicable for real-time monitoring. Electric systems generally operates with some degree of UV and harmonics, while induction motors mostly operate with load factors below 60%, limiting the use of these methods for real-time measurement.
publishDate 2018
dc.date.issued.none.fl_str_mv 2018
dc.date.accessioned.none.fl_str_mv 2019-01-16T21:55:23Z
dc.date.available.none.fl_str_mv 2019-01-16T21:55:23Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.content.spa.fl_str_mv Text
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/acceptedVersion
format http://purl.org/coar/resource_type/c_6501
status_str acceptedVersion
dc.identifier.issn.spa.fl_str_mv 0957-0233
dc.identifier.uri.spa.fl_str_mv https://hdl.handle.net/11323/1988
dc.identifier.instname.spa.fl_str_mv Corporación Universidad de la Costa
dc.identifier.reponame.spa.fl_str_mv REDICUC - Repositorio CUC
dc.identifier.repourl.spa.fl_str_mv https://repositorio.cuc.edu.co/
identifier_str_mv 0957-0233
Corporación Universidad de la Costa
REDICUC - Repositorio CUC
url https://hdl.handle.net/11323/1988
https://repositorio.cuc.edu.co/
dc.language.iso.none.fl_str_mv eng
language eng
dc.rights.spa.fl_str_mv Atribución – No comercial – Compartir igual
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Atribución – No comercial – Compartir igual
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.publisher.spa.fl_str_mv Measurement
institution Corporación Universidad de la Costa
bitstream.url.fl_str_mv https://repositorio.cuc.edu.co/bitstreams/e4f3da35-bcc4-4eb7-94a5-dc3302943bd8/download
https://repositorio.cuc.edu.co/bitstreams/d6b7bf2f-de93-4a43-829a-9f4255a08095/download
https://repositorio.cuc.edu.co/bitstreams/21ba64c4-736a-4d4e-8027-9b062c4880b0/download
https://repositorio.cuc.edu.co/bitstreams/068209d2-9c7f-4097-9433-e2c69223b3c1/download
bitstream.checksum.fl_str_mv 2ccdae3735328fdec397fae34bb965b7
8a4605be74aa9ea9d79846c1fba20a33
9f5c136a1e353fcbfa5a47f2d13521cb
5ba2c323f2960c84d7f9a91ab8fb2c18
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio de la Universidad de la Costa CUC
repository.mail.fl_str_mv repdigital@cuc.edu.co
_version_ 1811760793463554048
spelling Sousa Santos, VladimirCabello Eras, Juan JoseSagastume Gutierrez, AlexisCabello Ulloa, Mario Javier2019-01-16T21:55:23Z2019-01-16T21:55:23Z20180957-0233https://hdl.handle.net/11323/1988Corporación Universidad de la CostaREDICUC - Repositorio CUChttps://repositorio.cuc.edu.co/Different methods have been developed to estimate the energy efficiency of induction motors. The accuracy of these methods vary with the load factor, the unbalanced voltage (UV) and harmonics. The feasibility of these methods for efficiency estimation in real-time were theoretically and experimentally assessed during the operation under different operational conditions (i.e. balanced sinusoidal voltage (BSV), harmonics, UV and harmonics with UV). Results show that for load factors over 80%, the air-gap method is applicable under any condition, while the slip method is only applicable under BSV or balanced harmonic voltage. Moreover, for load factors over 40%, the nameplate method is applicable under BSV. Other methods result in errors over 8% and optimization methods are not applicable for real-time monitoring. Electric systems generally operates with some degree of UV and harmonics, while induction motors mostly operate with load factors below 60%, limiting the use of these methods for real-time measurement.Sousa Santos, Vladimir-0000-0001-8808-1914-600Cabello Eras, Juan Jose-0000-0003-0949-0862-600Sagastume Gutierrez, Alexis-0000-0003-0188-7101-600Cabello Ulloa, Mario Javier-b9a8893b-9abd-4c08-9ddb-452314d3662e-0engMeasurementAtribución – No comercial – Compartir igualinfo:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Energy efficiencyHarmonicsInduction motorsReal-time monitoringVoltage unbalanceAssessment of the energy efficiency estimation methods on induction motors considering real-time monitoringArtículo de revistahttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1Textinfo:eu-repo/semantics/articlehttp://purl.org/redcol/resource_type/ARTinfo:eu-repo/semantics/acceptedVersionPublicationORIGINALPre-Print Manuscript measurement Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring.pdfPre-Print Manuscript measurement Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring.pdfapplication/pdf1267433https://repositorio.cuc.edu.co/bitstreams/e4f3da35-bcc4-4eb7-94a5-dc3302943bd8/download2ccdae3735328fdec397fae34bb965b7MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.cuc.edu.co/bitstreams/d6b7bf2f-de93-4a43-829a-9f4255a08095/download8a4605be74aa9ea9d79846c1fba20a33MD52THUMBNAILPre-Print Manuscript measurement Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring.pdf.jpgPre-Print Manuscript measurement Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring.pdf.jpgimage/jpeg52982https://repositorio.cuc.edu.co/bitstreams/21ba64c4-736a-4d4e-8027-9b062c4880b0/download9f5c136a1e353fcbfa5a47f2d13521cbMD54TEXTPre-Print Manuscript measurement Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring.pdf.txtPre-Print Manuscript measurement Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring.pdf.txttext/plain52323https://repositorio.cuc.edu.co/bitstreams/068209d2-9c7f-4097-9433-e2c69223b3c1/download5ba2c323f2960c84d7f9a91ab8fb2c18MD5511323/1988oai:repositorio.cuc.edu.co:11323/19882024-09-17 12:44:03.478open.accesshttps://repositorio.cuc.edu.coRepositorio de la Universidad de la Costa CUCrepdigital@cuc.edu.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