Use of near-infrared spectroscopy in the neonatal intensive care unit
Near-infrared spectroscopy was first described in 1977 as a non-invasive technique to measure the cerebral oxygenation and cytochrome oxydase. Different techniques have been developed resulting in new instruments that make it possible to measure cerebral oxygenation in a non-invasive way. In this ch...
- Autores:
- Tipo de recurso:
- Fecha de publicación:
- 2012
- Institución:
- Universidad del Rosario
- Repositorio:
- Repositorio EdocUR - U. Rosario
- Idioma:
- eng
- OAI Identifier:
- oai:repository.urosario.edu.co:10336/28879
- Acceso en línea:
- https//doi 10.4018/978-1-4666-0975-4.ch004
https://repository.urosario.edu.co/handle/10336/28879
- Palabra clave:
- Near-infrared spectroscopy
Technique to measure
Cerebral oxygenation
Cytochrome oxydase
- Rights
- License
- Restringido (Acceso a grupos específicos)
id |
EDOCUR2_98c6e17aedeea3405dc47e0716ce033d |
---|---|
oai_identifier_str |
oai:repository.urosario.edu.co:10336/28879 |
network_acronym_str |
EDOCUR2 |
network_name_str |
Repositorio EdocUR - U. Rosario |
repository_id_str |
|
spelling |
1413951260038de6b05-427b-4843-8821-5161b28c7324-194f23f75-02c2-4bdf-be25-b1e6c9a34047-12020-08-28T15:49:59Z2020-08-28T15:49:59Z2012Near-infrared spectroscopy was first described in 1977 as a non-invasive technique to measure the cerebral oxygenation and cytochrome oxydase. Different techniques have been developed resulting in new instruments that make it possible to measure cerebral oxygenation in a non-invasive way. In this chapter the physiology and pathophysiology in relation to the measurement of cerebral oxygenation are explained and the direct possible clinical use enlightened, with special focus on measurement of ischemic cerebral hypoxia. The measurement of other organs like the liver, the bowel and the peripheral circulation are described. At the end, a short overview of future possible bed-side measurements like functional near-infrared spectroscopy, near-infrared imaging and photoacoustic measurements are given.application/pdfhttps//doi 10.4018/978-1-4666-0975-4.ch004ISBN: 978-1466609754https://repository.urosario.edu.co/handle/10336/28879engIGI GlobalNeonatal Monitoring Technologies: Design for Integrated SolutionsNeonatal Monitoring Technologies: Design for Integrated Solutions, ISBN: 978-1466609754 (2012); 28 pp.https://www.igi-global.com/chapter/content/65265Restringido (Acceso a grupos específicos)http://purl.org/coar/access_right/c_16ecNeonatal Monitoring Technologies: Design for Integrated Solutionsinstname:Universidad del Rosarioreponame:Repositorio Institucional EdocURNear-infrared spectroscopyTechnique to measureCerebral oxygenationCytochrome oxydaseUse of near-infrared spectroscopy in the neonatal intensive care unitUso de espectroscopia de infrarrojo cercano en la unidad de cuidados intensivos neonatalesbookPartParte de librohttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_3248Caicedo Dorado, AlexanderNaulaers, GVan Huffel10336/28879oai:repository.urosario.edu.co:10336/288792021-06-03 00:49:42.586https://repository.urosario.edu.coRepositorio institucional EdocURedocur@urosario.edu.co |
dc.title.spa.fl_str_mv |
Use of near-infrared spectroscopy in the neonatal intensive care unit |
dc.title.TranslatedTitle.spa.fl_str_mv |
Uso de espectroscopia de infrarrojo cercano en la unidad de cuidados intensivos neonatales |
title |
Use of near-infrared spectroscopy in the neonatal intensive care unit |
spellingShingle |
Use of near-infrared spectroscopy in the neonatal intensive care unit Near-infrared spectroscopy Technique to measure Cerebral oxygenation Cytochrome oxydase |
title_short |
Use of near-infrared spectroscopy in the neonatal intensive care unit |
title_full |
Use of near-infrared spectroscopy in the neonatal intensive care unit |
title_fullStr |
Use of near-infrared spectroscopy in the neonatal intensive care unit |
title_full_unstemmed |
Use of near-infrared spectroscopy in the neonatal intensive care unit |
title_sort |
Use of near-infrared spectroscopy in the neonatal intensive care unit |
dc.subject.keyword.spa.fl_str_mv |
Near-infrared spectroscopy Technique to measure Cerebral oxygenation Cytochrome oxydase |
topic |
Near-infrared spectroscopy Technique to measure Cerebral oxygenation Cytochrome oxydase |
description |
Near-infrared spectroscopy was first described in 1977 as a non-invasive technique to measure the cerebral oxygenation and cytochrome oxydase. Different techniques have been developed resulting in new instruments that make it possible to measure cerebral oxygenation in a non-invasive way. In this chapter the physiology and pathophysiology in relation to the measurement of cerebral oxygenation are explained and the direct possible clinical use enlightened, with special focus on measurement of ischemic cerebral hypoxia. The measurement of other organs like the liver, the bowel and the peripheral circulation are described. At the end, a short overview of future possible bed-side measurements like functional near-infrared spectroscopy, near-infrared imaging and photoacoustic measurements are given. |
publishDate |
2012 |
dc.date.created.spa.fl_str_mv |
2012 |
dc.date.accessioned.none.fl_str_mv |
2020-08-28T15:49:59Z |
dc.date.available.none.fl_str_mv |
2020-08-28T15:49:59Z |
dc.type.eng.fl_str_mv |
bookPart |
dc.type.coarversion.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_3248 |
dc.type.spa.spa.fl_str_mv |
Parte de libro |
dc.identifier.doi.none.fl_str_mv |
https//doi 10.4018/978-1-4666-0975-4.ch004 |
dc.identifier.issn.none.fl_str_mv |
ISBN: 978-1466609754 |
dc.identifier.uri.none.fl_str_mv |
https://repository.urosario.edu.co/handle/10336/28879 |
url |
https//doi 10.4018/978-1-4666-0975-4.ch004 https://repository.urosario.edu.co/handle/10336/28879 |
identifier_str_mv |
ISBN: 978-1466609754 |
dc.language.iso.spa.fl_str_mv |
eng |
language |
eng |
dc.relation.citationTitle.none.fl_str_mv |
Neonatal Monitoring Technologies: Design for Integrated Solutions |
dc.relation.ispartof.spa.fl_str_mv |
Neonatal Monitoring Technologies: Design for Integrated Solutions, ISBN: 978-1466609754 (2012); 28 pp. |
dc.relation.uri.spa.fl_str_mv |
https://www.igi-global.com/chapter/content/65265 |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_16ec |
dc.rights.acceso.spa.fl_str_mv |
Restringido (Acceso a grupos específicos) |
rights_invalid_str_mv |
Restringido (Acceso a grupos específicos) http://purl.org/coar/access_right/c_16ec |
dc.format.mimetype.none.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
IGI Global |
dc.source.spa.fl_str_mv |
Neonatal Monitoring Technologies: Design for Integrated Solutions |
institution |
Universidad del Rosario |
dc.source.instname.none.fl_str_mv |
instname:Universidad del Rosario |
dc.source.reponame.none.fl_str_mv |
reponame:Repositorio Institucional EdocUR |
repository.name.fl_str_mv |
Repositorio institucional EdocUR |
repository.mail.fl_str_mv |
edocur@urosario.edu.co |
_version_ |
1814167538645336064 |