Techno-environmental assessment of a micro-cogeneration system based on natural gas for residential application

The advantage of using in-situ electricity generation facilities versus conventional generators, being evaluated from the environmental point of view, was studied. For this, an environmental analysis on the production of CO2 has been applied to two scenarios of electricity generation for a residenti...

Full description

Autores:
Colmenares Quintero, Ramón Fernando
Latorre Noguera, Luis Fernando
Colmenares Quintero, Juan Carlos
Dibdiakova, Janka
Tipo de recurso:
Article of journal
Fecha de publicación:
2018
Institución:
Universidad Cooperativa de Colombia
Repositorio:
Repositorio UCC
Idioma:
OAI Identifier:
oai:repository.ucc.edu.co:20.500.12494/42990
Acceso en línea:
https://doi.org/10.7705/biomedica.v37i2.2893
https://www.scopus.com/inward/record.uri?eid=2-s2.0-78650454208&doi=10.3233%2fNRE-2010-0614&partnerID=40&md5=35b56b2b003663f09f626e1acf25ae1e
https://hdl.handle.net/20.500.12494/42990
Palabra clave:
building
carbon dioxide
cogeneration
electricity generation
energy use
environmental assessment
fossil fuel
greenhouse effect
natural gas
numerical model
power plant
residential energy
scenario analysis
software
Antioquia [Colombia]
Colombia
Medellin
Rights
closedAccess
License
http://purl.org/coar/access_right/c_14cb
id COOPER2_0a08fda29835e49cb1d3f2be6f563932
oai_identifier_str oai:repository.ucc.edu.co:20.500.12494/42990
network_acronym_str COOPER2
network_name_str Repositorio UCC
repository_id_str
spelling Colmenares Quintero, Ramón FernandoLatorre Noguera, Luis FernandoColmenares Quintero, Juan CarlosDibdiakova, Janka2021-12-16T22:16:39Z2021-12-16T22:16:39Z2018https://doi.org/10.7705/biomedica.v37i2.2893https://www.scopus.com/inward/record.uri?eid=2-s2.0-78650454208&doi=10.3233%2fNRE-2010-0614&partnerID=40&md5=35b56b2b003663f09f626e1acf25ae1e01225383https://hdl.handle.net/20.500.12494/42990COLMENARES R,LATORRE L,COLMENARES JC,Dibdiakova J. Techno-environmental assessment of a micro-cogeneration system based on natural gas for residential application. CT&F - CIENCIA, TECNOLOGÍA Y FUTURO. 2018. 8. (1):p. 101-112. .The advantage of using in-situ electricity generation facilities versus conventional generators, being evaluated from the environmental point of view, was studied. For this, an environmental analysis on the production of CO2 has been applied to two scenarios of electricity generation for a residential building in Medellin city (Colombia). First refers to La Sierra thermo-electric plant located in La Sierra, municipality of Puerto Nare, in the Antioquiashire, which is the most efficient plant in Colombian thermal generation. The second comparison scenario refers to the annual operation of a micro-cogeneration facility, which satisfies the building's hot water and electrical energy needs. Using the capabilities of the TRNSYS v17R energy simulation software and the emission equations available in the public domain, the comparative environmental analysis was performed between one and the other for the same load. The losses in electric transmission are assumed to be 10%. The analysis showed a difference of more than 50% in emissions generation, due mainly to the amount of fuel used, which for both cases, is natural gas. The environmental advantages in the use of in-situ generators include the decrease in transmission losses.0000-0003-1166-1982ramon.colmenaresq@campusucc.edu.co112-101Ecopetrolbuildingcarbon dioxidecogenerationelectricity generationenergy useenvironmental assessmentfossil fuelgreenhouse effectnatural gasnumerical modelpower plantresidential energyscenario analysissoftwareAntioquia [Colombia]ColombiaMedellinTechno-environmental assessment of a micro-cogeneration system based on natural gas for residential applicationArtículohttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articlehttp://purl.org/redcol/resource_type/ARTinfo:eu-repo/semantics/publishedVersionCT&F - CIENCIA, TECNOLOGÍA Y FUTUROinfo:eu-repo/semantics/closedAccesshttp://purl.org/coar/access_right/c_14cbPublication20.500.12494/42990oai:repository.ucc.edu.co:20.500.12494/429902024-08-20 16:21:19.514metadata.onlyhttps://repository.ucc.edu.coRepositorio Institucional Universidad Cooperativa de Colombiabdigital@metabiblioteca.com
dc.title.spa.fl_str_mv Techno-environmental assessment of a micro-cogeneration system based on natural gas for residential application
title Techno-environmental assessment of a micro-cogeneration system based on natural gas for residential application
spellingShingle Techno-environmental assessment of a micro-cogeneration system based on natural gas for residential application
building
carbon dioxide
cogeneration
electricity generation
energy use
environmental assessment
fossil fuel
greenhouse effect
natural gas
numerical model
power plant
residential energy
scenario analysis
software
Antioquia [Colombia]
Colombia
Medellin
title_short Techno-environmental assessment of a micro-cogeneration system based on natural gas for residential application
title_full Techno-environmental assessment of a micro-cogeneration system based on natural gas for residential application
title_fullStr Techno-environmental assessment of a micro-cogeneration system based on natural gas for residential application
title_full_unstemmed Techno-environmental assessment of a micro-cogeneration system based on natural gas for residential application
title_sort Techno-environmental assessment of a micro-cogeneration system based on natural gas for residential application
dc.creator.fl_str_mv Colmenares Quintero, Ramón Fernando
Latorre Noguera, Luis Fernando
Colmenares Quintero, Juan Carlos
Dibdiakova, Janka
dc.contributor.author.none.fl_str_mv Colmenares Quintero, Ramón Fernando
Latorre Noguera, Luis Fernando
Colmenares Quintero, Juan Carlos
Dibdiakova, Janka
dc.subject.spa.fl_str_mv building
carbon dioxide
cogeneration
electricity generation
energy use
environmental assessment
fossil fuel
greenhouse effect
natural gas
numerical model
power plant
residential energy
scenario analysis
software
Antioquia [Colombia]
Colombia
Medellin
topic building
carbon dioxide
cogeneration
electricity generation
energy use
environmental assessment
fossil fuel
greenhouse effect
natural gas
numerical model
power plant
residential energy
scenario analysis
software
Antioquia [Colombia]
Colombia
Medellin
description The advantage of using in-situ electricity generation facilities versus conventional generators, being evaluated from the environmental point of view, was studied. For this, an environmental analysis on the production of CO2 has been applied to two scenarios of electricity generation for a residential building in Medellin city (Colombia). First refers to La Sierra thermo-electric plant located in La Sierra, municipality of Puerto Nare, in the Antioquiashire, which is the most efficient plant in Colombian thermal generation. The second comparison scenario refers to the annual operation of a micro-cogeneration facility, which satisfies the building's hot water and electrical energy needs. Using the capabilities of the TRNSYS v17R energy simulation software and the emission equations available in the public domain, the comparative environmental analysis was performed between one and the other for the same load. The losses in electric transmission are assumed to be 10%. The analysis showed a difference of more than 50% in emissions generation, due mainly to the amount of fuel used, which for both cases, is natural gas. The environmental advantages in the use of in-situ generators include the decrease in transmission losses.
publishDate 2018
dc.date.issued.none.fl_str_mv 2018
dc.date.accessioned.none.fl_str_mv 2021-12-16T22:16:39Z
dc.date.available.none.fl_str_mv 2021-12-16T22:16:39Z
dc.type.none.fl_str_mv Artículo
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.coar.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.none.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driver.none.fl_str_mv info:eu-repo/semantics/article
dc.type.redcol.none.fl_str_mv http://purl.org/redcol/resource_type/ART
dc.type.version.none.fl_str_mv info:eu-repo/semantics/publishedVersion
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.none.fl_str_mv https://doi.org/10.7705/biomedica.v37i2.2893
https://www.scopus.com/inward/record.uri?eid=2-s2.0-78650454208&doi=10.3233%2fNRE-2010-0614&partnerID=40&md5=35b56b2b003663f09f626e1acf25ae1e
dc.identifier.issn.spa.fl_str_mv 01225383
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12494/42990
dc.identifier.bibliographicCitation.spa.fl_str_mv COLMENARES R,LATORRE L,COLMENARES JC,Dibdiakova J. Techno-environmental assessment of a micro-cogeneration system based on natural gas for residential application. CT&F - CIENCIA, TECNOLOGÍA Y FUTURO. 2018. 8. (1):p. 101-112. .
url https://doi.org/10.7705/biomedica.v37i2.2893
https://www.scopus.com/inward/record.uri?eid=2-s2.0-78650454208&doi=10.3233%2fNRE-2010-0614&partnerID=40&md5=35b56b2b003663f09f626e1acf25ae1e
https://hdl.handle.net/20.500.12494/42990
identifier_str_mv 01225383
COLMENARES R,LATORRE L,COLMENARES JC,Dibdiakova J. Techno-environmental assessment of a micro-cogeneration system based on natural gas for residential application. CT&F - CIENCIA, TECNOLOGÍA Y FUTURO. 2018. 8. (1):p. 101-112. .
dc.relation.ispartofjournal.spa.fl_str_mv CT&F - CIENCIA, TECNOLOGÍA Y FUTURO
dc.rights.accessrights.none.fl_str_mv info:eu-repo/semantics/closedAccess
dc.rights.coar.none.fl_str_mv http://purl.org/coar/access_right/c_14cb
eu_rights_str_mv closedAccess
rights_invalid_str_mv http://purl.org/coar/access_right/c_14cb
dc.format.extent.spa.fl_str_mv 112-101
dc.publisher.spa.fl_str_mv Ecopetrol
institution Universidad Cooperativa de Colombia
repository.name.fl_str_mv Repositorio Institucional Universidad Cooperativa de Colombia
repository.mail.fl_str_mv bdigital@metabiblioteca.com
_version_ 1814247138190688256