Análisis del comportamiento de barras corrugadas de acero post-instaladas con adhesivo epóxico en concreto ligero sometidos a tensión y cortante :

In the country and in general in the world, the study of post-installed anchors has been limited to conventional density and resistance concrete, leaving aside the different possibilities offered by the market, such as lightweight concrete. This in turn leads to little information and quantified res...

Full description

Autores:
Viasús Arteaga, Carolina.
Tipo de recurso:
Fecha de publicación:
2019
Institución:
Escuela Colombiana de Ingeniería Julio Garavito
Repositorio:
Repositorio Institucional ECI
Idioma:
spa
OAI Identifier:
oai:repositorio.escuelaing.edu.co:001/1129
Acceso en línea:
https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=22291
https://repositorio.escuelaing.edu.co/handle/001/1129
Palabra clave:
Ingeniería de estructuras
Barras corrugadas - Acero post
Concreto
Anclajes ( Ingeniería de estructuras )
Structural Engineering
Corrugated bars - Steel post
Concrete
Anchors
Rights
openAccess
License
Derechos Reservados - Escuela Colombiana de Ingeniería Julio Garavito
id ESCUELAIG2_0cb2627a6b9006461f846acecf2f1b57
oai_identifier_str oai:repositorio.escuelaing.edu.co:001/1129
network_acronym_str ESCUELAIG2
network_name_str Repositorio Institucional ECI
repository_id_str
dc.title.spa.fl_str_mv Análisis del comportamiento de barras corrugadas de acero post-instaladas con adhesivo epóxico en concreto ligero sometidos a tensión y cortante :
title Análisis del comportamiento de barras corrugadas de acero post-instaladas con adhesivo epóxico en concreto ligero sometidos a tensión y cortante :
spellingShingle Análisis del comportamiento de barras corrugadas de acero post-instaladas con adhesivo epóxico en concreto ligero sometidos a tensión y cortante :
Ingeniería de estructuras
Barras corrugadas - Acero post
Concreto
Anclajes ( Ingeniería de estructuras )
Structural Engineering
Corrugated bars - Steel post
Concrete
Anchors
title_short Análisis del comportamiento de barras corrugadas de acero post-instaladas con adhesivo epóxico en concreto ligero sometidos a tensión y cortante :
title_full Análisis del comportamiento de barras corrugadas de acero post-instaladas con adhesivo epóxico en concreto ligero sometidos a tensión y cortante :
title_fullStr Análisis del comportamiento de barras corrugadas de acero post-instaladas con adhesivo epóxico en concreto ligero sometidos a tensión y cortante :
title_full_unstemmed Análisis del comportamiento de barras corrugadas de acero post-instaladas con adhesivo epóxico en concreto ligero sometidos a tensión y cortante :
title_sort Análisis del comportamiento de barras corrugadas de acero post-instaladas con adhesivo epóxico en concreto ligero sometidos a tensión y cortante :
dc.creator.fl_str_mv Viasús Arteaga, Carolina.
dc.contributor.advisor.spa.fl_str_mv Quiroga Saavedra, Pedro Nel ( dir)
dc.contributor.author.spa.fl_str_mv Viasús Arteaga, Carolina.
dc.subject.spa.fl_str_mv Ingeniería de estructuras
Barras corrugadas - Acero post
Concreto
Anclajes ( Ingeniería de estructuras )
topic Ingeniería de estructuras
Barras corrugadas - Acero post
Concreto
Anclajes ( Ingeniería de estructuras )
Structural Engineering
Corrugated bars - Steel post
Concrete
Anchors
dc.subject.keywords.spa.fl_str_mv Structural Engineering
Corrugated bars - Steel post
Concrete
Anchors
description In the country and in general in the world, the study of post-installed anchors has been limited to conventional density and resistance concrete, leaving aside the different possibilities offered by the market, such as lightweight concrete. This in turn leads to little information and quantified research about structural behavior in light concrete. Due to the above, an experimental program was proposed in which the behavior of corrugated bars anchored in light concrete was analyzed, for this, 7 solid concrete slabs were built, in which 39 corrugated bars were anchored, 33 of these anchors were tension tested, while the remaining six bars were shear tested. The results obtained from these tests were compared with the equations that determine the theoretical resistance of the anchors, as well as the expected failure modality of the same before different geometric and material arrangements. It was observed that for the tests confined to tension the predominant fault is presented in the epoxy and the shear tests have a specific failure. For the unconfined trials it was concluded that the predominant fault was in the concrete, in addition the clarification was made that it is necessary to respect the distance to the edge of the mines established by the ACI 318s-14 Chapter 17, since not doing so the calculations will present significant Differences than expected.
publishDate 2019
dc.date.issued.spa.fl_str_mv 2019
dc.date.accessioned.spa.fl_str_mv 2020-02-17T14:14:25Z
dc.date.available.spa.fl_str_mv 2020-02-17T14:14:25Z
dc.date.accessioned.none.fl_str_mv 2021-10-01T15:30:26Z
dc.date.available.none.fl_str_mv 2021-10-01T15:30:26Z
dc.type.spa.fl_str_mv Trabajo de grado - Maestría
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.content.spa.fl_str_mv Text
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/masterThesis
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/TM
status_str publishedVersion
dc.identifier.uri.spa.fl_str_mv https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=22291
dc.identifier.uri.none.fl_str_mv https://repositorio.escuelaing.edu.co/handle/001/1129
url https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=22291
https://repositorio.escuelaing.edu.co/handle/001/1129
dc.language.iso.spa.fl_str_mv spa
language spa
dc.rights.spa.fl_str_mv Derechos Reservados - Escuela Colombiana de Ingeniería Julio Garavito
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.uri.spa.fl_str_mv https://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.creativecommons.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)
rights_invalid_str_mv Derechos Reservados - Escuela Colombiana de Ingeniería Julio Garavito
https://creativecommons.org/licenses/by-nc/4.0/
Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Escuela Colombiana de Ingeniería Julio Garavito
dc.publisher.program.spa.fl_str_mv Maestría en Ingeniería Civil con Énfasis en Estructuras
institution Escuela Colombiana de Ingeniería Julio Garavito
bitstream.url.fl_str_mv https://repositorio.escuelaing.edu.co/bitstream/001/1129/1/Vias%c3%bas%20Arteaga%2c%20Carolina.-2019.pdf
https://repositorio.escuelaing.edu.co/bitstream/001/1129/2/Autorizaci%c3%b3n%20.pdf
https://repositorio.escuelaing.edu.co/bitstream/001/1129/3/license.txt
https://repositorio.escuelaing.edu.co/bitstream/001/1129/6/Vias%c3%bas%20Arteaga%2c%20Carolina.-2019.pdf.txt
https://repositorio.escuelaing.edu.co/bitstream/001/1129/8/Autorizaci%c3%b3n%20.pdf.txt
https://repositorio.escuelaing.edu.co/bitstream/001/1129/7/Vias%c3%bas%20Arteaga%2c%20Carolina.-2019.pdf.jpg
https://repositorio.escuelaing.edu.co/bitstream/001/1129/9/Autorizaci%c3%b3n%20.pdf.jpg
bitstream.checksum.fl_str_mv 84aac94059fdde41ce80c6fff9b47c47
6bba9f3307ee0c76cb2dc3633e6edbe5
5a7ca94c2e5326ee169f979d71d0f06e
aeabb9b76f42a99dfdb08530dc807f34
e1c06d85ae7b8b032bef47e42e4c08f9
613e39b64fbe211dda1e72223c9d25cf
87024f983c08f966d1eba7bf8ae85ad3
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Escuela Colombiana de Ingeniería Julio Garavito
repository.mail.fl_str_mv repositorio.eci@escuelaing.edu.co
_version_ 1814355633690902528
spelling Quiroga Saavedra, Pedro Nel ( dir)1583fae6403bd77e42a4bef426ee015eViasús Arteaga, Carolina.bf59d09078d135e3fd5ffd32e05fcaa26002020-02-17T14:14:25Z2021-10-01T15:30:26Z2020-02-17T14:14:25Z2021-10-01T15:30:26Z2019https://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=22291https://repositorio.escuelaing.edu.co/handle/001/1129In the country and in general in the world, the study of post-installed anchors has been limited to conventional density and resistance concrete, leaving aside the different possibilities offered by the market, such as lightweight concrete. This in turn leads to little information and quantified research about structural behavior in light concrete. Due to the above, an experimental program was proposed in which the behavior of corrugated bars anchored in light concrete was analyzed, for this, 7 solid concrete slabs were built, in which 39 corrugated bars were anchored, 33 of these anchors were tension tested, while the remaining six bars were shear tested. The results obtained from these tests were compared with the equations that determine the theoretical resistance of the anchors, as well as the expected failure modality of the same before different geometric and material arrangements. It was observed that for the tests confined to tension the predominant fault is presented in the epoxy and the shear tests have a specific failure. For the unconfined trials it was concluded that the predominant fault was in the concrete, in addition the clarification was made that it is necessary to respect the distance to the edge of the mines established by the ACI 318s-14 Chapter 17, since not doing so the calculations will present significant Differences than expected.En el país y en general en el mundo, el estudio de anclajes post-instalados, se ha limitado a concretos de densidad y resistencia convencionales dejando a un lado las diferentes posibilidades que ofrece el mercado, tales como concretos livianos. Esto lleva a su vez a poca información e investigación cuantificada acerca del comportamiento estructural en concretos ligeros. Debido a lo anterior, se planteó un programa experimental en el cual se analizó el comportamiento de barras corrugadas ancladas en concreto ligero, para esto, se construyeron 7 losas macizas de concreto, en las cuales se anclaron 39 barras corrugadas, 33 de estos anclajes fueron ensayados a tensión, mientras que las seis barras restantes se ensayaron a cortante. Los resultados obtenidos de estos ensayos fueron comparados con las ecuaciones que determinan la resistencia teórica de los anclajes, así como la modalidad de falla esperada de los mismos ante diferentes disposiciones geométricas y de materiales. Se pudo observar que para los ensayos confinados a tensión la falla predominante se presenta en el epóxico y los ensayos a cortante presenta fallo en concreto. Para los ensayos no confinados se concluyó que la falla predominante fue en el concreto, además se realizó la aclaración de que es necesario respetar las distancias al borde mininas establecidas por el ACI 318s-14 Capítulo 17, ya que al no hacerlo los cálculos presentaran significativas diferencias a lo esperado.MaestríaMagíster en Ingeniería Civil con Énfasis en Estructurasapplication/pdfspaEscuela Colombiana de Ingeniería Julio GaravitoMaestría en Ingeniería Civil con Énfasis en EstructurasDerechos Reservados - Escuela Colombiana de Ingeniería Julio Garavitohttps://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccessAtribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)http://purl.org/coar/access_right/c_abf2Ingeniería de estructurasBarras corrugadas - Acero postConcretoAnclajes ( Ingeniería de estructuras )Structural EngineeringCorrugated bars - Steel postConcreteAnchorsAnálisis del comportamiento de barras corrugadas de acero post-instaladas con adhesivo epóxico en concreto ligero sometidos a tensión y cortante :Trabajo de grado - Maestríainfo:eu-repo/semantics/publishedVersionTextinfo:eu-repo/semantics/masterThesishttp://purl.org/redcol/resource_type/TMhttp://purl.org/coar/version/c_970fb48d4fbd8a85ORIGINALViasús Arteaga, Carolina.-2019.pdfapplication/pdf5707810https://repositorio.escuelaing.edu.co/bitstream/001/1129/1/Vias%c3%bas%20Arteaga%2c%20Carolina.-2019.pdf84aac94059fdde41ce80c6fff9b47c47MD51open accessAutorización .pdfapplication/pdf1979003https://repositorio.escuelaing.edu.co/bitstream/001/1129/2/Autorizaci%c3%b3n%20.pdf6bba9f3307ee0c76cb2dc3633e6edbe5MD52metadata only accessLICENSElicense.txttext/plain1881https://repositorio.escuelaing.edu.co/bitstream/001/1129/3/license.txt5a7ca94c2e5326ee169f979d71d0f06eMD53open accessTEXTViasús Arteaga, Carolina.-2019.pdf.txtViasús Arteaga, Carolina.-2019.pdf.txtExtracted texttext/plain142571https://repositorio.escuelaing.edu.co/bitstream/001/1129/6/Vias%c3%bas%20Arteaga%2c%20Carolina.-2019.pdf.txtaeabb9b76f42a99dfdb08530dc807f34MD56open accessAutorización .pdf.txtAutorización .pdf.txtExtracted texttext/plain2https://repositorio.escuelaing.edu.co/bitstream/001/1129/8/Autorizaci%c3%b3n%20.pdf.txte1c06d85ae7b8b032bef47e42e4c08f9MD58metadata only accessTHUMBNAILViasús Arteaga, Carolina.-2019.pdf.jpgViasús Arteaga, Carolina.-2019.pdf.jpgGenerated Thumbnailimage/jpeg7020https://repositorio.escuelaing.edu.co/bitstream/001/1129/7/Vias%c3%bas%20Arteaga%2c%20Carolina.-2019.pdf.jpg613e39b64fbe211dda1e72223c9d25cfMD57open accessAutorización .pdf.jpgAutorización .pdf.jpgGenerated Thumbnailimage/jpeg14283https://repositorio.escuelaing.edu.co/bitstream/001/1129/9/Autorizaci%c3%b3n%20.pdf.jpg87024f983c08f966d1eba7bf8ae85ad3MD59metadata only access001/1129oai:repositorio.escuelaing.edu.co:001/11292021-10-01 17:42:17.88open accessRepositorio Escuela Colombiana de Ingeniería Julio Garavitorepositorio.eci@escuelaing.edu.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