Comparison of effectiveness between a conventional catheter and a manual commercial catheter: randomized trial of simulation of intraosseous access in a biological model

Introduction: In the emergency services an action of paramount importance in critically ill patients is to obtain an early vascular access. When vascular access is not established, an intraosseous route should be obtained; otherwise, the mortality of these critically ill patients is almost 100%. In...

Full description

Autores:
Tipo de recurso:
Fecha de publicación:
2019
Institución:
Universidad del Rosario
Repositorio:
Repositorio EdocUR - U. Rosario
Idioma:
eng
OAI Identifier:
oai:repository.urosario.edu.co:10336/23737
Acceso en línea:
https://doi.org/10.1097/CJ9.0000000000000101
https://repository.urosario.edu.co/handle/10336/23737
Palabra clave:
Adult
Article
Biological model
Cardiovascular procedure
Comparative effectiveness
Female
Hemispheric dominance
Human
Interosseous access
Male
Medical device complication
Metatarsal bone
Nonhuman
Surgery
Tarsal bone
Work experience
Clinical trials as topic
Critical care
Efficacy
Infusions
Intraosseous
Vascular access devices
Rights
License
Abierto (Texto Completo)
Description
Summary:Introduction: In the emergency services an action of paramount importance in critically ill patients is to obtain an early vascular access. When vascular access is not established, an intraosseous route should be obtained; otherwise, the mortality of these critically ill patients is almost 100%. In Colombia, the intraosseous access is not used because of the high costs of the devices and the lack of training of the healthcare staff to conduct the procedure.Objective: To determine the efficacy of a low-cost device to establish intraosseous access.Materials and methods: Quantitative approach, experimental design in a simulated environment with chicken tarsus and metatarsus. An analysis was conducted using frequency tables and central tendency measurements. Likewise, further analyses were done using Fisher's exact test, Chi2, and Mann-Whitney test.Results: A total of 99% of the procedures were successful with both catheters. The average time for intraosseous access was 6.6 seconds with Insyte 14 catheter and 4.7 seconds with Din 1515x Illinois Desch device (P=0.001). There were no significant differences in the number of attempts to secure a successful intraosseous access using any of the 2 devices (P=0.56).Conclusion: There was no significant difference between the Ci 14 and the Si 14 catheter to establish a successful intraosseous access in the chicken tarsus and metatarsus in a simulated environment. © 2019 Sociedad Colombiana de Anestesiología y Reanimación (S.C.A.R.E.).