Validation of three viable-cell counting methods: Manual, semi-automated, and automated
A viable cell count is essential to evaluate the kinetics of cell growth. Since the hemocytometer was first used for counting blood cells, several variants of the methodology have been developed towards reducing the time of analysis and improving accuracy through automation of both sample preparatio...
- Autores:
-
Cadena-Herrera, Daniela
Medina-Rivero, Emilio
Flores-Ortiz, Luis F.
Pérez, Néstor O.
López-Morales, Carlos A.
Ramírez-Ibañez, Nancy D.
Esparza-De Lara, Joshua E.
- Tipo de recurso:
- Article of investigation
- Fecha de publicación:
- 2015
- Institución:
- Universidad ICESI
- Repositorio:
- Repositorio ICESI
- Idioma:
- eng
- OAI Identifier:
- oai:repository.icesi.edu.co:10906/79910
- Acceso en línea:
- http://www.sciencedirect.com/science/article/pii/S2215017X15000235
http://hdl.handle.net/10906/79910
http://dx.doi.org/10.1016/j.btre.2015.04.004
- Palabra clave:
- Rights
- openAccess
- License
- https://creativecommons.org/licenses/by-nc-nd/4.0/
id |
ICESI2_5e627b3d83b179063895c45e97ecd6ea |
---|---|
oai_identifier_str |
oai:repository.icesi.edu.co:10906/79910 |
network_acronym_str |
ICESI2 |
network_name_str |
Repositorio ICESI |
repository_id_str |
|
spelling |
Cadena-Herrera, DanielaMedina-Rivero, EmilioFlores-Ortiz, Luis F.Pérez, Néstor O.López-Morales, Carlos A.Ramírez-Ibañez, Nancy D.Esparza-De Lara, Joshua E.2016-08-30T22:02:03Z2016-08-30T22:02:03Z2015-09-012215-017Xhttp://www.sciencedirect.com/science/article/pii/S2215017X15000235http://hdl.handle.net/10906/79910http://dx.doi.org/10.1016/j.btre.2015.04.004instname: Universidad Icesireponame: Biblioteca Digitalrepourl: https://repository.icesi.edu.co/A viable cell count is essential to evaluate the kinetics of cell growth. Since the hemocytometer was first used for counting blood cells, several variants of the methodology have been developed towards reducing the time of analysis and improving accuracy through automation of both sample preparation and counting. The successful implementation of automated techniques relies in the adjustment of cell staining, image display parameters and cell morphology to obtain equivalent precision, accuracy and linearity with respect to the hemocytometer. In this study we conducted the validation of three trypan blue exclusion-based methods: manual, semi-automated, and fully automated; which were used for the estimation of density and viability of cells employed for the biosynthesis and bioassays of recombinant proteins. Our results showed that the evaluated attributes remained within the same range for the automated methods with respect to the manual, providing an efficient alternative for analyzing a huge number of samples.Digitalapplication/pdfengElsevierFacultad de Ciencias NaturalesBiotechnology Reports, Vol. 7 - 2015EL AUTOR, expresa que la obra objeto de la presente autorización es original y la elaboró sin quebrantar ni suplantar los derechos de autor de terceros, y de tal forma, la obra es de su exclusiva autoría y tiene la titularidad sobre éste. PARÁGRAFO: en caso de queja o acción por parte de un tercero referente a los derechos de autor sobre el artículo, folleto o libro en cuestión, EL AUTOR, asumirá la responsabilidad total, y saldrá en defensa de los derechos aquí autorizados; para todos los efectos, la Universidad Icesi actúa como un tercero de buena fe. Esta autorización, permite a la Universidad Icesi, de forma indefinida, para que en los términos establecidos en la Ley 23 de 1982, la Ley 44 de 1993, leyes y jurisprudencia vigente al respecto, haga publicación de este con fines educativos. Toda persona que consulte ya sea la biblioteca o en medio electrónico podrá copiar apartes del texto citando siempre la fuentes, es decir el título del trabajo y el autor.https://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)http://purl.org/coar/access_right/c_abf2Validation of three viable-cell counting methods: Manual, semi-automated, and automatedinfo:eu-repo/semantics/articlehttp://purl.org/coar/resource_type/c_2df8fbb1Artículoinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/version/c_970fb48d4fbd8a85Comunidad Universidad Icesi – Investigadores7916ORIGINALDocumento.htmlDocumento.htmltext/html281http://repository.icesi.edu.co/biblioteca_digital/bitstream/10906/79910/1/Documento.htmlda9f58be92c56b7249b243ede3bc2bf8MD5110906/79910oai:repository.icesi.edu.co:10906/799102020-05-18 16:48:04.169Biblioteca Digital - Universidad icesicdcriollo@icesi.edu.co |
dc.title.eng.fl_str_mv |
Validation of three viable-cell counting methods: Manual, semi-automated, and automated |
title |
Validation of three viable-cell counting methods: Manual, semi-automated, and automated |
spellingShingle |
Validation of three viable-cell counting methods: Manual, semi-automated, and automated |
title_short |
Validation of three viable-cell counting methods: Manual, semi-automated, and automated |
title_full |
Validation of three viable-cell counting methods: Manual, semi-automated, and automated |
title_fullStr |
Validation of three viable-cell counting methods: Manual, semi-automated, and automated |
title_full_unstemmed |
Validation of three viable-cell counting methods: Manual, semi-automated, and automated |
title_sort |
Validation of three viable-cell counting methods: Manual, semi-automated, and automated |
dc.creator.fl_str_mv |
Cadena-Herrera, Daniela Medina-Rivero, Emilio Flores-Ortiz, Luis F. Pérez, Néstor O. López-Morales, Carlos A. Ramírez-Ibañez, Nancy D. Esparza-De Lara, Joshua E. |
dc.contributor.author.spa.fl_str_mv |
Cadena-Herrera, Daniela Medina-Rivero, Emilio Flores-Ortiz, Luis F. Pérez, Néstor O. López-Morales, Carlos A. Ramírez-Ibañez, Nancy D. Esparza-De Lara, Joshua E. |
description |
A viable cell count is essential to evaluate the kinetics of cell growth. Since the hemocytometer was first used for counting blood cells, several variants of the methodology have been developed towards reducing the time of analysis and improving accuracy through automation of both sample preparation and counting. The successful implementation of automated techniques relies in the adjustment of cell staining, image display parameters and cell morphology to obtain equivalent precision, accuracy and linearity with respect to the hemocytometer. In this study we conducted the validation of three trypan blue exclusion-based methods: manual, semi-automated, and fully automated; which were used for the estimation of density and viability of cells employed for the biosynthesis and bioassays of recombinant proteins. Our results showed that the evaluated attributes remained within the same range for the automated methods with respect to the manual, providing an efficient alternative for analyzing a huge number of samples. |
publishDate |
2015 |
dc.date.issued.none.fl_str_mv |
2015-09-01 |
dc.date.accessioned.none.fl_str_mv |
2016-08-30T22:02:03Z |
dc.date.available.none.fl_str_mv |
2016-08-30T22:02:03Z |
dc.type.eng.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.coar.none.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.local.spa.fl_str_mv |
Artículo |
dc.type.version.eng.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coarversion.none.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
format |
http://purl.org/coar/resource_type/c_2df8fbb1 |
status_str |
publishedVersion |
dc.identifier.issn.none.fl_str_mv |
2215-017X |
dc.identifier.other.spa.fl_str_mv |
http://www.sciencedirect.com/science/article/pii/S2215017X15000235 |
dc.identifier.uri.eng.fl_str_mv |
http://hdl.handle.net/10906/79910 |
dc.identifier.doi.none.fl_str_mv |
http://dx.doi.org/10.1016/j.btre.2015.04.004 |
dc.identifier.instname.none.fl_str_mv |
instname: Universidad Icesi |
dc.identifier.reponame.none.fl_str_mv |
reponame: Biblioteca Digital |
dc.identifier.repourl.none.fl_str_mv |
repourl: https://repository.icesi.edu.co/ |
identifier_str_mv |
2215-017X instname: Universidad Icesi reponame: Biblioteca Digital repourl: https://repository.icesi.edu.co/ |
url |
http://www.sciencedirect.com/science/article/pii/S2215017X15000235 http://hdl.handle.net/10906/79910 http://dx.doi.org/10.1016/j.btre.2015.04.004 |
dc.language.iso.eng.fl_str_mv |
eng |
language |
eng |
dc.relation.ispartof.eng.fl_str_mv |
Biotechnology Reports, Vol. 7 - 2015 |
dc.rights.uri.none.fl_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0/ |
dc.rights.accessrights.eng.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.license.none.fl_str_mv |
Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) |
dc.rights.coar.none.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0/ Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.medium.spa.fl_str_mv |
Digital |
dc.format.mimetype.eng.fl_str_mv |
application/pdf |
dc.publisher.eng.fl_str_mv |
Elsevier |
dc.publisher.faculty.spa.fl_str_mv |
Facultad de Ciencias Naturales |
institution |
Universidad ICESI |
bitstream.url.fl_str_mv |
http://repository.icesi.edu.co/biblioteca_digital/bitstream/10906/79910/1/Documento.html |
bitstream.checksum.fl_str_mv |
da9f58be92c56b7249b243ede3bc2bf8 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 |
repository.name.fl_str_mv |
Biblioteca Digital - Universidad icesi |
repository.mail.fl_str_mv |
cdcriollo@icesi.edu.co |
_version_ |
1814094868491796480 |