Sleeve for Knee Angle Monitoring: An IMU-POF Sensor Fusion System
The knee flexion-extension angle is an important variable to be monitored in various clinical scenarios, for example, during physical rehabilitation assessment. The purpose of this work is to develop and validate a sensor fusion system based on a knee sleeve for monitoring of physical therapy. The s...
- Autores:
-
Vargas Valencia, Laura Susana
Schneider, Felipe B. A.
Leal Junior, Arnaldo G.
Caicedo Rodríguez, Pablo
Sierra Arévalo, Wilson A.
Rodríguez Cheu, Luis E.
Bastos Filho, Teodiano
Frizera Neto, Anselmo
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2021
- Institución:
- Escuela Colombiana de Ingeniería Julio Garavito
- Repositorio:
- Repositorio Institucional ECI
- Idioma:
- eng
- OAI Identifier:
- oai:repositorio.escuelaing.edu.co:001/3321
- Acceso en línea:
- https://repositorio.escuelaing.edu.co/handle/001/3321
https://repositorio.escuelaing.edu.co/
- Palabra clave:
- Rehabilitación médica
Medical rehabilitation
Terapia ocupacional
Occupational therapy
Medicina física
Medicine, Physical
Aparatos fisiológicos
Physiological apparatus
Articulaciones - Rango de movimiento
Joints - Range of motion
Sensores inerciales
Ángulos articulares
Movimiento estimación
Fusión de sensores
Sistemas portátiles
Inertial sensors
Joint angles
motion estimation
POF
Sensor fusion
Wearable systems
- Rights
- closedAccess
- License
- http://purl.org/coar/access_right/c_14cb
Summary: | The knee flexion-extension angle is an important variable to be monitored in various clinical scenarios, for example, during physical rehabilitation assessment. The purpose of this work is to develop and validate a sensor fusion system based on a knee sleeve for monitoring of physical therapy. The system consists of merging data from two inertial measurement units (IMUs) and an intensityvariation based Polymer Optical Fiber (POF) curvature sensor using a quaternion-based Multiplicative Extended Kalman Filter (MEKF). The proposed data fusion method is magnetometer-free and deals with sensors’ uncertainties through reliability intervals defined during gait. Walking trials were performed by twelve healthy participants using our knee sleeve system and results were validated against a gold standard motion capture system. Additionally, a comparison with other three knee angle estimation methods, which are exclusively based on IMUs, was carried out. The proposed system presented better performance (mean RMSE < 3.3◦, LFM coefficients, a1 = 0.99 ± 0.04, a0 = 0.70 ± 2.29, R2 = 0.98 ± 0.01 and ρC > 0.99) when compared to the other evaluated methods. Experimental results demonstrate the usability and feasibility of our system to estimate knee motion with high accuracy, repeatability, and reproducibility. This wearable system may be suitable for motion assessment in rehabilitation labs in future studies. |
---|