A comparative surface analysis of explanted hip joint prostheses made of different biomedical alloys
The introduction of modular design in total hip arthroplasty has enabled the use of different materials in one single configuration and the adjustment of the prosthesis to the patient’s body, and facilitated medical revisions. However, modularity leads to the presence of new interfaces created betwe...
- Autores:
-
Bermúdez-Castañeda, Angela
Esguerra Arce, Johanna
Esguerra Arce, Adriana
Vargas-Pabón, Sofia Valentina
Ortiz-Martínez, Juan Guillermo
Blanco-Estupiñán, David Leonardo
Castaño, Juan Guillermo
Mischler, Stefano
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2021
- Institución:
- Escuela Colombiana de Ingeniería Julio Garavito
- Repositorio:
- Repositorio Institucional ECI
- Idioma:
- eng
- OAI Identifier:
- oai:repositorio.escuelaing.edu.co:001/3331
- Acceso en línea:
- https://repositorio.escuelaing.edu.co/handle/001/3331
https://repositorio.escuelaing.edu.co/
- Palabra clave:
- Steel
Acero
Electrochemistry
Electroquímica
Biomedical sciences
Ciencias biomédicas
Retrieval explants
Tribocorrosion
Modular hip joint implants
wear
Corrosión
Explantes
Modulares de cadera
Desgaste
- Rights
- closedAccess
- License
- http://purl.org/coar/access_right/c_14cb
Summary: | The introduction of modular design in total hip arthroplasty has enabled the use of different materials in one single configuration and the adjustment of the prosthesis to the patient’s body, and facilitated medical revisions. However, modularity leads to the presence of new interfaces created between pieces in contact, raising the issue of degradation. Tribocorrosion phenomena have been identified as the main degradation mechanism due to the mechanical, chemical, and electrochemical conditions acting on the materials. In addition, conditions inside the human body are unclear, regarding electrochemical settings and the interaction between the electrochemical and mechanical action. This work is focused on the degradation of monopolar hip joint implants made from biomedical alloys such as stainless steel, Ti, and CoCr alloys. Three cases are presented and analyzed in terms of the degradation level along the trunnion length. Surface analysis done on a titanium trunnion showed a significant ploughing on the distal part, compared to what was found for stainless steel and cobalt-chromium alloys, which can produce a stuck in this area. Meanwhile, in the proximal part, wear debris is found, which suggests more movement in the internal part. Although few debris particles were identified in CoCr trunnion, a large amount of material inside the contact was observed. This could be related to the ploughing generated in the distal thread pattern, which allowed the material to come inside and outside the contact. |
---|