Simple voltammetric determination of iron in ethanol and biodiesel using a bismuth film coated glassy carbon electrode

Square-wave adsorptive stripping voltammetry (SWAdSV) was used to determine iron in ethanol and biodiesel using a bismuth-film electrode (BiFE) prepared onto the surface of a glassy carbon electrode (GCE) by electrochemical deposition to promote the reduction of Fe (III) previously complexed with 1-...

Full description

Autores:
Almeida, Joseany
P. Ribeiro, Ana Beatriz
Toloza Toloza, Carlos
Braga Alves, Ismael Carlos
N. Santos, José Ribamar
Martiniano de Azevedo, Lorena
Q. Aucélio, Ricardo
B. Marques, Aldaléa L.
Tipo de recurso:
Article of journal
Fecha de publicación:
2022
Institución:
Corporación Universidad de la Costa
Repositorio:
REDICUC - Repositorio CUC
Idioma:
eng
OAI Identifier:
oai:repositorio.cuc.edu.co:11323/9179
Acceso en línea:
https://hdl.handle.net/11323/9179
https://doi.org/10.1080/00032719.2022.2053701
https://repositorio.cuc.edu.co/
Palabra clave:
Fe (III)-1-(2-piridylazo)-2-naphthol
Tetramethylammonium hydroxide
Bismuth-film electrode
Square-wave adsorptive stripping voltammetry
Ethanol
Biodiesel
Rights
embargoedAccess
License
Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
Description
Summary:Square-wave adsorptive stripping voltammetry (SWAdSV) was used to determine iron in ethanol and biodiesel using a bismuth-film electrode (BiFE) prepared onto the surface of a glassy carbon electrode (GCE) by electrochemical deposition to promote the reduction of Fe (III) previously complexed with 1-(2-pyridylazo)-2-naphthol (PAN) directly in the electrochemical cell. The supporting electrolyte was composed by mixture of acetate buffer (0.1 mol L−1, pH 4.5) and ethanol (40/60% v/v) into which 500 µL of a 0.1 mmol L−1 stock solution of PAN was added as complexing agent. The Fe (III)-PAN complex presented a well-defined current peak at −0.7 V. For biodiesel, a treatment with tetramethylammonium hydroxide (TMAH) was proposed as an efficient mean to minimized matrix interferences. A limit of detection of 6.0 × 10−8 mol L−1 (0.06 µmol L−1) and limit of quantification of 2.0 × 10−7 mol L−1 (0.2 µmol L−1) were obtained for Fe(III). Under the optimized conditions, there were no significant interferences from Cu(II), Al(III), Mn(II), Cr(III), Cd(II), Zn(II) and Ni(II) and Pb(II) while Ni(II) interfered significantly. The analytical curves produced linear responses with equations I (µA) = (-1.315 × 10−7 ± 5.158 × 10−8) + (-0.238 ± 0.01) [Fe (III)] (µmol L−1), R2 = 0.992 and I (µA) = (-6.836 × 10−7 ± 1.124 × 10−8) + (-0.408 ± 0.013) [Fe (III)] (µmol L−1), R2=0.998 for pure ethanol and biodiesel, respectively. The method produced satisfactory results in quantifying original quantities of Fe(III) in fuel ethanol (5.65 ± 0.71 µmol L−1) and biodiesel (1.28 ± 0.25 µmol L−1) at a 95% confidence limit (n = 3).