Evaluación termodinámica de las estructuras de concreto masivo: estudio del nuevo puente Pumarejo

The thermodynamic evaluation of the massive concrete structures of the New Pumarejo Bridge considers its study in the bases of the main piles of the same, specifically in piles 13 and 14, these thermodynamic evaluations were carried out by means of special thermometers located and distributed in the...

Full description

Autores:
Rodríguez Cabarcas, Diego Alejandro
Tipo de recurso:
Trabajo de grado de pregrado
Fecha de publicación:
2019
Institución:
Corporación Universidad de la Costa
Repositorio:
REDICUC - Repositorio CUC
Idioma:
spa
OAI Identifier:
oai:repositorio.cuc.edu.co:11323/4918
Acceso en línea:
https://hdl.handle.net/11323/4918
https://repositorio.cuc.edu.co/
Palabra clave:
Concreto masivo
Termodinámica
Puente
Temperatura
Modelo estadístico
Hormigón
Encepado
Rights
openAccess
License
Attribution-NonCommercial-ShareAlike 4.0 International
id RCUC2_1b4a64dd280d1cbfda01163ab4c980ab
oai_identifier_str oai:repositorio.cuc.edu.co:11323/4918
network_acronym_str RCUC2
network_name_str REDICUC - Repositorio CUC
repository_id_str
dc.title.spa.fl_str_mv Evaluación termodinámica de las estructuras de concreto masivo: estudio del nuevo puente Pumarejo
title Evaluación termodinámica de las estructuras de concreto masivo: estudio del nuevo puente Pumarejo
spellingShingle Evaluación termodinámica de las estructuras de concreto masivo: estudio del nuevo puente Pumarejo
Concreto masivo
Termodinámica
Puente
Temperatura
Modelo estadístico
Hormigón
Encepado
title_short Evaluación termodinámica de las estructuras de concreto masivo: estudio del nuevo puente Pumarejo
title_full Evaluación termodinámica de las estructuras de concreto masivo: estudio del nuevo puente Pumarejo
title_fullStr Evaluación termodinámica de las estructuras de concreto masivo: estudio del nuevo puente Pumarejo
title_full_unstemmed Evaluación termodinámica de las estructuras de concreto masivo: estudio del nuevo puente Pumarejo
title_sort Evaluación termodinámica de las estructuras de concreto masivo: estudio del nuevo puente Pumarejo
dc.creator.fl_str_mv Rodríguez Cabarcas, Diego Alejandro
dc.contributor.advisor.spa.fl_str_mv Pereira García, Diego
dc.contributor.author.spa.fl_str_mv Rodríguez Cabarcas, Diego Alejandro
dc.subject.spa.fl_str_mv Concreto masivo
Termodinámica
Puente
Temperatura
Modelo estadístico
Hormigón
Encepado
topic Concreto masivo
Termodinámica
Puente
Temperatura
Modelo estadístico
Hormigón
Encepado
description The thermodynamic evaluation of the massive concrete structures of the New Pumarejo Bridge considers its study in the bases of the main piles of the same, specifically in piles 13 and 14, these thermodynamic evaluations were carried out by means of special thermometers located and distributed in the different phases of concreting of the pile caps; the pile caps are a strongly reinforced structural element whose main function is to link groups of piles, it behaves like a shoe and also serves as a base for the piles; the pile caps of the pylons were cast in 3 phases due to their high volume of concrete, for which reason they are given the name of massive concrete. This research includes the continuous development of different stages that starts from the bibliographic collection and review of the temperatures obtained in each phase of concreting of these structural elements, elaboration of graphs, correlations, and analysis of the results that allows integrating all the results in a model statistical. Between 8 - 10 points of thermodynamic tests were carried out for each phase of melting in the caps of the two main piles using a thermocouple type K, which are a temperature sensor capable of storing information every certain time defined, for this case every 10 minutes the thermocouples marked the temperature of the element in the position that it was. The pile cap has a height of 4.5m, each phase of casting was made every 1.25m and the thermocouples were generally positioned at half the height of each phase, ie; 0.6m for phase 1, 1.25m for phase 2 and 2.25m for phase 3. In turn, the ambient temperature was also taken at each measurement. The maximum temperatures did not exceed the concrete placement limit established by the ACI of 70°C. Due to the geographic conditions of the project, its proximity to the sea and the humidity of the area, it is necessary to lower the temperature levels of the concrete. In the New Pumarejo Bridge the control and handling of the temperature were achieved by taking measures such as; change a percentage of water for ice in the mix, moisten the drum of the mixer trucks, shade aggregates with a cloth and wet them, replace cement with kiln slag. By generating these changes in the treatment of materials and equipment involved in the process of manufacturing the concrete were obtained casting temperatures of 27.7°C and an ambient of about 27.9°C, and the average maximum temperature it is 63.5°C in the element.
publishDate 2019
dc.date.accessioned.none.fl_str_mv 2019-06-28T15:38:39Z
dc.date.available.none.fl_str_mv 2019-06-28T15:38:39Z
dc.date.issued.none.fl_str_mv 2019
dc.type.spa.fl_str_mv Trabajo de grado - Pregrado
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_7a1f
dc.type.content.spa.fl_str_mv Text
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/bachelorThesis
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/TP
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/acceptedVersion
format http://purl.org/coar/resource_type/c_7a1f
status_str acceptedVersion
dc.identifier.uri.spa.fl_str_mv https://hdl.handle.net/11323/4918
dc.identifier.instname.spa.fl_str_mv Corporación Universidad de la Costa
dc.identifier.reponame.spa.fl_str_mv REDICUC - Repositorio CUC
dc.identifier.repourl.spa.fl_str_mv https://repositorio.cuc.edu.co/
url https://hdl.handle.net/11323/4918
https://repositorio.cuc.edu.co/
identifier_str_mv Corporación Universidad de la Costa
REDICUC - Repositorio CUC
dc.language.iso.none.fl_str_mv spa
language spa
dc.relation.references.spa.fl_str_mv ACI. (2007). Specification for Hot Weather Concreting. En A. C. 305, ACI 305.1-06 (pág. 12). Estados Unidos: American Concrete Institute, Farmington Hills. ACI116, C. (2006). Terminología del cemento y el hormigón. Terminología del cemento y el hormigón. ACI301-10. (2010). Specifications for Structural Concrete. Farmington Hills: American Concrete Institute. ACI305.1-06 (2007). Specifications for Hot weather concreting. Farmington Hills: American Concrete Institute. AASHTO LRFD Bridge Desing Specifications, IV edición 2007 AASHTO Bridge Security Guidelines. AASHTO Guide Specifications for LRFD Seismic Bridge Design II Edition 2011. Aguas Medina, D. d., Peña Coronado, K. E., & Ospino Árias, J. C. (2017). El canal navegable del Rio Magdalena y las sinergias para el desarrollo de Barranquilla. . Dimensión Empresarial, 15 (2), 211-240. Bamonte, P., & Gambarova, P. (2010). Properties of Concrete Subjected to. Journal of Structural Fire Engineering, 47-61. Barreda, M., Iaiani, C., & Sota, J. D. (2000). Hormigón reforzado con fibras de polipropileno: Tramo experimental de un pavimento de hormigon. Jornadas SAM 2000 - IV Coloquio Latinoamericano de Fractura y Fatiga, 1145-1150. Borrajo Pérez, R., González Bayón, J. J., & Sánchez Rodríguez, A. (2012). Modelación del proceso de calcinación flash durante la activación de arcillas. Ingeniería Mecánica. Vol. 15. No. 1, 73-82. Calavera, J. (2015). El aumento de temperatura del hormigón durante los primeros días a partir del vertido. Hormigón y Acero, 84 - 85. Cámara, A., & Astiz, M. Á. (2014). Aplicabilidad de las diversas estrategias de análisis sísmico en puentes atirantados en rango elástico. Revista Internacional de Métodos Numéricos para Cálculo y Diseño en Ingeniería. 30 (1), 42-50. Carillo Alonso, L., & Astiz Suárez, M. Á. (2015). Introducción de errores aleatorios en el proceso de instalación de los cables en los puentes atirantados. Hormigón y Acero. Vol. 66 N° 277, 203-224. Conrado, T., & San jose, A. (2016). PERCEPCIÓN DE LOS FACTORES INFLUYENTES EN LA CALIDAD DEL. Barranquilla: INGECUC. Fernandez Canovas, M. (1991). Influencia de la temperatura de curado sobre la evolución de las resistencias a compresiónde hormigones fabrizados con distintos tipos de cementos. Materiales de construcción, Vol 41, N°222, 37-46. Fernández Troyano, L., Ayuso Calle, G., & Fernández Muñoz, L. (2016). Distintos sistemas de aislamiento empleados en puentes. Hormigón y Acero, 1-11. doi:http://dx.doi.org/10.1016/j.hya.2016.09.003 ACI. (2007). Specification for Hot Weather Concreting. En A. C. 305, ACI 305.1-06 (pág. 12). Estados Unidos: American Concrete Institute, Farmington Hills. ACI116, C. (2006). Terminología del cemento y el hormigón. Terminología del cemento y el hormigón. ACI301-10. (2010). Specifications for Structural Concrete. Farmington Hills: American Concrete Institute. Aguas Medina, D. d., Peña Coronado, K. E., & Ospino Árias, J. C. (2017). El canal navegable del Rio Magdalena y las sinergias para el desarrollo de Barranquilla. . Dimensión Empresarial, 15 (2), 211-240. Bamonte, P., & Gambarova, P. (2010). Properties of Concrete Subjected to. Journal of Structural Fire Engineering, 47-61. Barreda, M., Iaiani, C., & Sota, J. D. (2000). Hormigón reforzado con fibras de polipropileno: Tramo experimental de un pavimento de hormigon. Jornadas SAM 2000 - IV Coloquio Latinoamericano de Fractura y Fatiga, 1145-1150. Borrajo Pérez, R., González Bayón, J. J., & Sánchez Rodríguez, A. (2012). Modelación del proceso de calcinación flash durante la activación de arcillas. Ingeniería Mecánica. Vol. 15. No. 1, 73-82. Calavera, J. (2015). El aumento de temperatura del hormigón durante los primeros días a partir del vertido. Hormigón y Acero, 84 - 85. Cámara, A., & Astiz, M. Á. (2014). Aplicabilidad de las diversas estrategias de análisis sísmico en puentes atirantados en rango elástico. Revista Internacional de Métodos Numéricos para Cálculo y Diseño en Ingeniería. 30 (1), 42-50. Carillo Alonso, L., & Astiz Suárez, M. Á. (2015). Introducción de errores aleatorios en el proceso de instalación de los cables en los puentes atirantados. Hormigón y Acero. Vol. 66 N° 277, 203-224. Conrado, T., & San jose, A. (2016). PERCEPCIÓN DE LOS FACTORES INFLUYENTES EN LA CALIDAD DEL. Barranquilla: INGECUC. Código Colombiano de diseño sísmico de puentes (CCDSP), VI edición 2011. Especificaciones generales de construccion de carreteras del Invias. Fernandez Canovas, M. (1991). Influencia de la temperatura de curado sobre la evolución de las resistencias a compresiónde hormigones fabrizados con distintos tipos de cementos. Materiales de construcción, Vol 41, N°222, 37-46. Fernández Troyano, L., Ayuso Calle, G., & Fernández Muñoz, L. (2016). Distintos sistemas de aislamiento empleados en puentes. Hormigón y Acero, 1-11. doi:http://dx.doi.org/10.1016/j.hya.2016.09.003 Garín, L., Santilli, A., & Pejoja, E. (2012). Influencia del curado en la resistencia a compresión del hormigón: estudio experimental. Memoria de Trabajos de Difusión Científica y Técnica, núm. 10 -ISSN 1510-7450 • ISSN (en línea) 1688-9584, 109-114. Garin, L., Santillini, A., & Pejoja, E. (2012). Influencia del curado en la resistencia a compresión del hormigon. Memoria de Trabajos de Difusión Cientifica y Técnica. Herrera, R. N. (2011). Adecuada aplicacion del contro termico y de madurez del concreto (calorimetrias del concreto) en la determinacion de tiempos de desmolde y descimbre en vivienda. 20. Juan, M. (2012). Influencia de la Temperatura Ambiental sobre la resistencia del hormigón preparado. Ciencias aplicadas; 624 - Ingeniería civil y de la construcción en general, 23-37. Lopez, L. G. (2003). EL CONCRETO Y OTROS MATERIALES PARA LA CONSTRUCCION. Manizales: UNIVERSIDAD NACIONAL. Martínez Galván, S. A., & Romo Organista, M. P. (2013). Capacidad de carga tridimensional de celdas estructuradas apoyadas en suelo cohesivo: método de análisis simplificado. Ingeniería Investigación y Tecnología, Vol. XIV, N°3, 399-412. Merritt, F. S. (1993). Manual del Ingeniero Civil. Gran Bretaña: McGraw Hill. Muñoz, E., & Gómez, D. (2013). Análisis de la evolución de los daños en los puentes de Colombia. Revista de Ingeniería de Construcción RIC. Vol. 28 N°1, 37-62. NSR-10. (2010). Reglamento Colombiano De Construccion Sismo Resistente. Bogota: Ministerio de Ambiente, Vivienda y Desarrollo Territorial. Ortiz Lozano, J. A., Aguado de Cea, A., Zermeño de León, M. E., & Alonso Farrera, F. A. (2007). Influencia de la temperatura ambiental en las propiedades del concreto hidráulico. Ingenieria 11-2, 13-20. Ortiz, J., Aguado, A., Agullo, L., Garcia, T., & Zermeño, M. (2008). Estudio experimental sobre la influencia de la temperatura ambiental en la resistencia del hormigón preparado. Bases teóricas. Materiales de Construccion Vol. 58, 7-22. Pacheco Bustos, C. A., Fuentes Pumarejo, L., Sánchez Cotte, É., & Rondón Quintana, H. (2017). Residuos de construcción y demolición (RCD), una perspectiva de aprovechamiento para la ciudad de barranquilla desde su modelo de gestión. Ingenieria y Desarrollo. Vol. 35 N°2, 533-555. Padilla, J. (2014). Contrato 2200 – Diciembre 2011 para la complementación de los estudios y diseños definitivos (fase III) para la Solución Integral del paso sobre el Río Magdalena en Barranquilla. Barranquilla: VOLUMEN No. VIII: ESTUDIO Y DISEÑO DE ESTRUCTURAS. Páez Moreno, D. F., Leal Moreno, V. E., & Restrepo Burgos , M. (2009). INFLUENCIA DE LOS CICLOS HIELO-DESHIELO EN LA RESISTENCIA DEL CONCRETO (CASO TUNJA). Revista Ingenierías Universidad de Medellín, vol. 8, No. 15 especial, 95-110. Palomino, J. (2014). GUIA PARA SUPERVISIÓN TÉCNICA DE ESTRUCTURAS DE CONCRETO REFORZADO. Cartagena: Universidad de Cartagena. Quimbay Herrera, R. N. (2009). "ADECUADA APLICACION DEL CONTROL TERMICO Y DE MADUREZ DEL CONCRETO (CALORIMETRIAS DEL CONCRETO) EN LA DETERMINACION DE TIEMPOS DE DESMOLDE Y DESCIMBRE EN VIVIENDA". Quintana Ytza, M. F. (2009). Metodos Constructivos de Puentes Atirantados - Estudio de la Distribucion de Fuerzas en los Tierantes. Memoria de Trabajos de Difusion Cientifica y Tecnica, 13-28. Ramírez, L. C. (2008). El Concreto Masivo. Ciudad de Mexico: PROGRAMA DE MAESTRÍA Y DOCTORADO EN INGENIERÍA. Ramírez, L. C. (Enero de 2008). El Concreto Masivo. Ciudad de Mexico: PROGRAMA DE MAESTRÍA Y DOCTORADO EN INGENIERÍA. Reglamento colombiano de construcción sismorresistente NSR10 decreto 926 de marzo 19 de 2010. Rhodes, J. A. (1978). Propiedades térmicas: Importancia de las pruebas y propiedades del hormigón y materiales para la fabricación de hormigón. STP-169B, ASTM International, West Conshohocken, Pa., 242-266. Roa Rodríguez, G., Aperador Chaparro, W., & Delgado Tobón, E. (2015). Diseño de sistema de monitoreo remoto para evaluación de la corrosión en estructuras de concreto reforzado sometidas a ion cloruro. Ingeniería Investigación y Tecnología, Vol. XVI N° 4, 565-572. Ruiz Guerrero, J. (Junio de 2011). Repositorio Tec . Obtenido de Repositorio Institucional del Tecnológico de Costa Rica: https://repositoriotec.tec.ac.cr/handle/2238/6791 Sima, F., & Knut, S. (2014). Evolución de los Puentes Atirantados. FIRST INTERNATIONAL BRIDGES CONFERENCE - CHILE 2014, FUTURE CHALLENGES: DESIGN, CONSTRUCTION AND MAINTENANCE, (págs. 1-8). Santiago - CHILE. Obtenido de https://www.researchgate.net/profile/Fernando_Sima/publication/315825341_Evolucion_de_los_Puentes_Atirantados/links/58e8f4c4aca2729d8cd2acee/Evolucion-de-los-Puentes-Atirantados.pdf Solet Salamero, G. (2012, Febrero). Tesis: Puentes de Fortuna. Universidad Politécnica de Catalunya. Solis Carcaño, R., & I. Moreno, E. (2005). Influencia del curado húmedo en la resistencia a compresión del concreto en clima cálido subhúmedo. Ingenieria 9-3, 5-17. Solís Carcaño, R., & Moreno, E. I. (2006). Análisis de la porosidad del concreto con agregado calizo. Revista de la Facultad de Ingeniería de la U.C.V., Vol. 21, N° 3, 57-68. Toirac Corral, J. (2004). Patología de la construcción. Grietas y Fisuras en obras de Hormigón. Origen y Prevención. . Ciencia y Sociedad. Vol. XXIX, N°1, 72-114. Varona, F. B., Baena, F. J., & Ivorra, S. (2017). Estudio de las propiedades mecánicas residuales de hormigones expuestos a altas temperaturas. Hormigón y Acero, 1-7.
dc.rights.spa.fl_str_mv Attribution-NonCommercial-ShareAlike 4.0 International
dc.rights.uri.spa.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Attribution-NonCommercial-ShareAlike 4.0 International
http://creativecommons.org/licenses/by-nc-sa/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.publisher.spa.fl_str_mv Universidad de la Costa
dc.publisher.program.spa.fl_str_mv Ingeniería Civil
institution Corporación Universidad de la Costa
bitstream.url.fl_str_mv https://repositorio.cuc.edu.co/bitstreams/2cbce097-fb9a-48cc-a207-f18812ba86e7/download
https://repositorio.cuc.edu.co/bitstreams/de847fb7-3a1a-42d2-9127-e7faa39c337e/download
https://repositorio.cuc.edu.co/bitstreams/89bb0d1d-f0f4-4183-8480-ee050007a7c4/download
https://repositorio.cuc.edu.co/bitstreams/106409fd-02af-412b-badd-edf81d70f012/download
https://repositorio.cuc.edu.co/bitstreams/00182f29-fc54-4ddb-9960-328830850907/download
bitstream.checksum.fl_str_mv 31d6313aed2d494a1b7f51e26217e894
934f4ca17e109e0a05eaeaba504d7ce4
8a4605be74aa9ea9d79846c1fba20a33
b721b14f6bc08b595cb1be6e46774ca9
e2b17fb31011a40daac0d9af8aad7679
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio de la Universidad de la Costa CUC
repository.mail.fl_str_mv repdigital@cuc.edu.co
_version_ 1828166904531910656
spelling Pereira García, DiegoRodríguez Cabarcas, Diego Alejandro2019-06-28T15:38:39Z2019-06-28T15:38:39Z2019https://hdl.handle.net/11323/4918Corporación Universidad de la CostaREDICUC - Repositorio CUChttps://repositorio.cuc.edu.co/The thermodynamic evaluation of the massive concrete structures of the New Pumarejo Bridge considers its study in the bases of the main piles of the same, specifically in piles 13 and 14, these thermodynamic evaluations were carried out by means of special thermometers located and distributed in the different phases of concreting of the pile caps; the pile caps are a strongly reinforced structural element whose main function is to link groups of piles, it behaves like a shoe and also serves as a base for the piles; the pile caps of the pylons were cast in 3 phases due to their high volume of concrete, for which reason they are given the name of massive concrete. This research includes the continuous development of different stages that starts from the bibliographic collection and review of the temperatures obtained in each phase of concreting of these structural elements, elaboration of graphs, correlations, and analysis of the results that allows integrating all the results in a model statistical. Between 8 - 10 points of thermodynamic tests were carried out for each phase of melting in the caps of the two main piles using a thermocouple type K, which are a temperature sensor capable of storing information every certain time defined, for this case every 10 minutes the thermocouples marked the temperature of the element in the position that it was. The pile cap has a height of 4.5m, each phase of casting was made every 1.25m and the thermocouples were generally positioned at half the height of each phase, ie; 0.6m for phase 1, 1.25m for phase 2 and 2.25m for phase 3. In turn, the ambient temperature was also taken at each measurement. The maximum temperatures did not exceed the concrete placement limit established by the ACI of 70°C. Due to the geographic conditions of the project, its proximity to the sea and the humidity of the area, it is necessary to lower the temperature levels of the concrete. In the New Pumarejo Bridge the control and handling of the temperature were achieved by taking measures such as; change a percentage of water for ice in the mix, moisten the drum of the mixer trucks, shade aggregates with a cloth and wet them, replace cement with kiln slag. By generating these changes in the treatment of materials and equipment involved in the process of manufacturing the concrete were obtained casting temperatures of 27.7°C and an ambient of about 27.9°C, and the average maximum temperature it is 63.5°C in the element.La evaluación termodinámica de las estructuras de concreto masivo del nuevo Puente Pumarejo se centró en el análisis de las bases de las pilas principales del mismo, específicamente en los pilonos 13 y 14; estas evaluaciones termodinámicas se realizaron por medio de termómetros especiales ubicados y distribuidos en las diferentes fases de hormigonados de los encepados. Los encepados son un elemento estructural fuertemente armado que tiene como principal función enlazar grupos de pilotes, se comporta como una zapata y además sirve de base para los pilonos; los encepados de los pilonos fueron fundidos en 3 fases debido a su alto volumen de concreto, por lo que se les da el nombre de concretos masivos. El presente proyecto investigativo comprende el desarrollo continuo de diferentes etapas que inicia desde la recopilación bibliográfica y revisión de las temperaturas obtenidas en cada fase de hormigonado de estos elementos estructurales, elaboración de gráficas, determinación de las correlaciones y análisis de los resultados que permita integrar todos los en un modelo estadístico. Se desarrollaron entre 8 – 10 puntos de ensayos termodinámicos por cada fase de fundida en los encepados de los dos pilonos principales utilizando una termocupla tipo K, que cuenta con un sensor de temperatura capaz de almacenar información cada cierto tiempo definido, para este caso, cada 10 minutos las termocuplas marcaban la temperatura del elemento en la posición que se encontrara. El encepado tiene una altura de 6.5m. Cada fase de fundida se hizo de 1.25m y las termocuplas generalmente se posicionaban a la mitad de la altura de cada fase, es decir; 0.6m para la fase 1, 1.25m para la fase 2 y 2.65m para la fase 3. A su vez, la temperatura ambiente también fue tomada en cada medición. Las temperaturas máximas no sobrepasaron el límite de colocación de concreto establecido por la ACI de 70°C. Debido a las condiciones geográficas del proyecto, su cercanía con el mar y la humedad de la zona se hace necesario bajar los niveles de temperatura del hormigón, esto tiene como objetivo evitar la fisuración por retracción. En el nuevo Puente Pumarejo el control y manejo de la temperatura se logró tomando medidas tales como; cambiar un porcentaje de agua por hielo en la mezcla, humedecer el tambor de los camiones mixer, ensombrecer áridos con polisombra y humectarlos, reemplazo de cemento por escorias de horno. Al generar estos cambios en el tratado de los materiales y los equipos que intervienen en el proceso de fabricación del concreto se obtuvieron temperaturas de vaciado de 27,7°C y de ambiente de unos 27,9°C, y el promedio de temperatura máxima es de 63,5°C en los elementos.spaUniversidad de la CostaIngeniería CivilAttribution-NonCommercial-ShareAlike 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-sa/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Concreto masivoTermodinámicaPuenteTemperaturaModelo estadísticoHormigónEncepadoEvaluación termodinámica de las estructuras de concreto masivo: estudio del nuevo puente PumarejoTrabajo de grado - Pregradohttp://purl.org/coar/resource_type/c_7a1fTextinfo:eu-repo/semantics/bachelorThesishttp://purl.org/redcol/resource_type/TPinfo:eu-repo/semantics/acceptedVersionACI. (2007). Specification for Hot Weather Concreting. En A. C. 305, ACI 305.1-06 (pág. 12). Estados Unidos: American Concrete Institute, Farmington Hills. ACI116, C. (2006). Terminología del cemento y el hormigón. Terminología del cemento y el hormigón. ACI301-10. (2010). Specifications for Structural Concrete. Farmington Hills: American Concrete Institute. ACI305.1-06 (2007). Specifications for Hot weather concreting. Farmington Hills: American Concrete Institute. AASHTO LRFD Bridge Desing Specifications, IV edición 2007 AASHTO Bridge Security Guidelines. AASHTO Guide Specifications for LRFD Seismic Bridge Design II Edition 2011. Aguas Medina, D. d., Peña Coronado, K. E., & Ospino Árias, J. C. (2017). El canal navegable del Rio Magdalena y las sinergias para el desarrollo de Barranquilla. . Dimensión Empresarial, 15 (2), 211-240. Bamonte, P., & Gambarova, P. (2010). Properties of Concrete Subjected to. Journal of Structural Fire Engineering, 47-61. Barreda, M., Iaiani, C., & Sota, J. D. (2000). Hormigón reforzado con fibras de polipropileno: Tramo experimental de un pavimento de hormigon. Jornadas SAM 2000 - IV Coloquio Latinoamericano de Fractura y Fatiga, 1145-1150. Borrajo Pérez, R., González Bayón, J. J., & Sánchez Rodríguez, A. (2012). Modelación del proceso de calcinación flash durante la activación de arcillas. Ingeniería Mecánica. Vol. 15. No. 1, 73-82. Calavera, J. (2015). El aumento de temperatura del hormigón durante los primeros días a partir del vertido. Hormigón y Acero, 84 - 85. Cámara, A., & Astiz, M. Á. (2014). Aplicabilidad de las diversas estrategias de análisis sísmico en puentes atirantados en rango elástico. Revista Internacional de Métodos Numéricos para Cálculo y Diseño en Ingeniería. 30 (1), 42-50. Carillo Alonso, L., & Astiz Suárez, M. Á. (2015). Introducción de errores aleatorios en el proceso de instalación de los cables en los puentes atirantados. Hormigón y Acero. Vol. 66 N° 277, 203-224. Conrado, T., & San jose, A. (2016). PERCEPCIÓN DE LOS FACTORES INFLUYENTES EN LA CALIDAD DEL. Barranquilla: INGECUC. Fernandez Canovas, M. (1991). Influencia de la temperatura de curado sobre la evolución de las resistencias a compresiónde hormigones fabrizados con distintos tipos de cementos. Materiales de construcción, Vol 41, N°222, 37-46. Fernández Troyano, L., Ayuso Calle, G., & Fernández Muñoz, L. (2016). Distintos sistemas de aislamiento empleados en puentes. Hormigón y Acero, 1-11. doi:http://dx.doi.org/10.1016/j.hya.2016.09.003 ACI. (2007). Specification for Hot Weather Concreting. En A. C. 305, ACI 305.1-06 (pág. 12). Estados Unidos: American Concrete Institute, Farmington Hills. ACI116, C. (2006). Terminología del cemento y el hormigón. Terminología del cemento y el hormigón. ACI301-10. (2010). Specifications for Structural Concrete. Farmington Hills: American Concrete Institute. Aguas Medina, D. d., Peña Coronado, K. E., & Ospino Árias, J. C. (2017). El canal navegable del Rio Magdalena y las sinergias para el desarrollo de Barranquilla. . Dimensión Empresarial, 15 (2), 211-240. Bamonte, P., & Gambarova, P. (2010). Properties of Concrete Subjected to. Journal of Structural Fire Engineering, 47-61. Barreda, M., Iaiani, C., & Sota, J. D. (2000). Hormigón reforzado con fibras de polipropileno: Tramo experimental de un pavimento de hormigon. Jornadas SAM 2000 - IV Coloquio Latinoamericano de Fractura y Fatiga, 1145-1150. Borrajo Pérez, R., González Bayón, J. J., & Sánchez Rodríguez, A. (2012). Modelación del proceso de calcinación flash durante la activación de arcillas. Ingeniería Mecánica. Vol. 15. No. 1, 73-82. Calavera, J. (2015). El aumento de temperatura del hormigón durante los primeros días a partir del vertido. Hormigón y Acero, 84 - 85. Cámara, A., & Astiz, M. Á. (2014). Aplicabilidad de las diversas estrategias de análisis sísmico en puentes atirantados en rango elástico. Revista Internacional de Métodos Numéricos para Cálculo y Diseño en Ingeniería. 30 (1), 42-50. Carillo Alonso, L., & Astiz Suárez, M. Á. (2015). Introducción de errores aleatorios en el proceso de instalación de los cables en los puentes atirantados. Hormigón y Acero. Vol. 66 N° 277, 203-224. Conrado, T., & San jose, A. (2016). PERCEPCIÓN DE LOS FACTORES INFLUYENTES EN LA CALIDAD DEL. Barranquilla: INGECUC. Código Colombiano de diseño sísmico de puentes (CCDSP), VI edición 2011. Especificaciones generales de construccion de carreteras del Invias. Fernandez Canovas, M. (1991). Influencia de la temperatura de curado sobre la evolución de las resistencias a compresiónde hormigones fabrizados con distintos tipos de cementos. Materiales de construcción, Vol 41, N°222, 37-46. Fernández Troyano, L., Ayuso Calle, G., & Fernández Muñoz, L. (2016). Distintos sistemas de aislamiento empleados en puentes. Hormigón y Acero, 1-11. doi:http://dx.doi.org/10.1016/j.hya.2016.09.003 Garín, L., Santilli, A., & Pejoja, E. (2012). Influencia del curado en la resistencia a compresión del hormigón: estudio experimental. Memoria de Trabajos de Difusión Científica y Técnica, núm. 10 -ISSN 1510-7450 • ISSN (en línea) 1688-9584, 109-114. Garin, L., Santillini, A., & Pejoja, E. (2012). Influencia del curado en la resistencia a compresión del hormigon. Memoria de Trabajos de Difusión Cientifica y Técnica. Herrera, R. N. (2011). Adecuada aplicacion del contro termico y de madurez del concreto (calorimetrias del concreto) en la determinacion de tiempos de desmolde y descimbre en vivienda. 20. Juan, M. (2012). Influencia de la Temperatura Ambiental sobre la resistencia del hormigón preparado. Ciencias aplicadas; 624 - Ingeniería civil y de la construcción en general, 23-37. Lopez, L. G. (2003). EL CONCRETO Y OTROS MATERIALES PARA LA CONSTRUCCION. Manizales: UNIVERSIDAD NACIONAL. Martínez Galván, S. A., & Romo Organista, M. P. (2013). Capacidad de carga tridimensional de celdas estructuradas apoyadas en suelo cohesivo: método de análisis simplificado. Ingeniería Investigación y Tecnología, Vol. XIV, N°3, 399-412. Merritt, F. S. (1993). Manual del Ingeniero Civil. Gran Bretaña: McGraw Hill. Muñoz, E., & Gómez, D. (2013). Análisis de la evolución de los daños en los puentes de Colombia. Revista de Ingeniería de Construcción RIC. Vol. 28 N°1, 37-62. NSR-10. (2010). Reglamento Colombiano De Construccion Sismo Resistente. Bogota: Ministerio de Ambiente, Vivienda y Desarrollo Territorial. Ortiz Lozano, J. A., Aguado de Cea, A., Zermeño de León, M. E., & Alonso Farrera, F. A. (2007). Influencia de la temperatura ambiental en las propiedades del concreto hidráulico. Ingenieria 11-2, 13-20. Ortiz, J., Aguado, A., Agullo, L., Garcia, T., & Zermeño, M. (2008). Estudio experimental sobre la influencia de la temperatura ambiental en la resistencia del hormigón preparado. Bases teóricas. Materiales de Construccion Vol. 58, 7-22. Pacheco Bustos, C. A., Fuentes Pumarejo, L., Sánchez Cotte, É., & Rondón Quintana, H. (2017). Residuos de construcción y demolición (RCD), una perspectiva de aprovechamiento para la ciudad de barranquilla desde su modelo de gestión. Ingenieria y Desarrollo. Vol. 35 N°2, 533-555. Padilla, J. (2014). Contrato 2200 – Diciembre 2011 para la complementación de los estudios y diseños definitivos (fase III) para la Solución Integral del paso sobre el Río Magdalena en Barranquilla. Barranquilla: VOLUMEN No. VIII: ESTUDIO Y DISEÑO DE ESTRUCTURAS. Páez Moreno, D. F., Leal Moreno, V. E., & Restrepo Burgos , M. (2009). INFLUENCIA DE LOS CICLOS HIELO-DESHIELO EN LA RESISTENCIA DEL CONCRETO (CASO TUNJA). Revista Ingenierías Universidad de Medellín, vol. 8, No. 15 especial, 95-110. Palomino, J. (2014). GUIA PARA SUPERVISIÓN TÉCNICA DE ESTRUCTURAS DE CONCRETO REFORZADO. Cartagena: Universidad de Cartagena. Quimbay Herrera, R. N. (2009). "ADECUADA APLICACION DEL CONTROL TERMICO Y DE MADUREZ DEL CONCRETO (CALORIMETRIAS DEL CONCRETO) EN LA DETERMINACION DE TIEMPOS DE DESMOLDE Y DESCIMBRE EN VIVIENDA". Quintana Ytza, M. F. (2009). Metodos Constructivos de Puentes Atirantados - Estudio de la Distribucion de Fuerzas en los Tierantes. Memoria de Trabajos de Difusion Cientifica y Tecnica, 13-28. Ramírez, L. C. (2008). El Concreto Masivo. Ciudad de Mexico: PROGRAMA DE MAESTRÍA Y DOCTORADO EN INGENIERÍA. Ramírez, L. C. (Enero de 2008). El Concreto Masivo. Ciudad de Mexico: PROGRAMA DE MAESTRÍA Y DOCTORADO EN INGENIERÍA. Reglamento colombiano de construcción sismorresistente NSR10 decreto 926 de marzo 19 de 2010. Rhodes, J. A. (1978). Propiedades térmicas: Importancia de las pruebas y propiedades del hormigón y materiales para la fabricación de hormigón. STP-169B, ASTM International, West Conshohocken, Pa., 242-266. Roa Rodríguez, G., Aperador Chaparro, W., & Delgado Tobón, E. (2015). Diseño de sistema de monitoreo remoto para evaluación de la corrosión en estructuras de concreto reforzado sometidas a ion cloruro. Ingeniería Investigación y Tecnología, Vol. XVI N° 4, 565-572. Ruiz Guerrero, J. (Junio de 2011). Repositorio Tec . Obtenido de Repositorio Institucional del Tecnológico de Costa Rica: https://repositoriotec.tec.ac.cr/handle/2238/6791 Sima, F., & Knut, S. (2014). Evolución de los Puentes Atirantados. FIRST INTERNATIONAL BRIDGES CONFERENCE - CHILE 2014, FUTURE CHALLENGES: DESIGN, CONSTRUCTION AND MAINTENANCE, (págs. 1-8). Santiago - CHILE. Obtenido de https://www.researchgate.net/profile/Fernando_Sima/publication/315825341_Evolucion_de_los_Puentes_Atirantados/links/58e8f4c4aca2729d8cd2acee/Evolucion-de-los-Puentes-Atirantados.pdf Solet Salamero, G. (2012, Febrero). Tesis: Puentes de Fortuna. Universidad Politécnica de Catalunya. Solis Carcaño, R., & I. Moreno, E. (2005). Influencia del curado húmedo en la resistencia a compresión del concreto en clima cálido subhúmedo. Ingenieria 9-3, 5-17. Solís Carcaño, R., & Moreno, E. I. (2006). Análisis de la porosidad del concreto con agregado calizo. Revista de la Facultad de Ingeniería de la U.C.V., Vol. 21, N° 3, 57-68. Toirac Corral, J. (2004). Patología de la construcción. Grietas y Fisuras en obras de Hormigón. Origen y Prevención. . Ciencia y Sociedad. Vol. XXIX, N°1, 72-114. Varona, F. B., Baena, F. J., & Ivorra, S. (2017). Estudio de las propiedades mecánicas residuales de hormigones expuestos a altas temperaturas. Hormigón y Acero, 1-7.PublicationORIGINALEVALUACIÓN TERMODINÁMICA DE LAS ESTRUCTURAS DE CONCRETO MASIVO ESTUDIO DEL NUEVO PUENTE PUMAREJO.pdfEVALUACIÓN TERMODINÁMICA DE LAS ESTRUCTURAS DE CONCRETO MASIVO ESTUDIO DEL NUEVO PUENTE PUMAREJO.pdfapplication/pdf4062324https://repositorio.cuc.edu.co/bitstreams/2cbce097-fb9a-48cc-a207-f18812ba86e7/download31d6313aed2d494a1b7f51e26217e894MD51CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-81031https://repositorio.cuc.edu.co/bitstreams/de847fb7-3a1a-42d2-9127-e7faa39c337e/download934f4ca17e109e0a05eaeaba504d7ce4MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.cuc.edu.co/bitstreams/89bb0d1d-f0f4-4183-8480-ee050007a7c4/download8a4605be74aa9ea9d79846c1fba20a33MD53THUMBNAILEVALUACIÓN TERMODINÁMICA DE LAS ESTRUCTURAS DE CONCRETO MASIVO ESTUDIO DEL NUEVO PUENTE PUMAREJO.pdf.jpgEVALUACIÓN TERMODINÁMICA DE LAS ESTRUCTURAS DE CONCRETO MASIVO ESTUDIO DEL NUEVO PUENTE PUMAREJO.pdf.jpgimage/jpeg29146https://repositorio.cuc.edu.co/bitstreams/106409fd-02af-412b-badd-edf81d70f012/downloadb721b14f6bc08b595cb1be6e46774ca9MD55TEXTEVALUACIÓN TERMODINÁMICA DE LAS ESTRUCTURAS DE CONCRETO MASIVO ESTUDIO DEL NUEVO PUENTE PUMAREJO.pdf.txtEVALUACIÓN TERMODINÁMICA DE LAS ESTRUCTURAS DE CONCRETO MASIVO ESTUDIO DEL NUEVO PUENTE PUMAREJO.pdf.txttext/plain147601https://repositorio.cuc.edu.co/bitstreams/00182f29-fc54-4ddb-9960-328830850907/downloade2b17fb31011a40daac0d9af8aad7679MD5611323/4918oai:repositorio.cuc.edu.co:11323/49182024-09-17 14:24:18.827http://creativecommons.org/licenses/by-nc-sa/4.0/Attribution-NonCommercial-ShareAlike 4.0 Internationalopen.accesshttps://repositorio.cuc.edu.coRepositorio de la Universidad de la Costa CUCrepdigital@cuc.edu.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