Continuous glucose monitoring in insulin-treated patients in non-ICU settings

Q1

Autores:
Gómez Gómez, Ana María
Umpierrez, Guillermo
Tipo de recurso:
Article of journal
Fecha de publicación:
2014
Institución:
Pontificia Universidad Javeriana
Repositorio:
Repositorio Universidad Javeriana
Idioma:
eng
OAI Identifier:
oai:repository.javeriana.edu.co:10554/52996
Acceso en línea:
https://journals.sagepub.com/doi/10.1177/1932296814546025?url_ver=Z39.88-2003&rfr_id=ori:rid:crossref.org&rfr_dat=cr_pub%20%200pubmed
http://hdl.handle.net/10554/52996
https://doi.org/10.1177/1932296814546025
Palabra clave:
Continuous glucose monitoring
Inpatient hyperglycemia
Point of care testing
Glucose monitoring
Rights
License
Atribución-NoComercial 4.0 Internacional
id JAVERIANA2_e97aff0189a4e9fa1e3775d5fffd3f0b
oai_identifier_str oai:repository.javeriana.edu.co:10554/52996
network_acronym_str JAVERIANA2
network_name_str Repositorio Universidad Javeriana
repository_id_str
spelling Atribución-NoComercial 4.0 Internacionalhttp://creativecommons.org/licenses/by-nc/4.0/http://purl.org/coar/access_right/c_abf2Gómez Gómez, Ana MaríaUmpierrez, GuillermoPontificia Universidad Javeriana. Facultad de Medicina. Departamento de Medicina Interna. Grupo de Investigación de Enfermedades Crónicas del AdultoPontificia Universidad Javeriana. Facultad de Medicina. Departamento de Endocrinología2021-02-17T20:29:47Z2021-02-17T20:29:47Z2014-09-01https://journals.sagepub.com/doi/10.1177/1932296814546025?url_ver=Z39.88-2003&rfr_id=ori:rid:crossref.org&rfr_dat=cr_pub%20%200pubmed1932-2968http://hdl.handle.net/10554/52996https://doi.org/10.1177/1932296814546025instname:Pontificia Universidad Javerianareponame:Repositorio Institucional - Pontificia Universidad Javerianarepourl:https://repository.javeriana.edu.coPDFapplication/pdfengContinuous glucose monitoring in insulin-treated patients in non-ICU settingsArtículo de revistahttp://purl.org/coar/resource_type/c_6501Q1Inpatient hyperglycemia, in patients with and without a history of diabetes, is associated with increased risk of complications, mortality, and longer hospital stay in medicine and surgical patients. Bedside capillary point of care testing is widely recommended as the preferred method for glucose monitoring and for guiding glycemic management of individual patients; however, the accuracy of most handheld glucose meters is far from optimal. Recent studies in the hospital setting have reported that the use of continuous glucose monitoring (CGM) can provide real-time information about glucose concentration, direction, and rate of change over a period of several days. Because it provides glucose values every 5-10 minutes 24 hours a day, CGM may have an advantage over point of care testing with respect to reducing the incidence of severe hypoglycemia in acute care. Real-time CGM technology may facilitate glycemic control and to reduce hypoglycemia in insulin-treated patients. Recent guidelines, however, have recommended deferring the use of CGM in the adult hospital setting until further data on accuracy and safety become available. In this study, we review the advantages and disadvantages of the use of real-time CGM in the management of dysglycemia in the hospital setting.https://orcid.org/0000-0002-1694-2479Continuous glucose monitoringInpatient hyperglycemiaPoint of care testingGlucose monitoring930936Journal of Diabetes Science and Technology85ORIGINALArtículo.pdfArtículo.pdfArtículoapplication/pdf470681http://repository.javeriana.edu.co/bitstream/10554/52996/1/Art%c3%adculo.pdf985d3a5084447e31103c5bd2d15bdef6MD51open accessLICENSElicense.txtlicense.txttext/plain; charset=utf-82603http://repository.javeriana.edu.co/bitstream/10554/52996/2/license.txt2070d280cc89439d983d9eee1b17df53MD52embargoed access|||9999-02-15THUMBNAILArtículo.pdf.jpgArtículo.pdf.jpgIM Thumbnailimage/jpeg9563http://repository.javeriana.edu.co/bitstream/10554/52996/3/Art%c3%adculo.pdf.jpg8e3170d82b6e025eb20422368d771b7bMD53open access10554/52996oai:repository.javeriana.edu.co:10554/529962021-03-30 20:39:53.574Repositorio Institucional - Pontificia Universidad Javerianarepositorio@javeriana.edu.co
dc.title.spa.fl_str_mv Continuous glucose monitoring in insulin-treated patients in non-ICU settings
title Continuous glucose monitoring in insulin-treated patients in non-ICU settings
spellingShingle Continuous glucose monitoring in insulin-treated patients in non-ICU settings
Continuous glucose monitoring
Inpatient hyperglycemia
Point of care testing
Glucose monitoring
title_short Continuous glucose monitoring in insulin-treated patients in non-ICU settings
title_full Continuous glucose monitoring in insulin-treated patients in non-ICU settings
title_fullStr Continuous glucose monitoring in insulin-treated patients in non-ICU settings
title_full_unstemmed Continuous glucose monitoring in insulin-treated patients in non-ICU settings
title_sort Continuous glucose monitoring in insulin-treated patients in non-ICU settings
dc.creator.fl_str_mv Gómez Gómez, Ana María
Umpierrez, Guillermo
dc.contributor.author.none.fl_str_mv Gómez Gómez, Ana María
Umpierrez, Guillermo
dc.contributor.corporatename.none.fl_str_mv Pontificia Universidad Javeriana. Facultad de Medicina. Departamento de Medicina Interna. Grupo de Investigación de Enfermedades Crónicas del Adulto
Pontificia Universidad Javeriana. Facultad de Medicina. Departamento de Endocrinología
dc.subject.keyword.spa.fl_str_mv Continuous glucose monitoring
Inpatient hyperglycemia
Point of care testing
Glucose monitoring
topic Continuous glucose monitoring
Inpatient hyperglycemia
Point of care testing
Glucose monitoring
description Q1
publishDate 2014
dc.date.created.none.fl_str_mv 2014-09-01
dc.date.accessioned.none.fl_str_mv 2021-02-17T20:29:47Z
dc.date.available.none.fl_str_mv 2021-02-17T20:29:47Z
dc.type.local.spa.fl_str_mv Artículo de revista
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
format http://purl.org/coar/resource_type/c_6501
dc.identifier.spa.fl_str_mv https://journals.sagepub.com/doi/10.1177/1932296814546025?url_ver=Z39.88-2003&rfr_id=ori:rid:crossref.org&rfr_dat=cr_pub%20%200pubmed
dc.identifier.issn.spa.fl_str_mv 1932-2968
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/10554/52996
dc.identifier.doi.spa.fl_str_mv https://doi.org/10.1177/1932296814546025
dc.identifier.instname.spa.fl_str_mv instname:Pontificia Universidad Javeriana
dc.identifier.reponame.spa.fl_str_mv reponame:Repositorio Institucional - Pontificia Universidad Javeriana
dc.identifier.repourl.spa.fl_str_mv repourl:https://repository.javeriana.edu.co
url https://journals.sagepub.com/doi/10.1177/1932296814546025?url_ver=Z39.88-2003&rfr_id=ori:rid:crossref.org&rfr_dat=cr_pub%20%200pubmed
http://hdl.handle.net/10554/52996
https://doi.org/10.1177/1932296814546025
identifier_str_mv 1932-2968
instname:Pontificia Universidad Javeriana
reponame:Repositorio Institucional - Pontificia Universidad Javeriana
repourl:https://repository.javeriana.edu.co
dc.language.iso.spa.fl_str_mv eng
language eng
dc.relation.citationstartpage.spa.fl_str_mv 930
dc.relation.citationendpage.spa.fl_str_mv 936
dc.relation.ispartofjournal.spa.fl_str_mv Journal of Diabetes Science and Technology
dc.relation.citationvolume.spa.fl_str_mv 8
dc.relation.citationissue.spa.fl_str_mv 5
dc.rights.licence.*.fl_str_mv Atribución-NoComercial 4.0 Internacional
dc.rights.uri.*.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Atribución-NoComercial 4.0 Internacional
http://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
dc.format.spa.fl_str_mv PDF
dc.format.mimetype.spa.fl_str_mv application/pdf
institution Pontificia Universidad Javeriana
bitstream.url.fl_str_mv http://repository.javeriana.edu.co/bitstream/10554/52996/1/Art%c3%adculo.pdf
http://repository.javeriana.edu.co/bitstream/10554/52996/2/license.txt
http://repository.javeriana.edu.co/bitstream/10554/52996/3/Art%c3%adculo.pdf.jpg
bitstream.checksum.fl_str_mv 985d3a5084447e31103c5bd2d15bdef6
2070d280cc89439d983d9eee1b17df53
8e3170d82b6e025eb20422368d771b7b
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional - Pontificia Universidad Javeriana
repository.mail.fl_str_mv repositorio@javeriana.edu.co
_version_ 1811671289595691008