Shaft power estimation in induction motor operating under unbalanced and harmonics voltages
In this work the application of a method to estimate the shaft power of induction motors operating in the presences of unbalanced and harmonics voltages is presented. The method uses the steady state equivalent circuits, with some considerations for the analysis of motor performance, fed with unbala...
- Autores:
-
Sousa Santos, Vladimir
Viego, Percy Rafael
Gómez, Julio Rafael
Quispe, Enrique Ciro
Balbis Morejon, Milen
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2016
- Institución:
- Corporación Universidad de la Costa
- Repositorio:
- REDICUC - Repositorio CUC
- Idioma:
- eng
- OAI Identifier:
- oai:repositorio.cuc.edu.co:11323/4215
- Acceso en línea:
- https://hdl.handle.net/11323/4215
https://repositorio.cuc.edu.co/
- Palabra clave:
- Equivalent circuits
Harmonic analysis
Induction motors
Industrial power systems
Parameter estimation
Power quality
Unbalanced voltage
Circuitos equivalentes
Análisis armónico
Motores de induccion
Sistemas de potencia industriales
Estimación de parámetros
Calidad de potencia
Voltaje desequilibrado
- Rights
- openAccess
- License
- Attribution-NonCommercial-ShareAlike 4.0 International
id |
RCUC2_3a21c9590a7b92bb6c7cea8a13265c26 |
---|---|
oai_identifier_str |
oai:repositorio.cuc.edu.co:11323/4215 |
network_acronym_str |
RCUC2 |
network_name_str |
REDICUC - Repositorio CUC |
repository_id_str |
|
dc.title.spa.fl_str_mv |
Shaft power estimation in induction motor operating under unbalanced and harmonics voltages |
dc.title.translated.spa.fl_str_mv |
Estimación de la potencia del eje en el motor de inducción que funciona con tensiones desequilibradas y armónicas |
title |
Shaft power estimation in induction motor operating under unbalanced and harmonics voltages |
spellingShingle |
Shaft power estimation in induction motor operating under unbalanced and harmonics voltages Equivalent circuits Harmonic analysis Induction motors Industrial power systems Parameter estimation Power quality Unbalanced voltage Circuitos equivalentes Análisis armónico Motores de induccion Sistemas de potencia industriales Estimación de parámetros Calidad de potencia Voltaje desequilibrado |
title_short |
Shaft power estimation in induction motor operating under unbalanced and harmonics voltages |
title_full |
Shaft power estimation in induction motor operating under unbalanced and harmonics voltages |
title_fullStr |
Shaft power estimation in induction motor operating under unbalanced and harmonics voltages |
title_full_unstemmed |
Shaft power estimation in induction motor operating under unbalanced and harmonics voltages |
title_sort |
Shaft power estimation in induction motor operating under unbalanced and harmonics voltages |
dc.creator.fl_str_mv |
Sousa Santos, Vladimir Viego, Percy Rafael Gómez, Julio Rafael Quispe, Enrique Ciro Balbis Morejon, Milen |
dc.contributor.author.spa.fl_str_mv |
Sousa Santos, Vladimir Viego, Percy Rafael Gómez, Julio Rafael Quispe, Enrique Ciro Balbis Morejon, Milen |
dc.subject.spa.fl_str_mv |
Equivalent circuits Harmonic analysis Induction motors Industrial power systems Parameter estimation Power quality Unbalanced voltage Circuitos equivalentes Análisis armónico Motores de induccion Sistemas de potencia industriales Estimación de parámetros Calidad de potencia Voltaje desequilibrado |
topic |
Equivalent circuits Harmonic analysis Induction motors Industrial power systems Parameter estimation Power quality Unbalanced voltage Circuitos equivalentes Análisis armónico Motores de induccion Sistemas de potencia industriales Estimación de parámetros Calidad de potencia Voltaje desequilibrado |
description |
In this work the application of a method to estimate the shaft power of induction motors operating in the presences of unbalanced and harmonics voltages is presented. The method uses the steady state equivalent circuits, with some considerations for the analysis of motor performance, fed with unbalanced and harmonic voltages. The parameters of circuits are determined with low invasiveness, by applying a Bacterial Foraging Algorithm as technique of evolutionary search. With this, the shaft power can be estimated at any operating point. The method was tested in a 12.6 kW motor working in an industrial power supply grid, with harmonics and unbalanced voltage. |
publishDate |
2016 |
dc.date.issued.none.fl_str_mv |
2016 |
dc.date.accessioned.none.fl_str_mv |
2019-05-17T15:24:20Z |
dc.date.available.none.fl_str_mv |
2019-05-17T15:24:20Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/acceptedVersion |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
acceptedVersion |
dc.identifier.issn.spa.fl_str_mv |
15480992 |
dc.identifier.uri.spa.fl_str_mv |
https://hdl.handle.net/11323/4215 |
dc.identifier.instname.spa.fl_str_mv |
Corporación Universidad de la Costa |
dc.identifier.reponame.spa.fl_str_mv |
REDICUC - Repositorio CUC |
dc.identifier.repourl.spa.fl_str_mv |
https://repositorio.cuc.edu.co/ |
identifier_str_mv |
15480992 Corporación Universidad de la Costa REDICUC - Repositorio CUC |
url |
https://hdl.handle.net/11323/4215 https://repositorio.cuc.edu.co/ |
dc.language.iso.none.fl_str_mv |
eng |
language |
eng |
dc.rights.spa.fl_str_mv |
Attribution-NonCommercial-ShareAlike 4.0 International |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc-sa/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.coar.spa.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
rights_invalid_str_mv |
Attribution-NonCommercial-ShareAlike 4.0 International http://creativecommons.org/licenses/by-nc-sa/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.publisher.spa.fl_str_mv |
Universidad de la Costa |
institution |
Corporación Universidad de la Costa |
bitstream.url.fl_str_mv |
https://repositorio.cuc.edu.co/bitstreams/a21d61d9-c893-4d6b-9edb-6511dd6dda4b/download https://repositorio.cuc.edu.co/bitstreams/9350fa08-4a1b-4d49-839a-7e57c9844282/download https://repositorio.cuc.edu.co/bitstreams/f9c074f0-e73e-44ab-b443-144e8911f9e1/download https://repositorio.cuc.edu.co/bitstreams/c22bd7f3-b9ae-4f98-b87b-cdf66fdf2d04/download https://repositorio.cuc.edu.co/bitstreams/ae3bd3c7-e26c-45d2-be1b-5935afff5b3f/download |
bitstream.checksum.fl_str_mv |
934f4ca17e109e0a05eaeaba504d7ce4 8a4605be74aa9ea9d79846c1fba20a33 f7808abaaf0ef79522173ed410b917c2 7deb3ea668e0f2a35500027a801960d2 eaf0d193ce0c536e3bdac780d47f0b9f |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio de la Universidad de la Costa CUC |
repository.mail.fl_str_mv |
repdigital@cuc.edu.co |
_version_ |
1828166857341796352 |
spelling |
Sousa Santos, VladimirViego, Percy RafaelGómez, Julio RafaelQuispe, Enrique CiroBalbis Morejon, Milen2019-05-17T15:24:20Z2019-05-17T15:24:20Z201615480992https://hdl.handle.net/11323/4215Corporación Universidad de la CostaREDICUC - Repositorio CUChttps://repositorio.cuc.edu.co/In this work the application of a method to estimate the shaft power of induction motors operating in the presences of unbalanced and harmonics voltages is presented. The method uses the steady state equivalent circuits, with some considerations for the analysis of motor performance, fed with unbalanced and harmonic voltages. The parameters of circuits are determined with low invasiveness, by applying a Bacterial Foraging Algorithm as technique of evolutionary search. With this, the shaft power can be estimated at any operating point. The method was tested in a 12.6 kW motor working in an industrial power supply grid, with harmonics and unbalanced voltage.En este trabajo se aplica un método para estimar la potencia de inducción del eje. Los motores que funcionan en presencia de tensiones desequilibradas y armónicas son presentados el método utiliza los circuitos equivalentes de estado estable, con algunas consideraciones para el análisis del rendimiento del motor, alimentadas con desequilibrios y tensiones armónicas. Los parámetros de los circuitos se determinan con bajo. Invasividad, aplicando un algoritmo de forraje bacteriano como técnica de búsqueda evolutiva. Con esto, la potencia del eje se puede estimar en cualquier operación punto. El método fue probado en un motor de 12.6 kw trabajando en una potencia industrial. Red de suministro, con armónicos y tensión desequilibrada.Sousa Santos, Vladimir-0000-0001-8808-1914-600Viego, Percy Rafael-73186627-023b-4e63-af11-5eef74f4f434-0Gómez, Julio Rafael-36158e7a-d9e6-4448-8a78-a3ce97be46cf-0Quispe, Enrique Ciro-82fa64db-e560-4049-85e9-ee34bf04f8f7-0Balbis Morejon, Milen-0000-0002-8053-6651-600engUniversidad de la CostaAttribution-NonCommercial-ShareAlike 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-sa/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Equivalent circuitsHarmonic analysisInduction motorsIndustrial power systemsParameter estimationPower qualityUnbalanced voltageCircuitos equivalentesAnálisis armónicoMotores de induccionSistemas de potencia industrialesEstimación de parámetrosCalidad de potenciaVoltaje desequilibradoShaft power estimation in induction motor operating under unbalanced and harmonics voltagesEstimación de la potencia del eje en el motor de inducción que funciona con tensiones desequilibradas y armónicasArtículo de revistahttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1Textinfo:eu-repo/semantics/articlehttp://purl.org/redcol/resource_type/ARTinfo:eu-repo/semantics/acceptedVersionPublicationCC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-81031https://repositorio.cuc.edu.co/bitstreams/a21d61d9-c893-4d6b-9edb-6511dd6dda4b/download934f4ca17e109e0a05eaeaba504d7ce4MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.cuc.edu.co/bitstreams/9350fa08-4a1b-4d49-839a-7e57c9844282/download8a4605be74aa9ea9d79846c1fba20a33MD53ORIGINALShaft Power Estimation in Induction.pdfShaft Power Estimation in Induction.pdfapplication/pdf6450https://repositorio.cuc.edu.co/bitstreams/f9c074f0-e73e-44ab-b443-144e8911f9e1/downloadf7808abaaf0ef79522173ed410b917c2MD51THUMBNAILShaft Power Estimation in Induction.pdf.jpgShaft Power Estimation in Induction.pdf.jpgimage/jpeg35730https://repositorio.cuc.edu.co/bitstreams/c22bd7f3-b9ae-4f98-b87b-cdf66fdf2d04/download7deb3ea668e0f2a35500027a801960d2MD55TEXTShaft Power Estimation in Induction.pdf.txtShaft Power Estimation in Induction.pdf.txttext/plain1055https://repositorio.cuc.edu.co/bitstreams/ae3bd3c7-e26c-45d2-be1b-5935afff5b3f/downloadeaf0d193ce0c536e3bdac780d47f0b9fMD5611323/4215oai:repositorio.cuc.edu.co:11323/42152024-09-17 14:18:50.529http://creativecommons.org/licenses/by-nc-sa/4.0/Attribution-NonCommercial-ShareAlike 4.0 Internationalopen.accesshttps://repositorio.cuc.edu.coRepositorio de la Universidad de la Costa CUCrepdigital@cuc.edu.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 |