Frequency of anesthetic overdose with mean alveolar concentration-guided anesthesia at high altitude

This study reported the frequency of anesthetic overdose measured with the bispectral index in a high altitude city (Bogotá-Colombia, 2600 meters above sea level). We assembled a prospective cohort of patients. Preoperative variables were described, and 10 minutes after the surgical incision, bispec...

Full description

Autores:
Tipo de recurso:
Fecha de publicación:
2018
Institución:
Universidad del Rosario
Repositorio:
Repositorio EdocUR - U. Rosario
Idioma:
eng
OAI Identifier:
oai:repository.urosario.edu.co:10336/22568
Acceso en línea:
https://doi.org/10.4103/2045-9912.248265
https://repository.urosario.edu.co/handle/10336/22568
Palabra clave:
Anesthetic agent
Sevoflurane
Adult
Age
Altitude
Article
Bispectral index
Clinical article
Cohort analysis
Colombia
Drug intoxication
Drug overdose
Female
General anesthesia
Human
Inhalation anesthesia
Intraoperative awareness
Male
Mean alveolar concentration
Mean arterial pressure
Oxygen saturation
Patient safety
Priority journal
Prospective study
Respiratory tract parameters
General anesthesia
Drug overdose
Biespectral index
Mean alveolar concentration
Altitude
Inhalation
Intraoperative awareness
Rights
License
Abierto (Texto Completo)
Description
Summary:This study reported the frequency of anesthetic overdose measured with the bispectral index in a high altitude city (Bogotá-Colombia, 2600 meters above sea level). We assembled a prospective cohort of patients. Preoperative variables were described, and 10 minutes after the surgical incision, bispectral index, mean alveolar concentration, mean arterial pressure, and oxygen saturation were recorded. Bispectral index was classified as superficial (60), adequate (40-60), and deep (> 40). Mean alveolar concentration was classified as low ( less than 0.8), normal (0.8-1.2), and high (> 1.2). We included 50 patients. The mean age of the patients was 36.3 ± 13.5 years; 48% were male and 78% were categorized as ASA I. Mean values of mean alveolar concentration and bispectral index were 1.14 ± 0.18 and 38.66 ± 6.9, respectively. Frequency of anesthetic overdose measured with bispectral index was 54% and only 20% with mean alveolar concentration. In total, 78% of patients received normal mean alveolar concentration values, and among these patients, 49% had deep bispectral index levels and 51% were adequate. There was no correlation between mean alveolar concentration and bispectral index (Pearson r = 0.161, P = 0.246) or between bispectral index and mean arterial pressure (Pearson r = 0.367, P = 0.08). All patients older than 60 years exhibited deep bispectral index levels, and although we did not identify a correlation between age and bispectral index, a tendency was observed (Pearson r = -0.087, P = 0.538). Safe and effective anesthesia overdose could be a common phenomenon. Bispectral index-guided anesthesia could be a helpful and reliable tool in the assessment and prevention of anesthesia overdose at high altitude. The study was approved by the ethics committee of the Fundación Cardioinfantil-Instituto de cardiología, Bogota, Colombia (approved number: 312017). © 2019 Medical Gas Research Published by Wolters Kluwer - Medknow.