Eficiencia de desinfección en piscinas de clima tropical: caso de estudio parque acuático piscilago, girardot - Colombia.

This research is based on the comparison of the effectiveness of the three disinfection methods used in the pools of the Mega Park (Chlorine, Ozone and UV Radiation); by means of the characterization of the water of a total of ten (10) pools, taking into account the physicochemical and microbiologic...

Full description

Autores:
Vega Romero, Diana Carolina
Tipo de recurso:
Fecha de publicación:
2018
Institución:
Escuela Colombiana de Ingeniería Julio Garavito
Repositorio:
Repositorio Institucional ECI
Idioma:
spa
OAI Identifier:
oai:repositorio.escuelaing.edu.co:001/935
Acceso en línea:
https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=21790https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=21790
https://repositorio.escuelaing.edu.co/handle/001/935
Palabra clave:
Piscinas
Desinfecciónes de aguas
Cloro residual
Eficiencia
Coliformes Totales
Calidad del agua
Swimming Pools
Disinfection
Residual Chlorine
Efficiency
Total Coliforms
Water quality
Rights
openAccess
License
Derechos Reservados - Escuela Colombiana de Ingeniería Julio Garavito
id ESCUELAIG2_3bad617194b2c82f0af1d3bab4323d1b
oai_identifier_str oai:repositorio.escuelaing.edu.co:001/935
network_acronym_str ESCUELAIG2
network_name_str Repositorio Institucional ECI
repository_id_str
dc.title.spa.fl_str_mv Eficiencia de desinfección en piscinas de clima tropical: caso de estudio parque acuático piscilago, girardot - Colombia.
title Eficiencia de desinfección en piscinas de clima tropical: caso de estudio parque acuático piscilago, girardot - Colombia.
spellingShingle Eficiencia de desinfección en piscinas de clima tropical: caso de estudio parque acuático piscilago, girardot - Colombia.
Piscinas
Desinfecciónes de aguas
Cloro residual
Eficiencia
Coliformes Totales
Calidad del agua
Swimming Pools
Disinfection
Residual Chlorine
Efficiency
Total Coliforms
Water quality
title_short Eficiencia de desinfección en piscinas de clima tropical: caso de estudio parque acuático piscilago, girardot - Colombia.
title_full Eficiencia de desinfección en piscinas de clima tropical: caso de estudio parque acuático piscilago, girardot - Colombia.
title_fullStr Eficiencia de desinfección en piscinas de clima tropical: caso de estudio parque acuático piscilago, girardot - Colombia.
title_full_unstemmed Eficiencia de desinfección en piscinas de clima tropical: caso de estudio parque acuático piscilago, girardot - Colombia.
title_sort Eficiencia de desinfección en piscinas de clima tropical: caso de estudio parque acuático piscilago, girardot - Colombia.
dc.creator.fl_str_mv Vega Romero, Diana Carolina
dc.contributor.advisor.spa.fl_str_mv Sánchez Londoño, Yuly Andrea (dir)
dc.contributor.author.spa.fl_str_mv Vega Romero, Diana Carolina
dc.subject.spa.fl_str_mv Piscinas
Desinfecciónes de aguas
Cloro residual
Eficiencia
Coliformes Totales
Calidad del agua
topic Piscinas
Desinfecciónes de aguas
Cloro residual
Eficiencia
Coliformes Totales
Calidad del agua
Swimming Pools
Disinfection
Residual Chlorine
Efficiency
Total Coliforms
Water quality
dc.subject.keywords.spa.fl_str_mv Swimming Pools
Disinfection
Residual Chlorine
Efficiency
Total Coliforms
Water quality
description This research is based on the comparison of the effectiveness of the three disinfection methods used in the pools of the Mega Park (Chlorine, Ozone and UV Radiation); by means of the characterization of the water of a total of ten (10) pools, taking into account the physicochemical and microbiological parameters; For this purpose, the samples taken by the Park between the months of August 2016 and December 2017 and two counter samplings in the months of June and September 2018, carried out by the researcher, are analysed in order to verify the pattern between the different dates and the influence of the season (high or low), defined by the affluence of the public and finally, to determine the main advantages and disadvantages of each method. However, chlorine, due to its molecular stability, continues to disinfect even after it has been applied. Therefore, ozone and UV radiation methods receive a minimum dose of chlorine to guarantee the residual effect; on the other hand, these processes are difficult to access due to their high cost of acquisition and operation, so they are only used in parks with the economic capacity to finance this type of treatment.
publishDate 2018
dc.date.issued.spa.fl_str_mv 2018
dc.date.accessioned.spa.fl_str_mv 2019-02-19T14:40:58Z
dc.date.available.spa.fl_str_mv 2019-02-19T14:40:58Z
dc.date.accessioned.none.fl_str_mv 2021-10-01T15:28:45Z
dc.date.available.none.fl_str_mv 2021-10-01T15:28:45Z
dc.type.spa.fl_str_mv Trabajo de grado - Maestría
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.content.spa.fl_str_mv Text
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/masterThesis
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/TM
status_str publishedVersion
dc.identifier.uri.spa.fl_str_mv https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=21790https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=21790
dc.identifier.uri.none.fl_str_mv https://repositorio.escuelaing.edu.co/handle/001/935
url https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=21790https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=21790
https://repositorio.escuelaing.edu.co/handle/001/935
dc.language.iso.spa.fl_str_mv spa
language spa
dc.rights.spa.fl_str_mv Derechos Reservados - Escuela Colombiana de Ingeniería Julio Garavito
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.uri.spa.fl_str_mv https://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.creativecommons.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)
rights_invalid_str_mv Derechos Reservados - Escuela Colombiana de Ingeniería Julio Garavito
https://creativecommons.org/licenses/by-nc/4.0/
Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Escuela Colombiana de Ingeniería
dc.publisher.program.spa.fl_str_mv Maestría en Ingeniería Civil con Énfasis en Ingeniería Ambiental
institution Escuela Colombiana de Ingeniería Julio Garavito
bitstream.url.fl_str_mv https://repositorio.escuelaing.edu.co/bitstream/001/935/1/Vega%20Romero%2c%20Diana%20Carolina%20-%202018.pdf
https://repositorio.escuelaing.edu.co/bitstream/001/935/2/Autorizaci%c3%b3n%20.pdf
https://repositorio.escuelaing.edu.co/bitstream/001/935/3/license.txt
https://repositorio.escuelaing.edu.co/bitstream/001/935/6/Vega%20Romero%2c%20Diana%20Carolina%20-%202018.pdf.txt
https://repositorio.escuelaing.edu.co/bitstream/001/935/8/Autorizaci%c3%b3n%20.pdf.txt
https://repositorio.escuelaing.edu.co/bitstream/001/935/7/Vega%20Romero%2c%20Diana%20Carolina%20-%202018.pdf.jpg
https://repositorio.escuelaing.edu.co/bitstream/001/935/9/Autorizaci%c3%b3n%20.pdf.jpg
bitstream.checksum.fl_str_mv 624a3dd2b6a3066f8a3dd2c5dbaccb41
f531ade12044c81b456d93dfbb7a1e35
5a7ca94c2e5326ee169f979d71d0f06e
e6a653c4e7ca021ecdfbfc704b8432e3
e1c06d85ae7b8b032bef47e42e4c08f9
a46a65dc505e7bcab17fc9499ca48ad7
09267c29e16bd799c6ca091226b71685
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Escuela Colombiana de Ingeniería Julio Garavito
repository.mail.fl_str_mv repositorio.eci@escuelaing.edu.co
_version_ 1814355580938092544
spelling Sánchez Londoño, Yuly Andrea (dir)d51fb39cd778414ca97162ca4f18cdf5500Vega Romero, Diana Carolina22575d51273ba67f6751d655842ae49b6002019-02-19T14:40:58Z2021-10-01T15:28:45Z2019-02-19T14:40:58Z2021-10-01T15:28:45Z2018https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=21790https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=21790https://repositorio.escuelaing.edu.co/handle/001/935This research is based on the comparison of the effectiveness of the three disinfection methods used in the pools of the Mega Park (Chlorine, Ozone and UV Radiation); by means of the characterization of the water of a total of ten (10) pools, taking into account the physicochemical and microbiological parameters; For this purpose, the samples taken by the Park between the months of August 2016 and December 2017 and two counter samplings in the months of June and September 2018, carried out by the researcher, are analysed in order to verify the pattern between the different dates and the influence of the season (high or low), defined by the affluence of the public and finally, to determine the main advantages and disadvantages of each method. However, chlorine, due to its molecular stability, continues to disinfect even after it has been applied. Therefore, ozone and UV radiation methods receive a minimum dose of chlorine to guarantee the residual effect; on the other hand, these processes are difficult to access due to their high cost of acquisition and operation, so they are only used in parks with the economic capacity to finance this type of treatment.Esta investigación se basa en la comparación de la efectividad de los tres métodos de desinfección usados en las piscinas del Mega Parque (Cloro, Ozono y Radiación UV); mediante la caracterización del agua de un total de diez (10) piscinas, tomando en cuenta los parámetros fisicoquímicos y microbiológicos; para ello, se analizan los muestreos tomados por el Parque entre los meses de agosto de 2016 y diciembre de 2017 y dos contra muestreos en los meses de junio y septiembre de 2018, realizados por la investigadora, de esta manera verificar el patrón entre las distintas fechas y la influencia de la temporada (alta o baja), definidas por la afluencia de público y por último, determinar las principales ventajas y desventajas de cada método. Luego de desarrollada la investigación se llega a la conclusión que todos los métodos de desinfección poseen una eficiencia similar, sin embargo, el cloro por su estabilidad molecular sigue desinfectando aun después de aplicado; por lo cual, a los métodos de ozono y radiación UV se les aplica una mínima dosis de cloro para garantizar el efecto residual; por otro lado, estos procesos son de difícil acceso a razón de su alto coste de adquisición y operatividad, por lo que solamente es usado en parques con la capacidad económica para financiar este tipo de tratamientos.MaestríaMagíster el Ingeniería Civil con Énfasis en Ingeniería Ambientalapplication/pdfspaEscuela Colombiana de IngenieríaMaestría en Ingeniería Civil con Énfasis en Ingeniería AmbientalDerechos Reservados - Escuela Colombiana de Ingeniería Julio Garavitohttps://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccessAtribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)http://purl.org/coar/access_right/c_abf2PiscinasDesinfecciónes de aguasCloro residualEficienciaColiformes TotalesCalidad del aguaSwimming PoolsDisinfectionResidual ChlorineEfficiencyTotal ColiformsWater qualityEficiencia de desinfección en piscinas de clima tropical: caso de estudio parque acuático piscilago, girardot - Colombia.Trabajo de grado - Maestríainfo:eu-repo/semantics/publishedVersionTextinfo:eu-repo/semantics/masterThesishttp://purl.org/redcol/resource_type/TMhttp://purl.org/coar/version/c_970fb48d4fbd8a85ORIGINALVega Romero, Diana Carolina - 2018.pdfapplication/pdf12977763https://repositorio.escuelaing.edu.co/bitstream/001/935/1/Vega%20Romero%2c%20Diana%20Carolina%20-%202018.pdf624a3dd2b6a3066f8a3dd2c5dbaccb41MD51open accessAutorización .pdfapplication/pdf216960https://repositorio.escuelaing.edu.co/bitstream/001/935/2/Autorizaci%c3%b3n%20.pdff531ade12044c81b456d93dfbb7a1e35MD52metadata only accessLICENSElicense.txttext/plain1881https://repositorio.escuelaing.edu.co/bitstream/001/935/3/license.txt5a7ca94c2e5326ee169f979d71d0f06eMD53open accessTEXTVega Romero, Diana Carolina - 2018.pdf.txtVega Romero, Diana Carolina - 2018.pdf.txtExtracted texttext/plain128966https://repositorio.escuelaing.edu.co/bitstream/001/935/6/Vega%20Romero%2c%20Diana%20Carolina%20-%202018.pdf.txte6a653c4e7ca021ecdfbfc704b8432e3MD56open accessAutorización .pdf.txtAutorización .pdf.txtExtracted texttext/plain2https://repositorio.escuelaing.edu.co/bitstream/001/935/8/Autorizaci%c3%b3n%20.pdf.txte1c06d85ae7b8b032bef47e42e4c08f9MD58metadata only accessTHUMBNAILVega Romero, Diana Carolina - 2018.pdf.jpgVega Romero, Diana Carolina - 2018.pdf.jpgGenerated Thumbnailimage/jpeg6079https://repositorio.escuelaing.edu.co/bitstream/001/935/7/Vega%20Romero%2c%20Diana%20Carolina%20-%202018.pdf.jpga46a65dc505e7bcab17fc9499ca48ad7MD57open accessAutorización .pdf.jpgAutorización .pdf.jpgGenerated Thumbnailimage/jpeg3598https://repositorio.escuelaing.edu.co/bitstream/001/935/9/Autorizaci%c3%b3n%20.pdf.jpg09267c29e16bd799c6ca091226b71685MD59metadata only access001/935oai:repositorio.escuelaing.edu.co:001/9352021-10-01 16:13:01.484open accessRepositorio Escuela Colombiana de Ingeniería Julio Garavitorepositorio.eci@escuelaing.edu.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