Análisis de los parámetros de diseño para un edificio con y sin aisladores en la base.

One of the great problems that arises in the Construction is the seismic response of a structure in the presence of an earthquake, usually for the design the seismic norms that ensure the safety of people are taken into account; however, the state in which the structure remains once the earthquake o...

Full description

Autores:
Gordillo Piñeros, Sinthya Julieth
Fragozo Zarate, Juana Lucía
Tipo de recurso:
Trabajo de grado de pregrado
Fecha de publicación:
2019
Institución:
Escuela Colombiana de Ingeniería Julio Garavito
Repositorio:
Repositorio Institucional ECI
Idioma:
spa
OAI Identifier:
oai:repositorio.escuelaing.edu.co:001/1053
Acceso en línea:
https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=22251
https://repositorio.escuelaing.edu.co/handle/001/1053
Palabra clave:
Diseño estructural
Estructuras en Concreto
Aisladores
Structural Design
Concrete structures
Isolator
Rights
closedAccess
License
Derechos Reservados - Escuela Colombiana de Ingeniería Julio Garavito
id ESCUELAIG2_97d2761fab9df8567357dc5f8cbf60fa
oai_identifier_str oai:repositorio.escuelaing.edu.co:001/1053
network_acronym_str ESCUELAIG2
network_name_str Repositorio Institucional ECI
repository_id_str
dc.title.spa.fl_str_mv Análisis de los parámetros de diseño para un edificio con y sin aisladores en la base.
title Análisis de los parámetros de diseño para un edificio con y sin aisladores en la base.
spellingShingle Análisis de los parámetros de diseño para un edificio con y sin aisladores en la base.
Diseño estructural
Estructuras en Concreto
Aisladores
Structural Design
Concrete structures
Isolator
title_short Análisis de los parámetros de diseño para un edificio con y sin aisladores en la base.
title_full Análisis de los parámetros de diseño para un edificio con y sin aisladores en la base.
title_fullStr Análisis de los parámetros de diseño para un edificio con y sin aisladores en la base.
title_full_unstemmed Análisis de los parámetros de diseño para un edificio con y sin aisladores en la base.
title_sort Análisis de los parámetros de diseño para un edificio con y sin aisladores en la base.
dc.creator.fl_str_mv Gordillo Piñeros, Sinthya Julieth
Fragozo Zarate, Juana Lucía
dc.contributor.advisor.spa.fl_str_mv Jerez Barbosa, Sandra Rocío (dir)
dc.contributor.author.spa.fl_str_mv Gordillo Piñeros, Sinthya Julieth
Fragozo Zarate, Juana Lucía
dc.subject.spa.fl_str_mv Diseño estructural
Estructuras en Concreto
Aisladores
topic Diseño estructural
Estructuras en Concreto
Aisladores
Structural Design
Concrete structures
Isolator
dc.subject.keywords.spa.fl_str_mv Structural Design
Concrete structures
Isolator
description One of the great problems that arises in the Construction is the seismic response of a structure in the presence of an earthquake, usually for the design the seismic norms that ensure the safety of people are taken into account; however, the state in which the structure remains once the earthquake occurs is not taken into account. In this work an analysis was made of the parameters necessary for the design of a building with and without insulators, showing the advantages and disadvantages of the presence of these devices that will improve the seismic response of a building.
publishDate 2019
dc.date.issued.spa.fl_str_mv 2019
dc.date.accessioned.spa.fl_str_mv 2020-01-30T20:48:41Z
dc.date.available.spa.fl_str_mv 2020-01-30T20:48:41Z
dc.date.accessioned.none.fl_str_mv 2021-10-01T14:33:20Z
dc.date.available.none.fl_str_mv 2021-10-01T14:33:20Z
dc.type.spa.fl_str_mv Trabajo de grado - Pregrado
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_7a1f
dc.type.content.spa.fl_str_mv Text
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/bachelorThesis
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/TP
format http://purl.org/coar/resource_type/c_7a1f
status_str publishedVersion
dc.identifier.uri.spa.fl_str_mv https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=22251
dc.identifier.uri.none.fl_str_mv https://repositorio.escuelaing.edu.co/handle/001/1053
url https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=22251
https://repositorio.escuelaing.edu.co/handle/001/1053
dc.language.iso.spa.fl_str_mv spa
language spa
dc.rights.spa.fl_str_mv Derechos Reservados - Escuela Colombiana de Ingeniería Julio Garavito
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_14cb
dc.rights.uri.spa.fl_str_mv https://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/closedAccess
dc.rights.creativecommons.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)
rights_invalid_str_mv Derechos Reservados - Escuela Colombiana de Ingeniería Julio Garavito
https://creativecommons.org/licenses/by-nc/4.0/
Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)
http://purl.org/coar/access_right/c_14cb
eu_rights_str_mv closedAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Escuela Colombiana de Ingeniería Julio Garavito
dc.publisher.program.spa.fl_str_mv Ingeniería Civil
institution Escuela Colombiana de Ingeniería Julio Garavito
bitstream.url.fl_str_mv https://repositorio.escuelaing.edu.co/bitstream/001/1053/1/Gordillo%20Pi%c3%b1eros%2c%20Sinthya%20Julieth-2019.pdf
https://repositorio.escuelaing.edu.co/bitstream/001/1053/2/Autorizaci%c3%b3n.pdf
https://repositorio.escuelaing.edu.co/bitstream/001/1053/3/license.txt
https://repositorio.escuelaing.edu.co/bitstream/001/1053/6/Gordillo%20Pi%c3%b1eros%2c%20Sinthya%20Julieth-2019.pdf.txt
https://repositorio.escuelaing.edu.co/bitstream/001/1053/8/Autorizaci%c3%b3n.pdf.txt
https://repositorio.escuelaing.edu.co/bitstream/001/1053/7/Gordillo%20Pi%c3%b1eros%2c%20Sinthya%20Julieth-2019.pdf.jpg
https://repositorio.escuelaing.edu.co/bitstream/001/1053/9/Autorizaci%c3%b3n.pdf.jpg
bitstream.checksum.fl_str_mv 9332fa97e20d00921ef3129adb684553
6d2ab96654609653df1cf3e98d03ba07
5a7ca94c2e5326ee169f979d71d0f06e
415e43f2df8bdf9fec03f1114e964aa8
e1c06d85ae7b8b032bef47e42e4c08f9
2b2b94e85ff0d8097df8eba8b29f941b
d27991e1ceaf653caaabe3953d838f20
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Escuela Colombiana de Ingeniería Julio Garavito
repository.mail.fl_str_mv repositorio.eci@escuelaing.edu.co
_version_ 1814355622665125888
spelling Jerez Barbosa, Sandra Rocío (dir)c152e9ced3909a8460a2f24b8878e028300Gordillo Piñeros, Sinthya Juliethdbf098ba9319de161d80cea1257a5181600Fragozo Zarate, Juana Lucía0dca33369e31e049161961827ac80ea66002020-01-30T20:48:41Z2021-10-01T14:33:20Z2020-01-30T20:48:41Z2021-10-01T14:33:20Z2019https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=22251https://repositorio.escuelaing.edu.co/handle/001/1053One of the great problems that arises in the Construction is the seismic response of a structure in the presence of an earthquake, usually for the design the seismic norms that ensure the safety of people are taken into account; however, the state in which the structure remains once the earthquake occurs is not taken into account. In this work an analysis was made of the parameters necessary for the design of a building with and without insulators, showing the advantages and disadvantages of the presence of these devices that will improve the seismic response of a building.Una de las grandes problemáticas que se presenta en la Construcción es la respuesta sísmica de una estructura ante la presencia de un terremoto, por lo general para el diseño se tienen en cuenta las normas sísmicas que velan por la seguridad de las personas; sin embargo, no se tiene en cuenta el estado en que queda la estructura una vez se presenta el terremoto. En este trabajo se hizo un análisis de los parámetros necesarios para el diseño de un edificio con y sin aisladores, mostrando las ventajas y desventajas de la presencia de estos dispositivos que mejoran significativamente la respuesta sísmica de un edificio.PregradoIngeniero(a) Civilapplication/pdfspaEscuela Colombiana de Ingeniería Julio GaravitoIngeniería CivilDerechos Reservados - Escuela Colombiana de Ingeniería Julio Garavitohttps://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/closedAccessAtribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)http://purl.org/coar/access_right/c_14cbDiseño estructuralEstructuras en ConcretoAisladoresStructural DesignConcrete structuresIsolatorAnálisis de los parámetros de diseño para un edificio con y sin aisladores en la base.Trabajo de grado - Pregradoinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_7a1fTextinfo:eu-repo/semantics/bachelorThesishttp://purl.org/redcol/resource_type/TPhttp://purl.org/coar/version/c_970fb48d4fbd8a85ORIGINALGordillo Piñeros, Sinthya Julieth-2019.pdfapplication/pdf2760516https://repositorio.escuelaing.edu.co/bitstream/001/1053/1/Gordillo%20Pi%c3%b1eros%2c%20Sinthya%20Julieth-2019.pdf9332fa97e20d00921ef3129adb684553MD51open accessAutorización.pdfapplication/pdf32106774https://repositorio.escuelaing.edu.co/bitstream/001/1053/2/Autorizaci%c3%b3n.pdf6d2ab96654609653df1cf3e98d03ba07MD52metadata only accessLICENSElicense.txttext/plain1881https://repositorio.escuelaing.edu.co/bitstream/001/1053/3/license.txt5a7ca94c2e5326ee169f979d71d0f06eMD53open accessTEXTGordillo Piñeros, Sinthya Julieth-2019.pdf.txtGordillo Piñeros, Sinthya Julieth-2019.pdf.txtExtracted texttext/plain109806https://repositorio.escuelaing.edu.co/bitstream/001/1053/6/Gordillo%20Pi%c3%b1eros%2c%20Sinthya%20Julieth-2019.pdf.txt415e43f2df8bdf9fec03f1114e964aa8MD56open accessAutorización.pdf.txtAutorización.pdf.txtExtracted texttext/plain2https://repositorio.escuelaing.edu.co/bitstream/001/1053/8/Autorizaci%c3%b3n.pdf.txte1c06d85ae7b8b032bef47e42e4c08f9MD58metadata only accessTHUMBNAILGordillo Piñeros, Sinthya Julieth-2019.pdf.jpgGordillo Piñeros, Sinthya Julieth-2019.pdf.jpgGenerated Thumbnailimage/jpeg7060https://repositorio.escuelaing.edu.co/bitstream/001/1053/7/Gordillo%20Pi%c3%b1eros%2c%20Sinthya%20Julieth-2019.pdf.jpg2b2b94e85ff0d8097df8eba8b29f941bMD57open accessAutorización.pdf.jpgAutorización.pdf.jpgGenerated Thumbnailimage/jpeg12587https://repositorio.escuelaing.edu.co/bitstream/001/1053/9/Autorizaci%c3%b3n.pdf.jpgd27991e1ceaf653caaabe3953d838f20MD59metadata only access001/1053oai:repositorio.escuelaing.edu.co:001/10532021-10-01 17:17:50.548open accessRepositorio Escuela Colombiana de Ingeniería Julio Garavitorepositorio.eci@escuelaing.edu.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